510(k) · Cleared
Recalled · Class II · 2017GE Lightspeed Act FP16
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Ge Medical Systems, Inc. · JAK System, X-Ray, Tomography, Computed
Cleared on Jun 24, 2009 as substantially equivalent to K012385 (Ge Medical Systems, Inc., 2001) after a 15-day review. Its family tree reaches back 1 generation to 2001. It has been recalled once.
- Decided
- Jun 24, 2009
- Review
- 15 days
- Class
- Class II
- Product code
- JAK
- Recalls
- 1
- Predicates
- 1
Its longest line of descent runs back 1 generation to K012385 (2001). No later device cites it as a predicate yet.
- Root · 1 generation backK012385 Hispeed X/I Smart Gantry OptionGe Medical Systems, Inc. · 2001
- This deviceK091673 GE Lightspeed Act FP16Ge Medical Systems, Inc. · 2009
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K012385 | Hispeed X/I Smart Gantry Option | Ge Medical Systems, Inc. | 2001 | — |
| 0 (this device) | K091673 | GE Lightspeed Act FP16 | Ge Medical Systems, Inc. | 2009 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JAK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JAK device
- #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K012385 | Hispeed X/I Smart Gantry OptionSummary page 1…Comparison with Predicate Device: GE LightSpeed ACT FP16 is substantially equivalent in terms of safety and effectiveness to the GE HiSpeed X/i Smart Gantry Option (K012385). Both systems utilize a movable CT gantry to scan the patient while placed on a stationary table. They have the same tec… | 2001 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| May 19, 2017 | Class II | Z-2187-2017 | Software design | It was discovered that an issue has been identified that can result in a scan starting before the prescribed delay has completed. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has no recall.
How does its category compare?
All JAK devicesJAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.
FDA decisions per year · JAK
27in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JAK
141in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JAK
17in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JAK
219in 2025
MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 14 | 27 | 11 | 76 |
| 2008 | 26 | 42 | 16 | 120 |
| 2009 | 15 | 31 | 29 | 105 |
| 2010 | 7 | 92 | 51 | 119 |
| 2011 | 16 | 155 | 34 | 205 |
| 2012 | 28 | 121 | 23 | 192 |
| 2013 | 17 | 132 | 11 | 414 |
| 2014 | 30 | 200 | 10 | 308 |
| 2015 | 30 | 140 | 28 | 454 |
| 2016 | 25 | 129 | 44 | 365 |
| 2017 | 29 | 96 | 33 | 338 |
| 2018 | 24 | 114 | 10 | 543 |
| 2019 | 28 | 94 | 5 | 233 |
| 2020 | 30 | 112 | 8 | 177 |
| 2021 | 20 | 145 | 15 | 261 |
| 2022 | 30 | 131 | 9 | 199 |
| 2023 | 27 | 139 | 9 | 310 |
| 2024 | 26 | 141 | 20 | 212 |
| 2025 | 27 | 141 | 17 | 219 |
| 2026 | 21 | 167 | 23 | — |
What is it indicated for?
The GE LightSpeed TM ACT FP16 is indicated for head and whole body X-ray computed tomography applications.
GE LightSpeed TM ACT FP16 is indicated for use in generating fluoroscopic images of human anatomy for vascular angiography, cardiology, diagnostic and interventional procedures, and optionally, rotational imaging procedures. It is intended to replace fluoroscopic images obtained through image intensifier technology and is not intended for mammography applications.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K091673 · printed Nov 6, 2026
Cite this page
510(k) Report. “K091673: GE Lightspeed Act FP16.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K091673
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026