K093120510(k) SpecialCleared Feb 17, 2010138-day reviewClass II21 CFR 876.5860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Baxter Healthcare Corporation - Renal Division · KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System

Cleared on Feb 17, 2010 as substantially equivalent to K083778 (Baxter Healthcare Corporation, 2009) after a 138-day review. Its family tree reaches back 8 generations to 2001. 6 later devices descend from it.

Decided
Feb 17, 2010
Review
138 days
Class
Class II
Product code
KDI
Recalls
None
Predicates
1

Its longest line of descent runs back 8 generations to K001283 (2001). 16 ancestors in all, the oldest K872364 (1987). 6 later devices descend from it, 1 citing it directly.

  1. Root · 8 generations backK001283 Lifemate Hemofiltration SystemNxstage Medical, Inc. · 2001
  2. 7 generations backK012510 Modification to: Lifemate Hemofiltration SystemNxstage Medical, Inc. · 2001
  3. 6 generations backK020858 Nxstage Therapy SystemNxstage Medical, Inc. · 2002
  4. 5 generations backK030470 Nxstage System OneNxstage Medical, Inc. · 2003
  5. 4 generations backK041424 Nxstage System OneNxstage Medical, Inc. · 2004
  6. 3 generations backK050525 Nxstage System OneNxstage Medical, Inc. · 2005 · Recalled
  7. 2 generations backK062079 Xenium Dialyzer, Models 110, 130, 150, 170, 190 and 210Baxter Healthcare Corporation · 2006
  8. 1 generation backK083778 Xenium XPH, Models 110, 130, 150, 170, 190 and 210Baxter Healthcare Corporation · 2009
  9. This deviceK093120 Xenium XPM 110, Xenium XPM 130, Models M25649A, M25650A, Xenium XPM…Baxter Healthcare Corporation - Renal Division · 2010
  10. Descendant · cites it directly · 5 of its ownK122347 Elisio-H and Elisio-M HemodialyzersNipro Medical Corporation · 2013
  11. Descendant · 2 generations on · 3 of its ownK131935 Elisio-H Hemodialyzer, Elisio-M HemodialyzerNipro Medical Corporation · 2013
  12. Descendant · 2 generations on · 2 of its ownK131381 Elisio-H HemodialyzerNipro Medical Corporation · 2013
  13. Descendant · 3 generations on · 1 of its ownK140191 Elisio-H HemodialyzerNipro Medical Corporation · 2014
  14. Descendant · 3 generations on · 0 of its ownK260533 Elisio™-HNipro Medical Corporation · 2026

Showing 5 of 6 descendants. See all descendants

Descendants cleared per year

2013: 32014: 12017: 12026: 1
2013high 3 (2013) · low 0 (2015)2026

Most influential descendants

Showing 5 of 6 · See all
  • K122347Elisio-H and Elisio-M HemodialyzersNipro Medical Corporation · 2013 · cites it directly5descendants
  • K131935Elisio-H Hemodialyzer, Elisio-M HemodialyzerNipro Medical Corporation · 2013 · 2 generations on3descendants
  • K131381Elisio-H HemodialyzerNipro Medical Corporation · 2013 · 2 generations on2descendants
  • K140191Elisio-H HemodialyzerNipro Medical Corporation · 2014 · 3 generations on1descendant
  • K260533Elisio™-HNipro Medical Corporation · 2026 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K001283Lifemate Hemofiltration SystemNxstage Medical, Inc.2001—
−7K012510Modification to: Lifemate Hemofiltration SystemNxstage Medical, Inc.2001—
−6K020858Nxstage Therapy SystemNxstage Medical, Inc.2002—
−5K030470Nxstage System OneNxstage Medical, Inc.2003—
−4K041424Nxstage System OneNxstage Medical, Inc.2004—
−3K050525Nxstage System OneNxstage Medical, Inc.20052
−2K062079Xenium Dialyzer, Models 110, 130, 150, 170, 190 and 210Baxter Healthcare Corporation2006—
−1K083778Xenium XPH, Models 110, 130, 150, 170, 190 and 210Baxter Healthcare Corporation2009—
0 (this device)K093120Xenium XPM 110, Xenium XPM 130, Models M25649A, M25650A, Xenium XPM 150…Baxter Healthcare Corporation - Renal Division2010—
+1K122347Elisio-H and Elisio-M HemodialyzersNipro Medical Corporation2013—
+2K131935Elisio-H Hemodialyzer, Elisio-M HemodialyzerNipro Medical Corporation2013—
+2K131381Elisio-H HemodialyzerNipro Medical Corporation2013—
+3K140191Elisio-H HemodialyzerNipro Medical Corporation2014—
+3K260533Elisio™-HNipro Medical Corporation2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198910
199110
199410
199710
199820
200310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201330
201410
201710
202610
FIG. 1 — Lineage of K093120, 2001–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDI device

  1. #1 K243874 FX CorAL 60 (F00012969); FX CorAL 80…score 18.2 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K083778Xenium XPH, Models 110, 130, 150, 170, 190 and 210
Summary page 2
…____ ~~Device Cmay Previous&51O(k)- - Clearance-date.~- Xeniumn XPH Baxter K083778 Februrary 20, Healthcare 2009…
Baxter Healthcare Corporation2009—

Also cleared against K083778: 2 other devices →

What descends from it? (6)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K122347Elisio-H and Elisio-M HemodialyzersNipro Medical Corporation20135

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 3 companies; a new generation was cleared every 12 months on median.
  • 2 of the 16 ancestors have a recall of any class.
  • Of its descendants, K122347 (Nipro Medical Corporation, 2013) has gone furthest, with 5 descendants of its own.
  • 2 other devices also cite its predicate K083778.

How does its category compare?

All KDI devices

KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · KDI

9in 2025

2007: 112008: 62009: 42010: 92011: 52012: 62013: 112014: 82015: 52016: 52017: 82018: 22019: 42020: 92021: 22022: 72023: 72024: 72025: 92026 (partial year): 6
2007high 11 (2007) · low 2 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDI

199in 2025

2007: 91 days median2008: 148 days median2009: 236 days median2010: 186 days median2011: 85 days median2012: 153 days median2013: 247 days median2014: 164 days median2015: 69 days median2016: 230 days median2017: 188 days median2019: 263 days median2020: 266 days median2022: 259 days median2023: 157 days median2024: 235 days median2025: 199 days median2026 (partial year): 154 days median
2007high 266 (2020) · low 69 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KDI

2in 2025

2007: 42009: 32010: 12011: 42012: 12013: 22014: 32015: 52016: 42017: 12018: 12019: 62021: 22022: 172023: 8, 8 Class I2024: 4, 2 Class I2025: 22026 (partial year): 2
2007high 17 (2022) · low 0 (2008)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · KDI

2,786in 2025

2007: 9162008: 1,0422009: 5222010: 8232011: 2,2702012: 1,7652013: 2,3602014: 6,1542015: 4,1822016: 7662017: 9632018: 1,7162019: 1,5872020: 1,6332021: 1,9442022: 2,1802023: 2,6922024: 2,4412025: 2,786
2007high 6,154 (2014) · low 522 (2009)2025

MAUDE reports naming product code KDI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711914916
2008614801,042
200942363522
201091861823
201158542,270
2012615311,765
20131124722,360
2014816436,154
201556954,182
201652304766
201781881963
20182—11,716
2019426361,587
2020926601,633
20212—21,944
20227259172,180
202371578 (8)2,692
202472354 (2)2,441
2025919922,786
202661542—

What is it indicated for?

Hemodialysis with Xenium XPM dialyzers is indicated for patients with acute or chronic renal failure when conservative therapy is judged to be inadequate. It also may be indicated in the treatment of patients intoxicated with poisons or drugs.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K093120: Xenium XPM 110, Xenium XPM 130, Models M25649A, M25650A, Xenium XPM 150, Xenium XPM 170.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K093120

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026