510(k) · Cleared
ClearedAesculap Sterilcontainer S
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Aesculap · FRG Wrap, Sterilization
Cleared on May 11, 2010 as substantially equivalent to K040865 (Aesculap, 2004) after a 167-day review. Its family tree reaches back 1 generation to 2004. 4 later devices descend from it.
- Decided
- May 11, 2010
- Review
- 167 days
- Class
- Class II
- Product code
- FRG
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K040865 (2004). 4 later devices descend from it, 2 citing it directly.
- Root · 1 generation backK040865 Aesculap Sterrad 100S Compatable SterilcontainerAesculap · 2004
- This deviceK093649 Aesculap Sterilcontainer SAesculap · 2010
- Descendant · cites it directly · 2 of its ownK151242 SterilContainer SAesculap, Inc. · 2015
- Descendant · 2 generations on · 1 of its ownK162815 SterilContainer S SystemAesculap, Inc. · 2017
- Descendant · 3 generations on · 0 of its ownK193582 SterilContainer S2 SystemAesculap, Inc. · 2020
- Descendant · cites it directly · 0 of its ownK143729 SterilContainer SAesculap, Inc. · 2015
Most influential descendants
Showing 4 of 4 · See all- K151242SterilContainer SAesculap, Inc. · 2015 · cites it directly2descendants
- K162815SterilContainer S SystemAesculap, Inc. · 2017 · 2 generations on1descendant
- K193582SterilContainer S2 SystemAesculap, Inc. · 2020 · 3 generations on0descendants
- K143729SterilContainer SAesculap, Inc. · 2015 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K040865 | Aesculap Sterrad 100S Compatable Sterilcontainer | Aesculap | 2004 | — |
| 0 (this device) | K093649 | Aesculap Sterilcontainer S | Aesculap | 2010 | — |
| +1 | K151242 | SterilContainer S | Aesculap, Inc. | 2015 | — |
| +2 | K162815 | SterilContainer S System | Aesculap, Inc. | 2017 | — |
| +3 | K193582 | SterilContainer S2 System | Aesculap, Inc. | 2020 | — |
| +1 | K143729 | SterilContainer S | Aesculap, Inc. | 2015 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2015 | 2 | 0 |
| 2017 | 1 | 0 |
| 2020 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FRG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FRG device
- #1 K234050 HALYARD® ONE-STEP® Sterilization Wrap…score 15.8 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K040865 | Aesculap Sterrad 100S Compatable SterilcontainerSummary page 1…ALENCE Aesculap®, Inc. believes that the SterilContainer S is substantially equivalent to: Aesculap STERRAD10OS Compatiaible Sterilcontainer (K040865). DEVICE DESCRIPTION The Aesculap Sterilcontainer S is designed as a container system that will allow for… | 2004 |
What descends from it? (4)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All FRG devicesFRG Wrap, Sterilization: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.
FDA decisions per year · FRG
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FRG
151in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FRG
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FRG
18in 2025
MAUDE reports naming product code FRG, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 182 | 0 | 1 |
| 2008 | 2 | — | 0 | 2 |
| 2009 | 4 | 171 | 0 | 2 |
| 2010 | 4 | 213 | 0 | 0 |
| 2011 | 6 | 110 | 0 | 12 |
| 2012 | 10 | 133 | 0 | 4 |
| 2013 | 6 | 146 | 2 | 5 |
| 2014 | 8 | 177 | 0 | 13 |
| 2015 | 12 | 196 | 0 | 9 |
| 2016 | 9 | 131 | 0 | 20 |
| 2017 | 9 | 260 | 29 | 7 |
| 2018 | 5 | 150 | 0 | 22 |
| 2019 | 9 | 258 | 0 | 10 |
| 2020 | 5 | 122 | 14 | 21 |
| 2021 | 4 | 170 | 0 | 9 |
| 2022 | 9 | 217 | 2 | 4 |
| 2023 | 9 | 230 | 0 | 13 |
| 2024 | 11 | 182 | 0 | 21 |
| 2025 | 9 | 151 | 0 | 18 |
| 2026 | 4 | 247 | 0 | — |
What is it indicated for?
The Aesculap Sterilcontainer S is a reusable sterilization container system intended to be used to enclose another medical device that is to be sterilized by a healthcare provider. It is intended to allow sterilization of the enclosed device and also maintain sterility of the enclosed device until used. This container system is compatible for use with the V-PRO 1 and V-PRO Plus Systems. The Sterilcontainer S is recommended for surface and lumens: * 1mm…
Read the full statement (133 words)
The Aesculap Sterilcontainer S is a reusable sterilization container system intended to be used to enclose another medical device that is to be sterilized by a healthcare provider. It is intended to allow sterilization of the enclosed device and also maintain sterility of the enclosed device until used. This container system is compatible for use with the V-PRO 1 and V-PRO Plus Systems.
The Sterilcontainer S is recommended for surface and lumens:
* 1mm internal diameter and < 125 mm in length
* 2mm internal diameter and < 250 mm in length
* 3mm internal diameter and < 400 mm in length
Lumen Cycle - The maximum number of lumens per load is 20 lumens.
The attached table identifies which Sterilcontainer S may be sterilized in the V-PRO 1 and V-PRO Plus Systems.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K093649 · printed Nov 6, 2026
Cite this page
510(k) Report. “K093649: Aesculap Sterilcontainer S.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K093649
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026