510(k) Report

510(k) · Cleared

Cleared

Hakim Programmable Valve System

K974739510(k) TraditionalCleared Jul 1, 1998194-day reviewClass II21 CFR 882.5550

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Johnson & Johnson Professionals, Inc. · JXG Shunt, Central Nervous System And Components

Cleared on Jul 1, 1998 as substantially equivalent to K944222 (Johnson & Johnson Professionals, Inc., 1995) after a 194-day review. Its family tree reaches back 1 generation to 1995. 1 of the 44 devices in its family, counting itself, has a Class I recall. 42 later devices descend from it.

Decided
Jul 1, 1998
Review
194 days
Class
Class II
Product code
JXG
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K944222 (1995). 42 later devices descend from it, 10 citing it directly. 1 of the 44 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2017: 2 descendants cleared2012: 3 descendants cleared2015: 3 descendants cleared2006: 3 descendants cleared2009: 2 descendants cleared2002: 3 descendants cleared2000: 1 descendant cleared2011: 2 descendants cleared2004: 5 descendants cleared2005: 2 descendants cleared2018: 3 descendants cleared2023: 1 descendant cleared2022: 1 descendant cleared2024: 1 descendant cleared2008: 2 descendants cleared2007: 1 descendant cleared2016: 1 descendant cleared, 1 with a Class I recall12025: 1 descendant cleared2010: 2 descendants cleared2013: 1 descendant cleared2021: 1 descendant cleared2019: 1 descendant clearedK944222 · Codman-Medos Valve Shunt System · Johnson & Johnson Professionals, Inc. · 19951995200020052010201520202025
Descendants, by generation 1 generation forward: 10 descendants2 generations forward: 13 descendants3 generations forward: 9 descendants, 1 with a Class I recall14 generations forward: 9 descendants5 generations forward: 1 descendant K944222 · Codman-Medos Valve Shunt System · Johnson & Johnson Professionals, Inc. · 19950+5
  1. Root · 1 generation backK944222 Codman-Medos Valve Shunt SystemJohnson & Johnson Professionals, Inc. · 1995
  2. This deviceK974739 Hakim Programmable Valve SystemJohnson & Johnson Professionals, Inc. · 1998
  3. Descendant · cites it directly · 29 of its ownK992465 Sophy SU8 Pressure Adjustable ValveSophysa SA · 2000
  4. Descendant · cites it directly · 25 of its ownK012052 Medtronic PS Medical Strata Valve, Models 42855, 42865, 92865, 92855Medtronic PS Medical · 2002
  5. Descendant · 2 generations on · 23 of its ownK033850 Medtronic PS Medical Strata NSC Valve and Shunt Assemblies with and…Medtronic Neurosurgery · 2004 · Recalled
  6. Descendant · 2 generations on · 19 of its ownK042465 PS Medical Strata II ValveMedtronic Neurosurgery · 2004 · Recalled
  7. Descendant · 2 generations on · 9 of its ownK013488 Sophy Pressure Adjustable Valve System Model SM8Sophysa SA · 2002

Showing 5 of 42 descendants. See all descendants

Descendants cleared per year

2000: 12002: 32004: 52005: 22006: 32007: 12008: 22009: 22010: 22011: 22012: 32013: 12015: 32016: 12017: 22018: 32019: 12021: 12022: 12023: 12024: 12025: 1
2000high 5 (2004) · low 0 (2001)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 42 · See all
  • K992465Sophy SU8 Pressure Adjustable ValveSophysa SA · 2000 · cites it directly29descendants
  • K012052Medtronic PS Medical Strata Valve, Models 42855, 42865, 92865, 92855Medtronic PS Medical · 2002 · cites it directly25descendants
  • K033850Medtronic PS Medical Strata NSC Valve and Shunt Assemblies with and Without BioglideMedtronic Neurosurgery · 2004 · 2 generations on23descendants
  • K042465PS Medical Strata II ValveMedtronic Neurosurgery · 2004 · 2 generations on19descendants
  • K013488Sophy Pressure Adjustable Valve System Model SM8Sophysa SA · 2002 · 2 generations on9descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K944222Codman-Medos Valve Shunt SystemJohnson & Johnson Professionals, Inc.1995—
0 (this device)K974739Hakim Programmable Valve SystemJohnson & Johnson Professionals, Inc.1998—
+1K992465Sophy SU8 Pressure Adjustable ValveSophysa SA2000—
+1K012052Medtronic PS Medical Strata Valve, Models 42855, 42865, 92865, 92855Medtronic PS Medical2002—
+2K033850Medtronic PS Medical Strata NSC Valve and Shunt Assemblies with and Without…Medtronic Neurosurgery20042
+2K042465PS Medical Strata II ValveMedtronic Neurosurgery20044
+2K013488Sophy Pressure Adjustable Valve System Model SM8Sophysa SA2002—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200010
200230
200450
200520
200630
200710
200820
200920
201020
201120
201230
201310
201530
201611
201720
201830
201910
202110
202210
202310
202410
202510
FIG. 1 — Lineage of K974739, 1995–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JXG device

  1. #1 K243531 Codman Libertís Shunt Catheter with Bactiseal…score 11.9 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K944222Codman-Medos Valve Shunt System
Summary page 2
…Comparison The HP Valve System is substantially equivalent in terms of intended use, materials, design, manufacturing, and function to the HAKIM Precision Valve System (K944222). Both devices utilize the same ball-in-cone valve mechanism to maintain intraventricular pressure. The valve design maintains in…
Johnson & Johnson Professionals, Inc.1995—

Also cleared against K944222: 7 other devices →

What descends from it? (42)

See all 42

10 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K992465Sophy SU8 Pressure Adjustable ValveSophysa SA200029
K012052Medtronic PS Medical Strata Valve, Models 42855, 42865, 92865, 92855Medtronic PS Medical200225
K020667Codman Hakim Shunt SystemsCodman & Shurtleff, Inc.20028
K053350Modification to Codman Hakim Shunt SystemsCodman & Shurtleff, Inc.20065
K122118Hakim Programmable and Precision Valve Shunt SystemCodman & Shurtleff, Inc.20124
K172022CODMAN Hydrocephalus Valves, Catheters & Accessories (Bundled)Codman & Shurtleff, Inc.20173
K112156Codman Certas Programmable Valve System, Codman Certas Therapy Management SystemMedos International SARL20113
K152152Codman Certas Plus Programmable ValveMedos International SARL20152
K091346Codman Hakim Micro II ValveCodman & Shurtleff, Inc.20090
K053107Codman Hakim Programmable Valve W/WO SiphonguardCodman & Shurtleff, Inc.20060

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K152700StrataMR Valves and ShuntsMedtronic Neurosurgery · 2016 · 3 generations on · ◆ in the 2016 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K992465 (Sophysa SA, 2000) has gone furthest, with 29 descendants of its own.
  • 7 other devices also cite its predicate K944222.

How does its category compare?

All JXG devices

JXG Shunt, Central Nervous System And Components: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JXG

8in 2025

2007: 32008: 62009: 52010: 32011: 72012: 32013: 32015: 62016: 62017: 72018: 62019: 42020: 22021: 12022: 42023: 52024: 32025: 82026 (partial year): 2
2007high 8 (2025) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JXG

255in 2025

2007: 184 days median2008: 60 days median2009: 106 days median2010: 30 days median2011: 136 days median2012: 78 days median2013: 108 days median2015: 276 days median2016: 143 days median2017: 90 days median2018: 102 days median2019: 101 days median2022: 101 days median2023: 134 days median2024: 90 days median2025: 255 days median
2007high 276 (2015) · low 30 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JXG

3in 2024

2008: 12009: 302011: 52012: 12013: 142014: 62017: 12020: 82023: 22024: 32026 (partial year): 1
2007high 30 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JXG

1,198in 2025

2007: 6492008: 6302009: 6292010: 8122011: 7872012: 9772013: 1,0042014: 1,2512015: 9842016: 1,0912017: 1,3352018: 1,4842019: 1,2952020: 1,2062021: 1,4672022: 1,3292023: 1,2212024: 1,2142025: 1,198
2007high 1,484 (2018) · low 629 (2009)2025

MAUDE reports naming product code JXG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200731840649
20086601630
2009510630629
20103300812
201171365787
20123781977
20133108141,004
20140—61,251
201562760984
2016614301,091
201779011,335
2018610201,484
2019410101,295
20202—81,206
20211—01,467
2022410101,329
2023513421,221
202439031,214
2025825501,198
20262—1—

What is it indicated for?

The HP Valve System is an implantable device that provides constant intraventricular pressure and drainage of cerebrospinal fluid (CSF) for the management of hydrocephalus.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K974739: Hakim Programmable Valve System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K974739

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026