510(k) · Cleared
Recalled · Class II · 2020Intellivue Patient Monitor, Models MP2, MP5, MP20, MP30, MP40, MP50, MO60, MP7-, MP80, and MP90
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · DSI Detector And Alarm, Arrhythmia
Cleared on Jan 16, 2009 as substantially equivalent to K021778 (Philips Medical Systems, 2002) and 22 other predicates after a 51-day review. Its family tree reaches back 26 generations to 1994. 125 later devices descend from it. It has been recalled 2 times.
- Decided
- Jan 16, 2009
- Review
- 51 days
- Class
- Class II
- Product code
- DSI
- Recalls
- 2
- Predicates
- 23
Its longest line of descent runs back 26 generations to K941811 (1994). 172 ancestors in all, the oldest K844187 (1985). 125 later devices descend from it, 18 citing it directly.
- Root · 26 generations backK941811 HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co. · 1994
- 22 generations between
- 3 generations backK061610 Philips Model MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90…Philips Medizin Systeme Boeblingen GmbH · 2006
- 2 generations backK063315 Intellivue Patient Monitors, Models MP20, MP30, MP40, MP50, MP60…Philips Medizin Systeme Boeblingen GmbH · 2006
- 1 generation backK071426 MP2, X2, MP5, MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2007
- This deviceK083517 Intellivue Patient Monitor, Models MP2, MP5, MP20, MP30, MP40, MP50…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2009
- Descendant · cites it directly · 124 of its ownK091927 Intellivue Patient Monitors ,Models MP40, MP50, MP60, MP70, MP80, MP90Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2009
- Descendant · cites it directly · 123 of its ownK100939 Intellivue Patient Monitor Model: MP2, MP5, MP5T, MP20, MP30, MP40…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2010
- Descendant · cites it directly · 103 of its ownK102562 Intellivue Patient Monitor, Models MP2, X2, MP5, MP5T, MP20, MP30…Philips Medizin Systeme Boblingen GmbH · 2010
- Descendant · 2 generations on · 92 of its ownK101449 Intellivue Patient MonitorPhilips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2010
- Descendant · cites it directly · 90 of its ownK110622 Intellivue Patient MonitorPhilips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2011 · Recalled
Show all 26 generations
- Root · 26 generations backK941811 HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co. · 1994
- 25 generations backK960934 HP M1205A Omnicare Component Monitor System Model 24Hewlett-Packard Co. · 1996
- 24 generations backK981376 Hewlett-Packard M1205A Viridia 24 CTHewlett-Packard Co. · 1999
- 23 generations backK990125 HP Viridia Component Monitoring System, Model Rev. KHewlett-Packard GmbH · 1999
- 22 generations backK990972 HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP…Hewlett-Packard GmbH · 1999
- 21 generations backK013199 Philips Component Compact Monitor,Model M1275B, Philips Compenent…Philips Medical Systems, Inc. · 2001
- 20 generations backK020531 Philips Multi-Parameter Module, Model M3001A; Philips Component…Philips Medical Systems · 2002
- 19 generations backK021778 Philips Component Compact Monitor, Release a.04, Model #M1275BPhilips Medical Systems · 2002
- 18 generations backK023871 M3046A (M2/M3/M4) Compact Portable Patient Monitor and MP60 & MP70…Philips Medical Systems · 2002
- 17 generations backK030038 Philips MP60, MP70 and MP90 Intellivue Patient Monitors with Portal…Philips Medical Systems, Inc. · 2003
- 16 generations backK031481 The Philips Intellivue MP60, MP70, and MP90 Patient Monitors…Philips Medizin Systeme Boblingen GmbH · 2003
- 15 generations backK032858 The Philips Intellivue MP40, MP50, MP60, MP70,and MP90 Patient…Philips Medizin Systeme Boblingen GmbH · 2003
- 14 generations backK040304 Philips Intellivue Patient Monitor, Models MP40 & MP50Philips Medizin Systeme Boeblingen GmbH · 2004
- 13 generations backK041235 Philips MP20, MP30, MP40, MP50. MP60, MP70 and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH · 2004
- 12 generations backK042845 The Philips MP20, MP30, MP40, MP50, MP60, MP70, and MP90 Intellivue…Philips Medizin Systeme Boblingen GmbH · 2004
- 11 generations backK050141 The Philips MP20, MP30, MP40, MP50, MP60, MP70 and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH · 2005
- 10 generations backK050762 Philips Intellivue Patient Monitor, Models MP20, MP30, MP40, MP50…Philips Medizin Systeme Boeblingen GmbH · 2005
- 9 generations backK051106 The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90…Philips Medizin Systeme Boeblingen GmbH · 2005
- 8 generations backK052801 Intellivue Patient Monitors with Release C.02, Models MP20, MP30…Philips Medizin Systeme Boeblingen GmbH · 2005
- 7 generations backK053522 Philips MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient…Philips Medizin Systeme Boeblingen GmbH · 2006
- 6 generations backK060221 The Phillips, Model MP20,MP30,MP40,MP50,MP60,MP70,MP80,and MP90…Philips Medizin Systeme Boeblingen GmbH · 2006
- 5 generations backK060541 The Philips MP20,MP30,MP40,MP50,MP60,MP70,MP80 and MP90 Intellivue…Philips Medizin Systeme Boblingen GmbH · 2006 · Recalled
- 4 generations backK061052 The Philips Intellivue Patient Monitors, Models…Philips Medical Systems North America, Inc. · 2006
- 3 generations backK061610 Philips Model MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90…Philips Medizin Systeme Boeblingen GmbH · 2006
- 2 generations backK063315 Intellivue Patient Monitors, Models MP20, MP30, MP40, MP50, MP60…Philips Medizin Systeme Boeblingen GmbH · 2006
- 1 generation backK071426 MP2, X2, MP5, MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2007
- This deviceK083517 Intellivue Patient Monitor, Models MP2, MP5, MP20, MP30, MP40, MP50…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2009
Showing 5 of 125 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 125 · See all- K091927Intellivue Patient Monitors ,Models MP40, MP50, MP60, MP70, MP80, MP90Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2009 · cites it directly124descendants
- K100939Intellivue Patient Monitor Model: MP2, MP5, MP5T, MP20, MP30, MP40, MP50, MP60, MP70…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2010 · cites it directly123descendants
- K102562Intellivue Patient Monitor, Models MP2, X2, MP5, MP5T, MP20, MP30, MP40, MP50, MP60…Philips Medizin Systeme Boblingen GmbH · 2010 · cites it directly103descendants
- K101449Intellivue Patient MonitorPhilips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2010 · 2 generations on92descendants
- K110622Intellivue Patient MonitorPhilips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2011 · cites it directly90descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −26 | K941811 | HP M1175A, M1176A, Component Monitoring System | Hewlett-Packard Co. | 1994 | — |
| −25 | K960934 | HP M1205A Omnicare Component Monitor System Model 24 | Hewlett-Packard Co. | 1996 | — |
| −24 | K981376 | Hewlett-Packard M1205A Viridia 24 CT | Hewlett-Packard Co. | 1999 | — |
| −23 | K990125 | HP Viridia Component Monitoring System, Model Rev. K | Hewlett-Packard GmbH | 1999 | — |
| −22 | K990972 | HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP Viridia… | Hewlett-Packard GmbH | 1999 | — |
| −21 | K013199 | Philips Component Compact Monitor,Model M1275B, Philips Compenent Rack, Model… | Philips Medical Systems, Inc. | 2001 | — |
| −20 | K020531 | Philips Multi-Parameter Module, Model M3001A; Philips Component Compact… | Philips Medical Systems | 2002 | — |
| −19 | K021778 | Philips Component Compact Monitor, Release a.04, Model #M1275B | Philips Medical Systems | 2002 | — |
| −18 | K023871 | M3046A (M2/M3/M4) Compact Portable Patient Monitor and MP60 & MP70 Intellivue… | Philips Medical Systems | 2002 | — |
| −17 | K030038 | Philips MP60, MP70 and MP90 Intellivue Patient Monitors with Portal Technology… | Philips Medical Systems, Inc. | 2003 | — |
| −16 | K031481 | The Philips Intellivue MP60, MP70, and MP90 Patient Monitors, Release a.20 | Philips Medizin Systeme Boblingen GmbH | 2003 | — |
| −15 | K032858 | The Philips Intellivue MP40, MP50, MP60, MP70,and MP90 Patient Monitors… | Philips Medizin Systeme Boblingen GmbH | 2003 | — |
| −14 | K040304 | Philips Intellivue Patient Monitor, Models MP40 & MP50 | Philips Medizin Systeme Boeblingen GmbH | 2004 | — |
| −13 | K041235 | Philips MP20, MP30, MP40, MP50. MP60, MP70 and MP90 Intellivue Patient Monitors | Philips Medizin Systeme Boeblingen GmbH | 2004 | — |
| −12 | K042845 | The Philips MP20, MP30, MP40, MP50, MP60, MP70, and MP90 Intellivue Patient… | Philips Medizin Systeme Boblingen GmbH | 2004 | — |
| −11 | K050141 | The Philips MP20, MP30, MP40, MP50, MP60, MP70 and MP90 Intellivue Patient… | Philips Medizin Systeme Boeblingen GmbH | 2005 | — |
| −10 | K050762 | Philips Intellivue Patient Monitor, Models MP20, MP30, MP40, MP50, MP60, MP70… | Philips Medizin Systeme Boeblingen GmbH | 2005 | — |
| −9 | K051106 | The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue… | Philips Medizin Systeme Boeblingen GmbH | 2005 | — |
| −8 | K052801 | Intellivue Patient Monitors with Release C.02, Models MP20, MP30, MP40, MP50… | Philips Medizin Systeme Boeblingen GmbH | 2005 | — |
| −7 | K053522 | Philips MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient Monitors… | Philips Medizin Systeme Boeblingen GmbH | 2006 | — |
| −6 | K060221 | The Phillips, Model MP20,MP30,MP40,MP50,MP60,MP70,MP80,and MP90 Intellivue… | Philips Medizin Systeme Boeblingen GmbH | 2006 | — |
| −5 | K060541 | The Philips MP20,MP30,MP40,MP50,MP60,MP70,MP80 and MP90 Intellivue Atient… | Philips Medizin Systeme Boblingen GmbH | 2006 | 2 |
| −4 | K061052 | The Philips Intellivue Patient Monitors, Models… | Philips Medical Systems North America, Inc. | 2006 | — |
| −3 | K061610 | Philips Model MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue… | Philips Medizin Systeme Boeblingen GmbH | 2006 | — |
| −2 | K063315 | Intellivue Patient Monitors, Models MP20, MP30, MP40, MP50, MP60, MP70, MP80… | Philips Medizin Systeme Boeblingen GmbH | 2006 | — |
| −1 | K071426 | MP2, X2, MP5, MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90 Intellivue… | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2007 | — |
| 0 (this device) | K083517 | Intellivue Patient Monitor, Models MP2, MP5, MP20, MP30, MP40, MP50, MO60… | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2009 | — |
| +1 | K091927 | Intellivue Patient Monitors ,Models MP40, MP50, MP60, MP70, MP80, MP90 | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2009 | — |
| +1 | K100939 | Intellivue Patient Monitor Model: MP2, MP5, MP5T, MP20, MP30, MP40, MP50… | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2010 | — |
| +1 | K102562 | Intellivue Patient Monitor, Models MP2, X2, MP5, MP5T, MP20, MP30, MP40, MP50… | Philips Medizin Systeme Boblingen GmbH | 2010 | — |
| +2 | K101449 | Intellivue Patient Monitor | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2010 | — |
| +1 | K110622 | Intellivue Patient Monitor | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2011 | 2 |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1985 | 1 | 0 |
| 1987 | 1 | 0 |
| 1989 | 2 | 0 |
| 1990 | 6 | 0 |
| 1991 | 6 | 0 |
| 1992 | 6 | 0 |
| 1993 | 5 | 0 |
| 1994 | 2 | 0 |
| 1995 | 6 | 0 |
| 1996 | 10 | 0 |
| 1997 | 7 | 0 |
| 1998 | 13 | 0 |
| 1999 | 10 | 0 |
| 2000 | 19 | 0 |
| 2001 | 7 | 0 |
| 2002 | 13 | 0 |
| 2003 | 12 | 0 |
| 2004 | 12 | 0 |
| 2005 | 2 | 0 |
| 2006 | 4 | 0 |
| 2007 | 1 | 0 |
| 2008 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2009 | 1 | 0 |
| 2010 | 4 | 0 |
| 2011 | 3 | 0 |
| 2012 | 7 | 0 |
| 2013 | 6 | 0 |
| 2014 | 7 | 0 |
| 2015 | 4 | 0 |
| 2016 | 8 | 0 |
| 2017 | 9 | 0 |
| 2018 | 8 | 0 |
| 2019 | 6 | 0 |
| 2020 | 6 | 0 |
| 2021 | 5 | 0 |
| 2022 | 11 | 0 |
| 2023 | 10 | 0 |
| 2024 | 9 | 0 |
| 2025 | 14 | 0 |
| 2026 | 7 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DSI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DSI device
- #1 K243349 BodyGuardian Remote Monitoring System (BGRMS…score 13.1 · 9 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (23)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K021778 | Philips Component Compact Monitor, Release a.04, Model #M1275BSummary page 2…ephalogram Signal 3. The modified devices are substantially equivalent to previously cleared Philips IntelliVue Patient Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(05352… | 2002 |
| * | K030038 | Philips MP60, MP70 and MP90 Intellivue Patient Monitors with Portal Technology and M3185…Summary page 2…Signal 3. The modified devices are substantially equivalent to previously cleared Philips IntelliVue Patient Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221… | 2003 |
| * | K032858 | The Philips Intellivue MP40, MP50, MP60, MP70,and MP90 Patient Monitors, Release B.O.Summary page 2…3. The modified devices are substantially equivalent to previously cleared Philips IntelliVue Patient Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541,… | 2003 |
| * | K033444 | Philips Medical Systems, M3012A- Hemodynamic Extension to the Multi-Measurement ServerSummary page 2…modified devices are substantially equivalent to previously cleared Philips IntelliVue Patient Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052,… | 2003 |
| * | K033513 | Easi Ecg AlgorithmSummary page 2…s are substantially equivalent to previously cleared Philips IntelliVue Patient Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062… | 2004 |
| * | K040304 | Philips Intellivue Patient Monitor, Models MP40 & MP50Summary page 2…tantially equivalent to previously cleared Philips IntelliVue Patient Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283,… | 2004 |
| * | K040357 | M3290A Intellivue Information Center Software Release F.O and the M4840A Telemetry…Summary page 2…equivalent to previously cleared Philips IntelliVue Patient Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315,… | 2004 |
| * | K041235 | Philips MP20, MP30, MP40, MP50. MP60, MP70 and MP90 Intellivue Patient MonitorsSummary page 2…to previously cleared Philips IntelliVue Patient Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392,… | 2004 |
| * | K042845 | The Philips MP20, MP30, MP40, MP50, MP60, MP70, and MP90 Intellivue Patient MonitorsSummary page 2…previously cleared Philips IntelliVue Patient Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725… | 2004 |
| * | K050762 | Philips Intellivue Patient Monitor, Models MP20, MP30, MP40, MP50, MP60, MP70 and MP90Summary page 2…y cleared Philips IntelliVue Patient Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426… | 2005 |
| * | K051106 | The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient MonitorsSummary page 2…Philips IntelliVue Patient Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633… | 2005 |
| * | K052801 | Intellivue Patient Monitors with Release C.02, Models MP20, MP30, MP40, MP50, MP60…Summary page 2…ue Patient Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633.… | 2005 |
| * | K053522 | Philips MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient Monitors, Release D.00Summary page 2…Monitors marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633.… | 2006 |
| * | K060221 | The Phillips, Model MP20,MP30,MP40,MP50,MP60,MP70,MP80,and MP90 Intellivue Patient…Summary page 2…s marketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633.… | 2006 |
| * | K060541 | The Philips MP20,MP30,MP40,MP50,MP60,MP70,MP80 and MP90 Intellivue Atient MonitorsSummary page 2…arketed pursuant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633.… | 2006 |
| * | K061052 | The Philips Intellivue Patient Monitors, Models MP20,MP30,MP40,MP50,MP60,MP70,MP80,MP90Summary page 2…suant to 1(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633.… | 2006 |
| * | K061610 | Philips Model MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient…Summary page 2…(021778, 1(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633.… | 2006 |
| * | K062283 | The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90 Intellivue Patient MonitorsSummary page 2…(030038, 1(032858, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633. to 4… | 2006 |
| * | K063315 | Intellivue Patient Monitors, Models MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90Summary page 2…8, 1(033444, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633. to 4. The modificati… | 2006 |
| * | K062392 | Philips MP5 Intellivue Patient MonitorSummary page 2…4, 1(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633. to 4. The modification is a ch… | 2006 |
| * | K063725 | MP5 Intellivue Patient MonitorSummary page 2…(033513, 1(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633. to 4. The modification is a change of th… | 2007 |
| * | K071426 | MP2, X2, MP5, MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90 Intellivue Patient…Summary page 2…(040304, 1(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633. to 4. The modification is a change of the labellin… | 2007 |
| * | K082633 | Intellivue Patient Monitor, Intellivue XDS, Models MP2, MP5, MP20, MP30, MP40, MP50…Summary page 2…(040357, 1(041235, K042845, 1(050762, 1(051106, 1(052801, K(053522, K060221, K060541, K(061052, 1(061610, 1(062283, 1(063315, 1(062392, 1(063725, 1(071426, 1(082633. to 4. The modification is a change of the labelling with reg… | 2008 |
What descends from it? (125)
See all 12518 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K091927 | Intellivue Patient Monitors ,Models MP40, MP50, MP60, MP70, MP80, MP90 | 2009 | 124 |
| K100939 | Intellivue Patient Monitor Model: MP2, MP5, MP5T, MP20, MP30, MP40, MP50, MP60, MP70… | 2010 | 123 |
| K102562 | Intellivue Patient Monitor, Models MP2, X2, MP5, MP5T, MP20, MP30, MP40, MP50, MP60… | 2010 | 103 |
| K110622 | Intellivue Patient Monitor | 2011 | 90 |
| K110474 | Philips Intellivue TCG10 | 2011 | 84 |
| K113657 | Intellivue Patient Monitor | 2012 | 81 |
| K113441 | Physiological Monitor, Patient Monitor | 2012 | 78 |
| K120366 | Intellivue Patient Monitor | 2012 | 46 |
| K122439 | Intellivue Patient Monitor | 2012 | 41 |
| K131872 | Intellivue Patient Monitor MX500, Intellivue Patient Monitor MX550 | 2013 | 37 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Nov 18, 2020 | Class II | Z-0545-2021 | Process control | Speakers on IntelliVue X2 and IntelliVue MP2 may fail, identified by the display of a Speaker Malfunct. INOP or by the absence of audible sound, may result in delayed treatment of the patient. |
| Aug 31, 2010 | Not classified | Z-2626-2010 | Process design | Speakers on the Philips IntelliVue X2 and MP2 patient monitors may fail, causing absence of an audible alarm and delaying patient treatment. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 15 years and passes through 8 companies; a new generation was cleared every 3 months on median.
- 21 of the 172 ancestors have a recall of any class.
- Of its descendants, K091927 (Philips Medizinsysteme Boeblingen GmbH, Cardiac AN, 2009) has gone furthest, with 124 descendants of its own.
- 30 other devices also cite its predicate K021778.
How does its category compare?
All DSI devicesDSI Detector And Alarm, Arrhythmia: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · DSI
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DSI
243in 2019
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DSI
18in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DSI
712in 2025
MAUDE reports naming product code DSI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 7 | 151 | 4 | 64 |
| 2008 | 5 | 70 | 8 | 156 |
| 2009 | 6 | 73 | 3 | 279 |
| 2010 | 6 | 111 | 5 | 823 |
| 2011 | 6 | 114 | 3 | 793 |
| 2012 | 3 | 113 | 1 | 766 |
| 2013 | 1 | — | 0 | 795 |
| 2014 | 4 | 200 | 0 | 1,000 |
| 2015 | 9 | 127 | 0 | 1,645 |
| 2016 | 6 | 224 | 0 | 4,352 |
| 2017 | 0 | — | 0 | 3,594 |
| 2018 | 2 | — | 1 | 3,648 |
| 2019 | 3 | 243 | 4 | 3,485 |
| 2020 | 2 | — | 2 | 3,084 |
| 2021 | 0 | — | 0 | 3,092 |
| 2022 | 0 | — | 1 | 1,638 |
| 2023 | 2 | — | 2 | 1,616 |
| 2024 | 1 | — | 0 | 1,320 |
| 2025 | 1 | — | 18 | 712 |
| 2026 | 1 | — | 1 | — |
What is it indicated for?
Indicated for use by health care professionals whenever there is a need for monitoring the physiological parameters of patients Intended for monitoring and recording of and to generate alarms for multiple physiological parameters of adults, pediatrics and neonates in hospital environments
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K083517 · printed Nov 4, 2026
Cite this page
510(k) Report. “K083517: Intellivue Patient Monitor, Models MP2, MP5, MP20, MP30, MP40, MP50, MO60, MP7-, MP80, and MP90.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K083517
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026