510(k) · Cleared
ClearedSterilization Mats
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
STERIS Corporation · KCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories
Cleared on Feb 18, 2011 as substantially equivalent to K013003 (Advanced Sterilization Products, 2002) after a 109-day review. Its family tree reaches back 1 generation to 2002. 8 later devices descend from it.
- Decided
- Feb 18, 2011
- Review
- 109 days
- Class
- Class II
- Product code
- KCT
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K013003 (2002). 8 later devices descend from it, 1 citing it directly.
- Root · 1 generation backK013003 Aptimax Instrument Tray, Instrument Mat and Instrument HolderAdvanced Sterilization Products · 2002
- This deviceK103226 Sterilization MatsSTERIS Corporation · 2011
- Descendant · cites it directly · 7 of its ownK140494 V-Pro Sterilization Tray/ Sterilization MatSTERIS Corporation · 2014
- Descendant · 2 generations on · 6 of its ownK160912 Sterilization TraySTERIS Corporation · 2016
- Descendant · 3 generations on · 5 of its ownK172755 PRO-LITE Sterilization TraysSTERIS Corporation · 2018
- Descendant · 4 generations on · 3 of its ownK183402 PRO-LITE Sterilization TraySTERIS Corporation · 2019
- Descendant · 5 generations on · 2 of its ownK222440 Vis-U-All Low Temperature Sterilization Pouches/Tubing, PRO-LITE…Steris · 2022
Showing 5 of 8 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 8 · See all- K140494V-Pro Sterilization Tray/ Sterilization MatSTERIS Corporation · 2014 · cites it directly7descendants
- K160912Sterilization TraySTERIS Corporation · 2016 · 2 generations on6descendants
- K172755PRO-LITE Sterilization TraysSTERIS Corporation · 2018 · 3 generations on5descendants
- K183402PRO-LITE Sterilization TraySTERIS Corporation · 2019 · 4 generations on3descendants
- K222440Vis-U-All Low Temperature Sterilization Pouches/Tubing, PRO-LITE Sterilization TraysSteris · 2022 · 5 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K013003 | Aptimax Instrument Tray, Instrument Mat and Instrument Holder | Advanced Sterilization Products | 2002 | — |
| 0 (this device) | K103226 | Sterilization Mats | STERIS Corporation | 2011 | — |
| +1 | K140494 | V-Pro Sterilization Tray/ Sterilization Mat | STERIS Corporation | 2014 | — |
| +2 | K160912 | Sterilization Tray | STERIS Corporation | 2016 | — |
| +3 | K172755 | PRO-LITE Sterilization Trays | STERIS Corporation | 2018 | — |
| +4 | K183402 | PRO-LITE Sterilization Tray | STERIS Corporation | 2019 | — |
| +5 | K222440 | Vis-U-All Low Temperature Sterilization Pouches/Tubing, PRO-LITE Sterilization… | Steris | 2022 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2014 | 1 | 0 |
| 2016 | 1 | 0 |
| 2018 | 1 | 0 |
| 2019 | 2 | 0 |
| 2022 | 1 | 0 |
| 2023 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KCT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KCT device
- #1 K214041 Aesculap AICON Containerscore 18.1 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K013003 | Aptimax Instrument Tray, Instrument Mat and Instrument HolderSummary page 2…80.6850 Product Code KCT 2. Predicate Device APTIMAX Instrument Tray, Instrument Tray Holder, and Instrument Tray Mat (K013003) 3. Description of Device The sterilization mats are used to cushion and stabilize devices placed into the V-PRO St… | 2002 |
What descends from it? (8)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K140494 | V-Pro Sterilization Tray/ Sterilization Mat | 2014 | 7 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All KCT devicesKCT Sterilization Wrap Containers, Trays, Cassettes & Other Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · KCT
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KCT
205in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KCT
17in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KCT
50in 2025
MAUDE reports naming product code KCT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 199 | 0 | 2 |
| 2008 | 6 | 182 | 0 | 8 |
| 2009 | 6 | 89 | 0 | 5 |
| 2010 | 12 | 202 | 1 | 3 |
| 2011 | 6 | 117 | 2 | 3 |
| 2012 | 10 | 236 | 0 | 2 |
| 2013 | 8 | 131 | 1 | 6 |
| 2014 | 11 | 169 | 1 | 5 |
| 2015 | 15 | 151 | 0 | 6 |
| 2016 | 12 | 182 | 3 | 16 |
| 2017 | 10 | 211 | 1 | 3 |
| 2018 | 15 | 192 | 0 | 22 |
| 2019 | 18 | 187 | 0 | 15 |
| 2020 | 14 | 134 | 0 | 66 |
| 2021 | 18 | 185 | 1 | 26 |
| 2022 | 11 | 137 | 17 | 8 |
| 2023 | 10 | 94 | 0 | 30 |
| 2024 | 8 | 106 | 0 | 18 |
| 2025 | 11 | 205 | 0 | 50 |
| 2026 | 9 | 122 | 0 | — |
What is it indicated for?
The sterilization mats are intended to be used in conjunction with the V-PROTM Sterilization Trays (K(070769) to cushion and stabilize instruments during sterilization in the Amsco® V-PRO Low Temperature Sterilization Systems. The sterilization mats have been validated for use in the three pre-programmed V-PRO sterilization cycles [Lumen Cycle (the only cycle of the V-PRO I Sterilizer), Non Lumen Cycle, and Flexible Cycle]. The critical parameters for…
Read the full statement (587 words)
The sterilization mats are intended to be used in conjunction with the V-PROTM Sterilization Trays (K(070769) to cushion and stabilize instruments during sterilization in the Amsco® V-PRO Low Temperature Sterilization Systems.
The sterilization mats have been validated for use in the three pre-programmed V-PRO sterilization cycles [Lumen Cycle (the only cycle of the V-PRO I Sterilizer), Non Lumen Cycle, and Flexible Cycle]. The critical parameters for each of these cycles are listed below.
The Lumen Cycle, cleared under K062297, can sterilize:
• Instruments with diffusion-restricted spaces such as the hinged portion of forceps and scissors
• Medical devices with a single stainless steel lumen with:
• an inside diameter of 1 mm or larger and a length of 125 mm or shorter
• an inside diameter of 2 mm or larger and a length of 250 mm or shorter
• an inside diameter of 3 mm or larger and a length of 400 mm or shorter
The validation testing for all lumen sizes was conducted using a maximum of twenty (20) lumens per load. Hospital loads should not exceed the maximum number of lumens validated by this testing. The validation studies were performed using a validation load consisting of two instrument trays (containing two mats and 20 instrument organizers) and two pouches for a total weight of 19.65 lbs.
The Non Lumen Cycle, cleared under K083097, can sterilize:
Non-lumened instruments including non-lumened instruments with stainless steel diffusion-restricted areas such as the hinged portion of forceps or scissors.
The validation studies were conducted using a validation load consisting of two instrument trays containing two mats, and 20 instrument organizers and two pouches for a total weight of 19.65 lbs.
The Flexible Cycle, subject of K102330, can sterilize:
Single or dual lumen surgical flexible endoscopes and bronchoscopes in either of two load configurations:
1. Two flexible endoscopes with a light cord (if not integral to endoscope) and mat with no additional load.
The flexible endoscopes may contain either:
• a single Teflon lumen with an inside diameter of 1 mm or larger and a length of 1050 mm or shorter
• or two Teflon lumens with:
• one lumen having an inside diameter of 1 mm or larger and a length of 998 mm or shorter
• and the other lumen having an inside diameter of 1 mm or larger and a length of 850 mm or shorter
The validation studies were conducted with two flexible endoscopes, each packaged into a tray with silicone mat, 20 instrument organizers and light cord (if not integral to endoscope).
2. One flexible endoscope with a light cord (if not integral to endoscope) and mat and additional non-lumened instruments including instruments with diffusion-restricted areas such as the hinged portion of forceps or scissors.
The flexible endoscope can contain either:
• a single Teflon lumen with an inside diameter of 1 mm or larger and a length of 1050 mm or shorter
• or two Teflon lumens with:
• one lumen having an inside diameter of 1 mm or larger and a length of 998 mm or shorter
• and the other lumen having an inside diameter of 1 mm or larger and a length of 850 mm or shorter
The validation studies were conducted with a flexible endoscope in a tray with silicone mat, 20 instrument organizers and light cord (if not integral to endoscope). Also included in the load were an additional instrument tray (containing a mat and 20 instrument organizers) and one pouch for a total load weight of 24.0 lbs.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K103226 · printed Nov 6, 2026
Cite this page
510(k) Report. “K103226: Sterilization Mats.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K103226
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026