510(k) Report

510(k) · Cleared

Cleared

Poly-Chem 90 Total Bilirubin

K111143510(k) TraditionalCleared Sep 1, 2011132-day reviewClass II21 CFR 862.1110

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Polymedco, Inc. · CIG Diazo Colorimetry, Bilirubin

Cleared on Sep 1, 2011 as substantially equivalent to K973995 (Randox Laboratories, Ltd., 1997) after a 132-day review. Its family tree reaches back 1 generation to 1997.

Decided
Sep 1, 2011
Review
132 days
Class
Class II
Product code
CIG
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K973995 (1997). No later device cites it as a predicate yet.

K973995 · Randox Bilirubin · Randox Laboratories, Ltd. · 19971995200020052010
K973995 · Randox Bilirubin · Randox Laboratories, Ltd. · 19970
  1. Root · 1 generation backK973995 Randox BilirubinRandox Laboratories, Ltd. · 1997
  2. This deviceK111143 Poly-Chem 90 Total BilirubinPolymedco, Inc. · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K973995Randox BilirubinRandox Laboratories, Ltd.1997—
0 (this device)K111143Poly-Chem 90 Total BilirubinPolymedco, Inc.2011—
FIG. 1 — Lineage of K111143, 1997–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CIG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CIG device

  1. #1 K251998 Atellica CH Diazo Total Bilirubin (D_TBil)score 11.8 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K973995Randox Bilirubin
Summary page 1
…1110 Classification: Class 11 Predicate Device: Poly-Chem® Total Bilrubin Device common name: Total Bilirubin reagent/test system 5 10(k) number: K973995 Manufacturer: Randox Laboratories Ltd., 55 Diamond Road, Crumlin, Co. Antr…
Randox Laboratories, Ltd.1997—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.

How does its category compare?

All CIG devices

CIG Diazo Colorimetry, Bilirubin: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · CIG

2in 2023

2007: 12008: 32009: 22010: 12011: 22013: 52015: 12017: 12019: 12022: 12023: 22026 (partial year): 1
2007high 5 (2013) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CIG

64in 2013

2008: 199 days median2013: 64 days median
2007high 199 (2008) · low 64 (2013)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CIG

1in 2019

2009: 32013: 32019: 1
2007high 3 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CIG

52in 2025

2007: 22008: 82009: 32010: 62011: 382012: 142013: 82014: 32015: 72016: 42017: 112018: 232019: 252020: 312021: 222022: 262023: 342024: 392025: 52
2007high 52 (2025) · low 2 (2007)2025

MAUDE reports naming product code CIG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—02
2008319908
20092—33
20101—06
20112—038
20120—014
201356438
20140—03
20151—07
20160—04
20171—011
20180—023
20191—125
20200—031
20210—022
20221—026
20232—034
20240—039
20250—052
20261—0—

What is it indicated for?

Poly-Chem 90 Total Bilirubin is for the quantitative in vitro measurement of the level of total bilirubin in human serum on the Poly-Chem 90 clinical chemistry analyzer. Measurements of the level of bilirubin, an organic compound formed during the normal and abnormal destruction of red blood cells, is used in the diagnosis and treatment of liver, hemolytic hemnatological, and metabolic disorders, including hepatitis and gall bladder block.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K111143: Poly-Chem 90 Total Bilirubin.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K111143

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026