510(k) Report

510(k) · Cleared

Cleared

Interface Acetabular Cup Liners

K092443510(k) SpecialCleared Oct 23, 200974-day reviewClass II21 CFR 888.3358

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Omni Life Science, Inc. · LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented

Cleared on Oct 23, 2009 as substantially equivalent to K031110 (Apex Surgical, LLC, 2003) and 5 other predicates after a 74-day review. Its family tree reaches back 6 generations to 1993. 1 later device descends from it.

Decided
Oct 23, 2009
Review
74 days
Class
Class II
Product code
LPH
Recalls
None
Predicates
6

Its longest line of descent runs back 6 generations to K930712 (1993). 21 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2007: 1 other ancestor1999: 1 other ancestor1995: 3 other ancestors1994: 2 other ancestors2006: 1 other ancestor2004: 1 other ancestor2001: 1 other ancestor2000: 2 other ancestors2005: 1 other ancestor1997: 1 other ancestor1996: 1 other ancestor2017: 1 descendant clearedK930712 · P.F.C. Total Hip System Porous Coated Modular · Johnson & Johnson Orthopaedics, Inc. · 1993K983014 · Summit Acetabular System · Johnson & Johnson Professionals, Inc. · 1998×2: 2 generations cleared close together, K000306 (2000), K001534 (2000) K031110 · Apex Modular Acetabular Cup · Apex Surgical, LLC · 2003K073150 · Apex-LNK Poly Acetabular Cup Liners · Omni Life Science, Inc. · 20081990200020102020
  1. Root · 6 generations backK930712 P.F.C. Total Hip System Porous Coated ModularJohnson & Johnson Orthopaedics, Inc. · 1993
  2. 5 generations backK983014 Summit Acetabular SystemJohnson & Johnson Professionals, Inc. · 1998
  3. 4 generations backK000306 Pinnacle Acetabular SystemDePuy Orthopaedics, Inc. · 2000 · Recalled
  4. 3 generations backK001534 Pinnacle Acetabular SystemDePuy Orthopaedics, Inc. · 2000
  5. 2 generations backK031110 Apex Modular Acetabular CupApex Surgical, LLC · 2003
  6. 1 generation backK073150 Apex-LNK Poly Acetabular Cup LinersOmni Life Science, Inc. · 2008
  7. This deviceK092443 Interface Acetabular Cup LinersOmni Life Science, Inc. · 2009
  8. Descendant · cites it directly · 0 of its ownK171156 OMNI Anseris Hip StemOmnilife Science · 2017

Most influential descendants

Showing 1 of 1 · See all
  • K171156OMNI Anseris Hip StemOmnilife Science · 2017 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K930712P.F.C. Total Hip System Porous Coated ModularJohnson & Johnson Orthopaedics, Inc.1993—
−5K983014Summit Acetabular SystemJohnson & Johnson Professionals, Inc.1998—
−4K000306Pinnacle Acetabular SystemDePuy Orthopaedics, Inc.20001
−3K001534Pinnacle Acetabular SystemDePuy Orthopaedics, Inc.2000—
−2K031110Apex Modular Acetabular CupApex Surgical, LLC2003—
−1K073150Apex-LNK Poly Acetabular Cup LinersOmni Life Science, Inc.2008—
0 (this device)K092443Interface Acetabular Cup LinersOmni Life Science, Inc.2009—
+1K171156OMNI Anseris Hip StemOmnilife Science2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199420
199530
199610
199710
199910
200020
200110
200410
200510
200610
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
FIG. 1 — Lineage of K092443, 1993–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LPH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LPH device

  1. #1 K233498 Stryker Orthopaedics Hip Systems Labeling Updatescore 24.2 · 20 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (6)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K031110Apex Modular Acetabular Cup
Summary page 2
…f 2 510(K) SummARY 5. Predicate Device Comparison Substantial equivalence is claimed to the InterfaceTM (K03 1110), the ApeX-LNK PolyTM (K062489 and K073150), and the Zimmer Trilogy® Acetabular System (K934765, K953490, and K972774) UHMWPE cup…
Apex Surgical, LLC2003—
*K062489Apex Hcla Acetabular Cup Liners
Summary page 2
…510(K) SummARY 5. Predicate Device Comparison Substantial equivalence is claimed to the InterfaceTM (K03 1110), the ApeX-LNK PolyTM (K062489 and K073150), and the Zimmer Trilogy® Acetabular System (K934765, K953490, and K972774) UHMWPE cup liners. The following table su…
Omnilife Science2007—
*K073150Apex-LNK Poly Acetabular Cup Liners
Summary page 2
…510(K) SummARY 5. Predicate Device Comparison Substantial equivalence is claimed to the InterfaceTM (K03 1110), the ApeX-LNK PolyTM (K062489 and K073150), and the Zimmer Trilogy® Acetabular System (K934765, K953490, and K972774) UHMWPE cup liners. The following table summarizes the…
Omni Life Science, Inc.2008—
*K934765Trilogy Acetabular System
Summary page 2
…evice Comparison Substantial equivalence is claimed to the InterfaceTM (K03 1110), the ApeX-LNK PolyTM (K062489 and K073150), and the Zimmer Trilogy® Acetabular System (K934765, K953490, and K972774) UHMWPE cup liners. The following table summarizes the similarities and differences between the subject Ape…
Zimmer, Inc.199416
*K953490Trilogy Acetabular Shell & Liners 36MM
Summary page 2
…parison Substantial equivalence is claimed to the InterfaceTM (K03 1110), the ApeX-LNK PolyTM (K062489 and K073150), and the Zimmer Trilogy® Acetabular System (K934765, K953490, and K972774) UHMWPE cup liners. The following table summarizes the similarities and differences between the subject Apex Modular…
Zimmer, Inc.19952
*K972774Gas Plasma Sterilization
Summary page 2
…tantial equivalence is claimed to the InterfaceTM (K03 1110), the ApeX-LNK PolyTM (K062489 and K073150), and the Zimmer Trilogy® Acetabular System (K934765, K953490, and K972774) UHMWPE cup liners. The following table summarizes the similarities and differences between the subject Apex Modular InterfaceTM…
Zimmer, Inc.1999—

Also cleared against K031110: 7 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K171156OMNI Anseris Hip StemOmnilife Science20170

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 5 companies; a new generation was cleared every 2.9 years on median.
  • 3 of the 21 ancestors have a recall of any class.
  • Of its descendants, K171156 (Omnilife Science, 2017) has gone furthest, with 0 descendants of its own.
  • 7 other devices also cite its predicate K031110.

How does its category compare?

All LPH devices

LPH Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2009, this device’s year, is highlighted.

FDA decisions per year · LPH

12in 2025

2007: 102008: 102009: 32010: 152011: 162012: 252013: 112014: 202015: 182016: 102017: 122018: 92019: 222020: 72021: 82022: 142023: 102024: 62025: 122026 (partial year): 8
2007high 25 (2012) · low 3 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LPH

153in 2025

2007: 116 days median2008: 86 days median2009: 112 days median2010: 100 days median2011: 110 days median2012: 76 days median2013: 135 days median2014: 129 days median2015: 111 days median2016: 150 days median2017: 121 days median2018: 145 days median2019: 164 days median2020: 164 days median2021: 410 days median2022: 247 days median2023: 111 days median2024: 92 days median2025: 153 days median2026 (partial year): 256 days median
2007high 410 (2021) · low 76 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LPH

4in 2025

2007: 162008: 12009: 22010: 222011: 262012: 302013: 92014: 32015: 12016: 82017: 142018: 22019: 82020: 62021: 42022: 22023: 22024: 12025: 42026 (partial year): 2
2007high 30 (2012) · low 1 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LPH

6,163in 2025

2007: 5092008: 7062009: 1,1562010: 2,0072011: 3,3202012: 3,7852013: 5,0022014: 5,1632015: 5,8302016: 4,9002017: 5,3122018: 5,9542019: 7,1302020: 5,4292021: 5,9782022: 5,2232023: 5,3452024: 5,6262025: 6,163
2007high 7,130 (2019) · low 509 (2007)2025

MAUDE reports naming product code LPH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071011616509
200810861706
2009311221,156
201015100222,007
201116110263,320
20122576303,785
20131113595,002
20142012935,163
20151811115,830
20161015084,900
201712121145,312
2018914525,954
20192216487,130
2020716465,429
2021841045,978
20221424725,223
20231011125,345
202469215,626
20251215346,163
202682562—

What is it indicated for?

The InterfaceTM Acetabular Cup Liners are intended for use with the InterfaceTM Acetabular Cup, in combination with the Apex ModularTM, Apex K2TM, or Apex K1TM Hip Stem in total hip replacement procedures. This acetabular cup is intended to articulate with a metal (cobalt chromium) or ceramic (alumina) femoral head. This prosthesis is intended for single use implantation, and may be used for the following conditions, as appropriate: * Non-inflammatory…

Read the full statement (108 words)

The InterfaceTM Acetabular Cup Liners are intended for use with the InterfaceTM Acetabular Cup, in combination with the Apex ModularTM, Apex K2TM, or Apex K1TM Hip Stem in total hip replacement procedures. This acetabular cup is intended to articulate with a metal (cobalt chromium) or ceramic (alumina) femoral head. This prosthesis is intended for single use implantation, and may be used for the following conditions, as appropriate:

* Non-inflammatory degenerative joint disease, including osteoarthritis and avascular necrosis;

* Rheumatoid arthritis;

* Correction of functional deformity;

* Congenital dislocation;

* Revision procedures where other treatments or devices have failed;

* Femoral neck and trochanteric fractures of the proximal femur.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K092443: Interface Acetabular Cup Liners.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K092443

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026