Omron Model HBP-2070 Vital Signs Monitor

K082812510(k) SpecialCleared Oct 22, 200828-day reviewClass II21 CFR 870.2300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Omron Healthcare, Inc. · MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)

Cleared on Oct 22, 2008 as substantially equivalent to K973637 (Colin Medical Instruments Corp., 1998) and 2 other predicates after a 28-day review. Its family tree reaches back 4 generations to 1987. 27 later devices descend from it.

Decided
Oct 22, 2008
Review
28 days
Class
Class II
Product code
MWI
Recalls
None
Predicates
3

Its longest line of descent runs back 4 generations to K872291 (1987). 8 ancestors in all. 27 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2007: 1 other ancestor1993: 1 other ancestor1994: 1 other ancestor1989: 1 other ancestor2012: 2 descendants cleared2011: 1 descendant cleared2010: 1 descendant cleared2013: 2 descendants cleared2015: 6 descendants cleared2025: 3 descendants cleared2017: 1 descendant cleared2018: 5 descendants cleared2019: 2 descendants cleared2024: 1 descendant cleared2021: 1 descendant cleared2022: 1 descendant cleared2023: 1 descendant clearedK872291 · Escort Portable Patient Monitor · Medical Data Electronics · 1987K973637 · Press-Mate Advantage · Colin Medical Instruments Corp. · 1998K022537 · Press-Mate PM-2100 Vital Sign Monitor · Colin Medical Instruments Corp. · 2002K071645 · Model HBP T-105 Series, Model T-105 and T-105S · Omron Healthcare, Inc. · 20071990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 1 other ancestor3 generations back: 2 other ancestors 1 generation forward: 3 descendants2 generations forward: 3 descendants3 generations forward: 5 descendants4 generations forward: 3 descendants5 generations forward: 6 descendants6 generations forward: 4 descendants7 generations forward: 3 descendants K071645 · Model HBP T-105 Series, Model T-105 and T-105S · Omron Healthcare, Inc. · 2007K022537 · Press-Mate PM-2100 Vital Sign Monitor · Colin Medical Instruments Corp. · 2002K973637 · Press-Mate Advantage · Colin Medical Instruments Corp. · 1998K872291 · Escort Portable Patient Monitor · Medical Data Electronics · 19870+5
  1. Root · 4 generations backK872291 Escort Portable Patient MonitorMedical Data Electronics · 1987
  2. 3 generations backK973637 Press-Mate AdvantageColin Medical Instruments Corp. · 1998
  3. 2 generations backK022537 Press-Mate PM-2100 Vital Sign MonitorColin Medical Instruments Corp. · 2002
  4. 1 generation backK071645 Model HBP T-105 Series, Model T-105 and T-105SOmron Healthcare, Inc. · 2007
  5. This deviceK082812 Omron Model HBP-2070 Vital Signs MonitorOmron Healthcare, Inc. · 2008
  6. Descendant · cites it directly · 24 of its ownK112478 Visi Mobile Monitoring SystemSotera Wireless, Inc. · 2012 · Recalled
  7. Descendant · 2 generations on · 20 of its ownK122036 Visi Mobile Monitoring SystemSotera Wireless, Inc. · 2012 · Recalled
  8. Descendant · 2 generations on · 19 of its ownK130709 Visi Mobile Monitoring SystemSotera Wireless, Inc. · 2013
  9. Descendant · 3 generations on · 18 of its ownK133586 Visi Mobile Monitioring SystemSotera Wireless, Inc. · 2013
  10. Descendant · 3 generations on · 17 of its ownK143751 Visi Mobile Monitoring SystemSotera Wireless, Inc. · 2015

Showing 5 of 27 descendants. See all descendants

Descendants cleared per year

2010: 12011: 12012: 22013: 22015: 62017: 12018: 52019: 22021: 12022: 12023: 12024: 12025: 3
2010high 6 (2015) · low 0 (2014)2026

Most influential descendants

Showing 5 of 27 · See all
  • K112478Visi Mobile Monitoring SystemSotera Wireless, Inc. · 2012 · cites it directly24descendants
  • K122036Visi Mobile Monitoring SystemSotera Wireless, Inc. · 2012 · 2 generations on20descendants
  • K130709Visi Mobile Monitoring SystemSotera Wireless, Inc. · 2013 · 2 generations on19descendants
  • K133586Visi Mobile Monitioring SystemSotera Wireless, Inc. · 2013 · 3 generations on18descendants
  • K143751Visi Mobile Monitoring SystemSotera Wireless, Inc. · 2015 · 3 generations on17descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K872291Escort Portable Patient MonitorMedical Data Electronics1987—
−3K973637Press-Mate AdvantageColin Medical Instruments Corp.1998—
−2K022537Press-Mate PM-2100 Vital Sign MonitorColin Medical Instruments Corp.2002—
−1K071645Model HBP T-105 Series, Model T-105 and T-105SOmron Healthcare, Inc.2007—
0 (this device)K082812Omron Model HBP-2070 Vital Signs MonitorOmron Healthcare, Inc.2008—
+1K112478Visi Mobile Monitoring SystemSotera Wireless, Inc.20122
+2K122036Visi Mobile Monitoring SystemSotera Wireless, Inc.20122
+2K130709Visi Mobile Monitoring SystemSotera Wireless, Inc.2013—
+3K133586Visi Mobile Monitioring SystemSotera Wireless, Inc.2013—
+3K143751Visi Mobile Monitoring SystemSotera Wireless, Inc.2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199310
199410
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201110
201220
201320
201560
201710
201850
201920
202110
202210
202310
202410
202530
FIG. 1 — Lineage of K082812, 1987–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MWI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MWI device

  1. #1 K230457 Empatica Health Monitoring Platform…score 28.0 · 39 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K973637Press-Mate Advantage
Summary page 1
…- System, Measurement, Blood-pressure, Non-invasive Device: Model - HBP-2070 Predicate Devices: Omron - Press-Mate Advantage - K973637 Device Description: The proposed vital signs monitor is a modification of a previously cleared Colin Press Mate Advantage (K9736…
Colin Medical Instruments Corp.1998—
*K063690Colin Press Mate, Model BP S510
Summary page 4
…e Nellcor MP-203 Nellcor NELL-3 Predicate Oreon BP-S5 10 (K063690) Measurement method 2 wave length pulse wave type same as predicate device SpO2 display range…
Omron Healthcare, Inc.2007—
*K071645Model HBP T-105 Series, Model T-105 and T-105S
Summary page 3
…Pediatric / Neonatal) 30 -100 mmHg which has been used in our predicate DIA - Adult) 40- 200 mmHg HBP-TI05 (K071645) Pediatric / Neonatal) 20 -90 mmHg Pressure display range 10- 300 mmHg…
Omron Healthcare, Inc.2007—

Also cleared against K973637: 4 other devices →

What descends from it? (27)

See all 27

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K112478Visi Mobile Monitoring SystemSotera Wireless, Inc.201224
K100217Lucon M-Series Patient Monitor, Models M20 and M30Mediana Co., Ltd.20101
K112190Patient MonitorMediana Co., Ltd.20110

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 3 companies; a new generation was cleared every 4.8 years on median.
  • None of the 8 ancestors has a recall.
  • Of its descendants, K112478 (Sotera Wireless, Inc., 2012) has gone furthest, with 24 descendants of its own.
  • 4 other devices also cite its predicate K973637.

How does its category compare?

All MWI devices

MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years. 2008, this device’s year, is highlighted.

FDA decisions per year · MWI

4in 2025

2007: 92008: 92009: 62010: 172011: 112012: 132013: 202014: 162015: 192016: 122017: 132018: 112019: 142020: 82021: 92022: 52023: 82024: 102025: 42026 (partial year): 6
2007high 20 (2013) · low 4 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MWI

247in 2025

2007: 42 days median2008: 49 days median2009: 112 days median2010: 58 days median2011: 78 days median2012: 104 days median2013: 85 days median2014: 148 days median2015: 127 days median2016: 165 days median2017: 205 days median2018: 217 days median2019: 255 days median2020: 138 days median2021: 161 days median2022: 231 days median2023: 250 days median2024: 202 days median2025: 247 days median2026 (partial year): 239 days median
2007high 255 (2019) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MWI

9so far in 2026, the most since 2007

2007: 12008: 12009: 22010: 22011: 32012: 52013: 32014: 62015: 12017: 22019: 42022: 22024: 52026 (partial year): 9
2007high 9 (2026) · low 0 (2016)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MWI

182in 2025

2007: 32008: 32009: 202010: 172011: 162012: 312013: 422014: 302015: 312016: 512017: 852018: 1582019: 1692020: 1102021: 1882022: 1682023: 1792024: 1202025: 182
2007high 188 (2021) · low 3 (2007)2025

MAUDE reports naming product code MWI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200794213
200894913
20096112220
20101758217
20111178316
201213104531
20132085342
201416148630
201519127131
201612165051
201713205285
2018112170158
2019142554169
202081380110
202191610188
202252312168
202382500179
2024102025120
202542470182
202662399—

What is it indicated for?

The HBP-2070 is intended to be used to monitor electrocardiography (ECG),heart rate (HR), noninvasive blood pressure (systolic, diastolic and mean arterial pressure) (NIBP), functional arterial oxygen saturation (SpO 2), pulse rate (PR), respiration (RR) temperature (Temp) for adult, pediatric, and neonatal patients in all areas of a hospital and hospital-type facilities. Monitor users should be skilled at the level of a technician, doctor, nurse, or medical specialist.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K082812: Omron Model HBP-2070 Vital Signs Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K082812

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026