510(k) Report

510(k) · Cleared

Cleared

Raven Protest - Steam Biological Indicator

K082756510(k) TraditionalCleared Oct 21, 2009397-day reviewClass II21 CFR 880.2800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Raven Biological Laboratories, Inc. · FRC Indicator, Biological Sterilization Process

Cleared on Oct 21, 2009 as substantially equivalent to K041386 (Raven Biological Laboratories, Inc., 2004) after a 397-day review. Its family tree reaches back 3 generations to 1980. 1 later device descends from it.

Decided
Oct 21, 2009
Review
397 days
Class
Class II
Product code
FRC
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K801109 (1980). 5 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1994: 1 other ancestor1990: 1 other ancestor2012: 1 descendant clearedK801109 · Proof (Biological/Chemical Indicator) · Amsco Co. · 1980K963841 · Eztest · Sgm Biotech, Inc. · 1997 · recalledK041386 · Raven Protest - Steam · Raven Biological Laboratories, Inc. · 200419801990200020102020
Other ancestors, by generationDescendants, by generation 3 generations back: 2 other ancestors 1 generation forward: 1 descendant K041386 · Raven Protest - Steam · Raven Biological Laboratories, Inc. · 2004K963841 · Eztest · Sgm Biotech, Inc. · 1997 · recalledK801109 · Proof (Biological/Chemical Indicator) · Amsco Co. · 19800
  1. Root · 3 generations backK801109 Proof (Biological/Chemical Indicator)Amsco Co. · 1980
  2. 2 generations backK963841 EztestSgm Biotech, Inc. · 1997 · Recalled
  3. 1 generation backK041386 Raven Protest - SteamRaven Biological Laboratories, Inc. · 2004
  4. This deviceK082756 Raven Protest - Steam Biological IndicatorRaven Biological Laboratories, Inc. · 2009
  5. Descendant · cites it directly · 0 of its ownK112018 Smart Read Eztest SteamMesa Laboratories, Inc. · 2012

Most influential descendants

Showing 1 of 1 · See all
  • K112018Smart Read Eztest SteamMesa Laboratories, Inc. · 2012 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K801109Proof (Biological/Chemical Indicator)Amsco Co.1980—
−2K963841EztestSgm Biotech, Inc.19971
−1K041386Raven Protest - SteamRaven Biological Laboratories, Inc.2004—
0 (this device)K082756Raven Protest - Steam Biological IndicatorRaven Biological Laboratories, Inc.2009—
+1K112018Smart Read Eztest SteamMesa Laboratories, Inc.2012—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
199410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
FIG. 1 — Lineage of K082756, 1980–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FRC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRC device

  1. #1 K250044 Celerity 5 HP Biological Indicator (LCB052)…score 14.5 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K041386Raven Protest - Steam
Summary page 1
…Indicator for Steam Classification: Class II Predicate Device: ProTest Steam (K041386) DESCRIPTION The biological indicator consists of a self-contained unit that includes bacterial spores of Geobacillus stearothe…
Raven Biological Laboratories, Inc.2004—

Also cleared against K041386: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K112018Smart Read Eztest SteamMesa Laboratories, Inc.20120

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 29 years and passes through 3 companies; a new generation was cleared every 7.5 years on median.
  • 2 of the 5 ancestors have a recall of any class.
  • Of its descendants, K112018 (Mesa Laboratories, Inc., 2012) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K041386.

How does its category compare?

All FRC devices

FRC Indicator, Biological Sterilization Process: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · FRC

6in 2025

2007: 32008: 12009: 62010: 42011: 62012: 92013: 42014: 132015: 32016: 22017: 102018: 182019: 52020: 102021: 52022: 52023: 62024: 82025: 62026 (partial year): 1
2007high 18 (2018) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRC

29in 2025

2007: 83 days median2009: 183 days median2010: 165 days median2011: 118 days median2012: 178 days median2013: 260 days median2014: 174 days median2015: 130 days median2017: 130 days median2018: 97 days median2019: 88 days median2020: 150 days median2021: 107 days median2022: 193 days median2023: 190 days median2024: 105 days median2025: 29 days median
2007high 260 (2013) · low 29 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRC

8so far in 2026, the most since 2007

2009: 12012: 22013: 22022: 42023: 12026 (partial year): 8
2007high 8 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FRC

9in 2025

2007: 1002008: 602009: 452010: 572011: 372012: 462013: 392014: 512015: 1822016: 4822017: 1822018: 222019: 302020: 162021: 102022: 92023: 202024: 222025: 9
2007high 482 (2016) · low 9 (2022)2025

MAUDE reports naming product code FRC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073830100
20081—060
20096183145
20104165057
20116118037
20129178246
20134260239
201413174051
201531300182
20162—0482
2017101300182
20181897022
2019588030
202010150016
20215107010
2022519349
20236190120
20248105022
202562909
20261—8—

What is it indicated for?

Raven ProTest Steam is a self-contained Biological Indicator inoculated with Geobacillus stearothermnophilus spores and is intended for monitoring the efficacy of steam sterilization cycles (10 minute 132°C gravity displacement and 3 minute 132 0C flash gravity displacement cycles). Raven ProTest has a validated reduced incubation time of 24 hours.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K082756: Raven Protest - Steam Biological Indicator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K082756

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026