Holter in-Line Shunt Filter, Holter Cerebral Catheter Reservoir, Accu-Flo Connectors; Accu-Flo Three Way Connector; Codm

K102961510(k) SpecialCleared Feb 18, 2011136-day reviewClass II21 CFR 882.5550

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Codman & Shurtleff, Inc. · JXG Shunt, Central Nervous System And Components

Cleared on Feb 18, 2011 as substantially equivalent to K944222 (Johnson & Johnson Professionals, Inc., 1995) and 1 other predicate after a 136-day review. Its family tree reaches back 2 generations to 1995.

Decided
Feb 18, 2011
Review
136 days
Class
Class II
Product code
JXG
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K944222 (1995). No later device cites it as a predicate yet.

  1. Root · 2 generations backK944222 Codman-Medos Valve Shunt SystemJohnson & Johnson Professionals, Inc. · 1995
  2. 1 generation backK973774 Codman Hakim Micro Precision ValveJohnson & Johnson Professionals, Inc. · 1997
  3. This deviceK102961 Holter in-Line Shunt Filter, Holter Cerebral Catheter Reservoir…Codman & Shurtleff, Inc. · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K944222Codman-Medos Valve Shunt SystemJohnson & Johnson Professionals, Inc.1995—
−1K973774Codman Hakim Micro Precision ValveJohnson & Johnson Professionals, Inc.1997—
0 (this device)K102961Holter in-Line Shunt Filter, Holter Cerebral Catheter Reservoir, Accu-Flo…Codman & Shurtleff, Inc.2011—
FIG. 1 — Lineage of K102961, 1995–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JXG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JXG device

  1. #1 K243531 Codman Libertís Shunt Catheter with Bactiseal…score 11.9 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (12)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K944222Codman-Medos Valve Shunt System
Summary page 2
…Reservoir, LeRoy Design Preamendment - CODMAN® ACCU-FLO® Straight Connectors K944222 - CODMAN® MEDOS® Straight Connector Preamendment - CODMAN® HOLTER® Type A Fixation and…
Johnson & Johnson Professionals, Inc.1995—
*K973774Codman Hakim Micro Precision Valve
Summary page 2
…K944222 - CODMAN® MEDOS® Right Angle Connector Preamendment - CODMAN® HOLTER® SELKER Reservoir K973774 - CODMAN® ACCU-FLO® Straight Connector, Plastic…
Johnson & Johnson Professionals, Inc.1997—
*—CODMAN® HOLTER® In-Line Shunt Filter, Hoffman Design
Named without a submission number
—
*—CODMAN® HOLTER® Cerebral Catheter-Reservoir, LeRoy Design
Named without a submission number
—
*—CODMAN® ACCU-FLO® Straight Connectors
Named without a submission number
—
*—CODMAN® HOLTER® Type A Fixation and Joining Connector
Named without a submission number
—
*—CODMAN® HOLTER® Type B Fixation and Joining Connector
Named without a submission number
—
*—CODMAN® ACCU-FLO® Connector, Three Way
Named without a submission number
—
*—CODMAN® HOLTER® RICKHAM® Reservoir
Named without a submission number
—
*—CODMAN® HOLTER® SALMON-RICKHAM® Reservoir
Named without a submission number
—
*—CODMAN® ACCU-FLO® Right Angle Connectors
Named without a submission number
—
*—CODMAN® HOLTER® SELKER Reservoir
Named without a submission number
—

Also cleared against K944222: 7 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 2 companies; a new generation was cleared every 13.1 years on median.
  • None of the 2 ancestors has a recall.
  • 7 other devices also cite its predicate K944222.

How does its category compare?

All JXG devices

JXG Shunt, Central Nervous System And Components: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · JXG

8in 2025

2007: 32008: 62009: 52010: 32011: 72012: 32013: 32015: 62016: 62017: 72018: 62019: 42020: 22021: 12022: 42023: 52024: 32025: 82026 (partial year): 2
2007high 8 (2025) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JXG

255in 2025

2007: 184 days median2008: 60 days median2009: 106 days median2010: 30 days median2011: 136 days median2012: 78 days median2013: 108 days median2015: 276 days median2016: 143 days median2017: 90 days median2018: 102 days median2019: 101 days median2022: 101 days median2023: 134 days median2024: 90 days median2025: 255 days median
2007high 276 (2015) · low 30 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JXG

3in 2024

2008: 12009: 302011: 52012: 12013: 142014: 62017: 12020: 82023: 22024: 32026 (partial year): 1
2007high 30 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JXG

1,198in 2025

2007: 6492008: 6302009: 6292010: 8122011: 7872012: 9772013: 1,0042014: 1,2512015: 9842016: 1,0912017: 1,3352018: 1,4842019: 1,2952020: 1,2062021: 1,4672022: 1,3292023: 1,2212024: 1,2142025: 1,198
2007high 1,484 (2018) · low 629 (2009)2025

MAUDE reports naming product code JXG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200731840649
20086601630
2009510630629
20103300812
201171365787
20123781977
20133108141,004
20140—61,251
201562760984
2016614301,091
201779011,335
2018610201,484
2019410101,295
20202—81,206
20211—01,467
2022410101,329
2023513421,221
202439031,214
2025825501,198
20262—1—

What is it indicated for?

The Codman-Medos Connector is for use in the treatment of hydrocepha/us as a component of a shunt system when draining or shunting of cerebrospinal fluid (CSF) is indicated. The Type A Fixation and Joining Connector is indicated for use in the joining and fixation of 1.2 mm nominal /.D. silicone rubber tubing with nonabsorbable sutures in a surgical application. The Type B Fixation and Joining Connector is indicated for use in the joining and fixation of…

Read the full statement (344 words)

The Codman-Medos Connector is for use in the treatment of hydrocepha/us as a component of a shunt system when draining or shunting of cerebrospinal fluid (CSF) is indicated.

The Type A Fixation and Joining Connector is indicated for use in the joining and fixation of 1.2 mm nominal /.D. silicone rubber tubing with nonabsorbable sutures in a surgical application.

The Type B Fixation and Joining Connector is indicated for use in the joining and fixation of 0.8 mm nominal l.D. silicone rubber tubing to 1.2 mm nominal /.D. silicone rubber tubing, and specifically, catalog no. 82-1672, with nonabsorbable sutures in a surgical application.

The Ventriculostomy Reservoir Set is indicated for use to gain access to the cerebral ventricles or other intracranial cavities for the purpose of diagnostic studies or therapeutic drug administration with or without a shunting device. When used with the shunting device, the ventriculostomy reservoir is also indicated for use as the proximal fluid pathway.

The ACCU-FLO Three Way Connector can be utilized as a component in systems designed to shunt cerebrospinal fluid from the lateral ventricles into the right atrium of the heart or the peritoneal cavity, providing they are used in the joining and fixation of approximately 1.3 mm nominal I.D. silicone rubber tubing with nonabsorbable sutures in a surgical application.

The ACCU-FLO Connectors can be utilized as a component in systems designed to shunt cerebrospinal fluid from the lateral ventricles into the right atrium of the heart or the peritoneal cavity, providing they are used in the joining and fixation of approximately 1.3mm nominal /.D. silicone rubber tubing with nonabsorbable sutures in a surgical application.

The Cerebral Catheter-Reservoir is indicated for use as a component of a shunting system to gain access to the cerebral ventricles or other intracranial cavities for the purpose of diagnostic studies, therapeutic drug administration, or the diversion of fluid.

The In-Line Shunt Filter is indicated for use to filter particles that are larger than approximately 3.9 microns when neoplasrn is suspected and when shunting is the procedure of choice in the treatment of hydrocephalus.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K102961: Holter in-Line Shunt Filter, Holter Cerebral Catheter Reservoir, Accu-Flo Connectors; Accu-Flo Three Way Connector; Codm.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K102961

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026