510(k) Report

510(k) · Cleared

Recalled · Class I · 2015

Symbiq Infusion and Adminstration Set

K110901510(k) TraditionalCleared Mar 5, 2012340-day reviewClass II21 CFR 880.5725Recalls 13 (2 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Hospira, Inc. · FRN Pump, Infusion

Cleared on Mar 5, 2012 as substantially equivalent to K041550 (Abbott Laboratories, 2004) after a 340-day review. Its family tree reaches back 3 generations to 2001. 3 of the 7 devices in its family, counting itself, have a Class I recall. 1 later device descends from it. It has been recalled 13 times, including 2 Class I recalls.

Decided
Mar 5, 2012
Review
340 days
Class
Class II
Product code
FRN
Recalls
13 (2 Class I)
Predicates
1

Its longest line of descent runs back 3 generations to K011442 (2001). 5 ancestors in all. 1 later device descends from it, 1 citing it directly. 3 of the 7 devices in this family, counting this one, have a Class I recall.

  1. Root · 3 generations backK011442 Abbott Plum a+Infusion Pump, Model 11971Abbott Laboratories · 2001 · Recalled (Class I)
  2. 2 generations backK031185 Abbott Plum a+ Infusion Pump with a HPL/RS Plug-and-Play ModuleAbbott Laboratories · 2003 · Recalled
  3. 1 generation backK041550 Hospira Phoenix Infusion System with Hospira Mednet SoftwareAbbott Laboratories · 2004 · Recalled (Class I)
  4. This deviceK110901 Symbiq Infusion and Adminstration SetHospira, Inc. · 2012
  5. Descendant · cites it directly · 0 of its ownK121032 Primary Symbiq Set, Dital Microbore Tubing, 0.2 Micron Filter…Hospira, Inc. · 2012

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K121032Primary Symbiq Set, Dital Microbore Tubing, 0.2 Micron Filter, Non-DehpHospira, Inc. · 2012 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K011442Abbott Plum a+Infusion Pump, Model 11971Abbott Laboratories2001Class I
−2K031185Abbott Plum a+ Infusion Pump with a HPL/RS Plug-and-Play ModuleAbbott Laboratories20034
−1K041550Hospira Phoenix Infusion System with Hospira Mednet SoftwareAbbott Laboratories2004Class I
0 (this device)K110901Symbiq Infusion and Adminstration SetHospira, Inc.2012—
+1K121032Primary Symbiq Set, Dital Microbore Tubing, 0.2 Micron Filter, Non-DehpHospira, Inc.2012—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200220

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
FIG. 1 — Lineage of K110901, 2001–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRN device

  1. #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K041550Hospira Phoenix Infusion System with Hospira Mednet Software
Summary page 1
…FRN and FPA Legally marketed device(s) Hospira Phoenix Infusion System with Hospira MedNet to which equivalence is Software, cleared under K041550 on 06/30/2004 claimed Reason for 510(k) Cumulative changes submission Device description Symbiql T…
Abbott Laboratories2004Class I

Also cleared against K041550: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K121032Primary Symbiq Set, Dital Microbore Tubing, 0.2 Micron Filter, Non-DehpHospira, Inc.20120

Has anything in its family been recalled? (3 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Dec 22, 2015Class IIZ-0863-2016Nonconforming Material/ComponentPotential for the Symbiq pole clamp assemblies to be missing the rubber stop pad.
Aug 28, 2013Class IIZ-0372-2014Employee errorHospira shipped the incorrect replaceable battery pack (Part No: HSP3566-E10) instead of the correct E09 battery pack (Part No. HSP3566-E09) for the Symbiq Single and Dual Channel Infusers.
Feb 5, 2013Class IIZ-0353-2017Process controlHospira has received reports of Malfunction S205 Backup Battery Failure alarms in Symbiq v3.13 pumps. This issue to an incorrect installation of components on some of the Power Supply Controller (PSC) Boards distributed prior to September…
Feb 5, 2013Class IIZ-0354-2017Process controlHospira has received reports of Malfunction S205 Backup Battery Failure alarms in Symbiq v3.13 pumps. This issue to an incorrect installation of components on some of the Power Supply Controller (PSC) Boards distributed prior to September…
Feb 4, 2013Class IIZ-0306-2017Software designSymbiq Infusers have the potential to experience a white screen during titration of a Keep Vein Open (KVO) delivery. This can allow the clinician to select the "NEXT" button prior to completion of the programming. If this error occurs, a…
Feb 4, 2013Class IIZ-0305-2017Software designSymbiq Infusers have the potential to experience a white screen during titration of a Keep Vein Open (KVO) delivery. This can allow the clinician to select the "NEXT" button prior to completion of the programming. If this error occurs, a…
Feb 4, 2013Class IIZ-2056-2016Software designFrequent Proximal Occlusion Alarms (POAs) occurring on Symbiq devices with list numbers 16026 and 16027. When there are false alarms, the pump will continue to alarm even though there is no occlusion present. False POAs could result in a…
Feb 4, 2013Class IIZ-1847-2013Process controlThe devices secondary audio signal fails to activate.
Feb 4, 2013Class IIZ-2055-2016Software designFrequent Proximal Occlusion Alarms (POAs) occurring on Symbiq devices with list numbers 16026 and 16027. When there are false alarms, the pump will continue to alarm even though there is no occlusion present. False POAs could result in a…
Aug 29, 2012Class IZ-0069-2013Device DesignThe Symbiq pump touchscreen may not respond to user selection, may experience a delayed response, or may register a different value from the value selected by the user. Failure of the touchscreen to respond to user input could result in a…
Aug 29, 2012Class IZ-0070-2013Device DesignThe Symbiq pump touchscreen may not respond to user selection, may experience a delayed response, or may register a different value from the value selected by the user. Failure of the touchscreen to respond to user input could result in a…
Mar 16, 2011Class IIZ-0362-2017Device DesignMay go to a white screen due to a problem with the SOM2 module. A white screen is a diagnostic screen displayed to the user as part of the safety shutdown procedure of the device. The infusion and the processor stop, sound a 3 minute…
Mar 16, 2011Class IIZ-0361-2017Device DesignMay go to a white screen due to a problem with the SOM2 module. A white screen is a diagnostic screen displayed to the user as part of the safety shutdown procedure of the device. The infusion and the processor stop, sound a 3 minute…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K041550Hospira Phoenix Infusion System with Hospira Mednet SoftwareAbbott Laboratories · 2004 · Direct predicate · ◆ on the line of descent in FIG. 12 Class I recalls
  • K011442Abbott Plum a+Infusion Pump, Model 11971Abbott Laboratories · 2001 · 3 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 11 years and passes through 2 companies; a new generation was cleared every 1.9 years on median.
  • 4 of the 5 ancestors have a recall of any class; 2 have a Class I recall.
  • Of its descendants, K121032 (Hospira, Inc., 2012) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K041550.

How does its category compare?

All FRN devices

FRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · FRN

8in 2025

2007: 122008: 82009: 92010: 32011: 32012: 42013: 62014: 62015: 32016: 32017: 32018: 32019: 22020: 12021: 22022: 62023: 72024: 52025: 82026 (partial year): 2
2007high 12 (2007) · low 1 (2020)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRN

172in 2025

2007: 102 days median2008: 89 days median2009: 66 days median2010: 93 days median2011: 103 days median2012: 217 days median2013: 312 days median2014: 172 days median2015: 232 days median2016: 301 days median2017: 305 days median2018: 267 days median2022: 268 days median2023: 265 days median2024: 103 days median2025: 172 days median
2007high 312 (2013) · low 66 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRN

7in 2025

2007: 152008: 242009: 1022010: 372011: 692012: 42, 2 Class I2013: 22, 3 Class I2014: 4, 3 Class I2015: 52016: 7, 1 Class I2017: 132018: 12019: 18, 1 Class I2020: 16, 5 Class I2021: 3, 2 Class I2022: 22023: 16, 10 Class I2024: 9, 4 Class I2025: 7, 4 Class I2026 (partial year): 11, 2 Class I
2007high 102 (2009) · low 1 (2018)2026

Class I (37 since 2007) Class II/III not classified

Adverse event reports per year · FRN

52,792in 2025

2007: 1,0862008: 8,2612009: 1,9522010: 6,1332011: 41,3672012: 15,4822013: 40,0822014: 94,1802015: 26,7422016: 16,5602017: 12,0602018: 16,5912019: 15,8502020: 94,1862021: 199,3422022: 888,0202023: 165,8382024: 57,7302025: 52,792
2007high 888,020 (2022) · low 1,086 (2007)2025

MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200712102151,086
2008889248,261
20099661021,952
2010393376,133
201131036941,367
2012421742 (2)15,482
2013631222 (3)40,082
201461724 (3)94,180
20153232526,742
201633017 (1)16,560
201733051312,060
20183267116,591
20192—18 (1)15,850
20201—16 (5)94,186
20212—3 (2)199,342
202262682888,020
2023726516 (10)165,838
202451039 (4)57,730
202581727 (4)52,792
20262—11 (2)—

What is it indicated for?

The SymbiqTM Infusion System is intended for the delivery of fluids, solutions, drugs, agents, nutritionals, electrolytes, blood and blood products via parenteral, enteral, intravenous, intra-arterial, subcutaneous, epidural or irrigation routes of administration.

It is intended primarily for use in the hospital setting and can be used in other acute and non-acute care areas, such as, but not limited to Nursing Homes, Mobile Intensive Care, Ambulatory Infusion Centers, Hospice, Subacute Facilities, Outpatient/Surgical Centers, Long Term Care, Urgent Care, Transport and Physician Offices.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K110901: Symbiq Infusion and Adminstration Set.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K110901

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026