Reverse Shoulder Monoblock Prosthesis (RSP)

K111061510(k) SpecialCleared Jul 20, 201193-day reviewClass II21 CFR 888.3660

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Encore Medical L.P. · PHX Shoulder Prosthesis, Reverse Configuration

Cleared on Jul 20, 2011 as substantially equivalent to K041066 (Encore Medical L.P., 2005) and 2 other predicates after a 93-day review. Its family tree reaches back 4 generations to 2005. 19 later devices descend from it.

Decided
Jul 20, 2011
Review
93 days
Class
Class II
Product code
PHX
Recalls
None
Predicates
3

Its longest line of descent runs back 4 generations to K041066 (2005). 19 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2017: 1 descendant cleared2020: 1 descendant cleared2022: 4 descendants cleared2021: 4 descendants cleared2019: 1 descendant cleared2025: 3 descendants cleared2024: 2 descendants cleared2023: 2 descendants cleared2026: 1 descendant cleared×2: 2 generations cleared close together, K041066 (2005), K051075 (2005) K092873 · Reverse Shoulder Prosthesis · Djo Surgical · 2009K100741 · Reverse Shoulder Prosthesis Monoblock Stem, Reverse Shoulder Prosthesis Humeral Inserts, Model 510-00-006/012 · Encore Medical L.P. · 2010 · recalled20052010201520202025
  1. Root · 4 generations backK041066 Encore Reverse Shoulder ProsthesisEncore Medical L.P. · 2005 · Recalled
  2. 3 generations backK051075 Encore Reverse Shoulder ProsthesisEncore Medical L.P. · 2005 · Recalled
  3. 2 generations backK092873 Reverse Shoulder ProsthesisDjo Surgical · 2009
  4. 1 generation backK100741 Reverse Shoulder Prosthesis Monoblock Stem, Reverse Shoulder…Encore Medical L.P. · 2010 · Recalled
  5. This deviceK111061 Reverse Shoulder Monoblock Prosthesis (RSP)Encore Medical L.P. · 2011
  6. Descendant · cites it directly · 18 of its ownK172351 AltiVate Reverse Humeral Stem, AltiVate Reverse Small Spacer…Encore Medical L.P. · 2017 · Recalled
  7. Descendant · 2 generations on · 15 of its ownK190290 AltiVate Reverse Humeral Stem, 48mmEncore Medical L.P. · 2019
  8. Descendant · 2 generations on · 5 of its ownK202611 Catalyst OrthoScience R1 Reverse Shoulder SystemCatalyst Orthoscience, Inc. · 2021
  9. Descendant · 3 generations on · 3 of its ownK211991 Catalyst R1 Reverse Shoulder SystemCatalyst Orthoscience, Inc. · 2021
  10. Descendant · 3 generations on · 2 of its ownK213349 Catalyst R1 Reverse Shoulder SystemCatalyst Orthoscience, Inc. · 2022

Showing 5 of 19 descendants. See all descendants

Descendants cleared per year

2017: 12019: 12020: 12021: 42022: 42023: 22024: 22025: 32026: 1
2017high 4 (2021) · low 0 (2018)2026

Most influential descendants

Showing 5 of 19 · See all
  • K172351AltiVate Reverse Humeral Stem, AltiVate Reverse Small Spacer, Altivate Reverse, Small…Encore Medical L.P. · 2017 · cites it directly18descendants
  • K190290AltiVate Reverse Humeral Stem, 48mmEncore Medical L.P. · 2019 · 2 generations on15descendants
  • K202611Catalyst OrthoScience R1 Reverse Shoulder SystemCatalyst Orthoscience, Inc. · 2021 · 2 generations on5descendants
  • K211991Catalyst R1 Reverse Shoulder SystemCatalyst Orthoscience, Inc. · 2021 · 3 generations on3descendants
  • K213349Catalyst R1 Reverse Shoulder SystemCatalyst Orthoscience, Inc. · 2022 · 3 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K041066Encore Reverse Shoulder ProsthesisEncore Medical L.P.20054
−3K051075Encore Reverse Shoulder ProsthesisEncore Medical L.P.20055
−2K092873Reverse Shoulder ProsthesisDjo Surgical2009—
−1K100741Reverse Shoulder Prosthesis Monoblock Stem, Reverse Shoulder Prosthesis…Encore Medical L.P.20101
0 (this device)K111061Reverse Shoulder Monoblock Prosthesis (RSP)Encore Medical L.P.2011—
+1K172351AltiVate Reverse Humeral Stem, AltiVate Reverse Small Spacer, Altivate…Encore Medical L.P.20173
+2K190290AltiVate Reverse Humeral Stem, 48mmEncore Medical L.P.2019—
+2K202611Catalyst OrthoScience R1 Reverse Shoulder SystemCatalyst Orthoscience, Inc.2021—
+3K211991Catalyst R1 Reverse Shoulder SystemCatalyst Orthoscience, Inc.2021—
+3K213349Catalyst R1 Reverse Shoulder SystemCatalyst Orthoscience, Inc.2022—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
201910
202010
202140
202240
202320
202420
202530
202610
FIG. 1 — Lineage of K111061, 2005–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PHX device

  1. #1 K212737 INHANCE™ Reverse Shoulder Systemscore 28.4 · 15 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K041066Encore Reverse Shoulder Prosthesis
Summary page 4
…ication with the addition of screws for fixation. The humeral stem is intended for cemented use only. ‘ ' Predicate Device: o DJO Surgical Reverse Shoulder Prosthesis — K041066, K051075, K 100741 Comparable Features to Predicate Device(s): Features comparable to predicate devices include the same design…
Encore Medical L.P.20054
*K051075Encore Reverse Shoulder Prosthesis
Summary page 4
…ith the addition of screws for fixation. The humeral stem is intended for cemented use only. ‘ ' Predicate Device: o DJO Surgical Reverse Shoulder Prosthesis — K041066, K051075, K 100741 Comparable Features to Predicate Device(s): Features comparable to predicate devices include the same design features,…
Encore Medical L.P.20055
*K100741Reverse Shoulder Prosthesis Monoblock Stem, Reverse Shoulder Prosthesis Humeral Inserts…
Summary page 4
…cation Name KWS Shoulder joint metal/polymer semi-constrained prosthesis per 21 CFR 888.3660 Description: This is a modification to the RSP Monoblock Stem cleared under K100741. The cleared RSP Monoblock Prosthesis system consists of a monoblock humeral stem with socket, humeral socket inserts, glenoid he…
Encore Medical L.P.20101

Also cleared against K041066: 24 other devices →

What descends from it? (19)

See all 19

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K172351AltiVate Reverse Humeral Stem, AltiVate Reverse Small Spacer, Altivate Reverse, Small…Encore Medical L.P.201718

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 6 years and passes through 2 companies; a new generation was cleared every 12 months on median.
  • 3 of the 4 ancestors have a recall of any class.
  • Of its descendants, K172351 (Encore Medical L.P., 2017) has gone furthest, with 18 descendants of its own.
  • 24 other devices also cite its predicate K041066.

How does its category compare?

All PHX devices

PHX Shoulder Prosthesis, Reverse Configuration: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · PHX

9in 2025

2007: 52008: 62009: 12010: 82011: 122012: 122013: 82014: 122015: 42016: 42017: 112018: 142019: 92020: 132021: 212022: 92023: 92024: 92025: 92026 (partial year): 18
2007high 21 (2021) · low 1 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PHX

72in 2025

2007: 97 days median2008: 79 days median2010: 124 days median2011: 94 days median2012: 114 days median2013: 143 days median2014: 110 days median2015: 206 days median2016: 132 days median2017: 141 days median2018: 127 days median2019: 144 days median2020: 143 days median2021: 143 days median2022: 198 days median2023: 154 days median2024: 139 days median2025: 72 days median2026 (partial year): 130 days median
2007high 206 (2015) · low 72 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PHX

3in 2025

2015: 22018: 12019: 32020: 32021: 82023: 72024: 12025: 32026 (partial year): 7
2007high 8 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PHX

2,848in 2025

2015: 142016: 52017: 252018: 3232019: 5042020: 9862021: 1,4042022: 1,3422023: 1,4012024: 2,1422025: 2,848
2007high 2,848 (2025) · low 0 (2007)2025

MAUDE reports naming product code PHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200759700
200867900
20091—00
2010812400
2011129400
20121211400
2013814300
20141211000
20154206214
2016413205
201711141025
2018141271323
201991443504
2020131433986
20212114381,404
2022919801,342
2023915471,401
2024913912,142
202597232,848
2026181307—

What is it indicated for?

The Reverse Shoulder Monoblock Prosthesis is indicated for patients with a functional deltoid muscle with a grossly deficient rotator cuff shoulder joint with severe arthropathy or a previously failed joint replacement with a grossly deficient rotator cuff shoulder joint: In cases of fracture of glenohumeral joint from trauma or pathologic conditions of the shoulder, including humeral head fracture or displaced 3-or 4-part fractures of proximal humerus.…

Read the full statement (112 words)

The Reverse Shoulder Monoblock Prosthesis is indicated for patients with a functional deltoid muscle

with a grossly deficient rotator cuff shoulder joint with severe arthropathy or a previously failed joint

replacement with a grossly deficient rotator cuff shoulder joint:

In cases of fracture of glenohumeral joint from trauma or pathologic conditions of the shoulder,

including humeral head fracture or displaced 3-or 4-part fractures of proximal humerus.

In cases of bone defect in proximal humerus.

The patient’s joint must be anatomically and structurally suited to receive the selected implant(s).

The glenoid baseplate is intended for cementless application with the addition of screws for fixation. The

humeral stem is intended for cemented use only.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K111061: Reverse Shoulder Monoblock Prosthesis (RSP).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K111061

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026