K111676510(k) TraditionalCleared Sep 30, 2011107-day reviewClass II21 CFR 892.5710Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Elekta Limited · IXI Block, Beam-Shaping, Radiation Therapy

Cleared on Sep 30, 2011 as substantially equivalent to K001163 (3D Line USA, Inc., 2000) after a 107-day review. Its family tree reaches back 1 generation to 2000. It has been recalled once.

Decided
Sep 30, 2011
Review
107 days
Class
Class II
Product code
IXI
Recalls
1
Predicates
1

Its longest line of descent runs back 1 generation to K001163 (2000). No later device cites it as a predicate yet.

K001163 · DMLC IV-Ergo · 3D Line USA, Inc. · 2000 · recalled2000200220042006200820102012
K001163 · DMLC IV-Ergo · 3D Line USA, Inc. · 2000 · recalled0
  1. Root · 1 generation backK001163 DMLC IV-Ergo3D Line USA, Inc. · 2000 · Recalled
  2. This deviceK111676 APEXElekta Limited · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K001163DMLC IV-Ergo3D Line USA, Inc.20003
0 (this device)K111676APEXElekta Limited2011—
FIG. 1 — Lineage of K111676, 2000–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IXI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IXI device

  1. #1 K253025 Ricoh 3D for Healthcare Bolusscore 12.9 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K001163DMLC IV-Ergo
Summary page 1
…rade Name: Apex™ | Common Name: Add-on microMLC Classification Name: BLOCK, BEAM-SHAPING, RADIATION THERAPY (21CFR 892 5710, Product Code 1XI) Predicate Device: DMLC IV (K001163) Product Description: This Traditional 510(k) describes medifications made to the add-on DMLC accessory for the Elekta range of…
3D Line USA, Inc.20003

Also cleared against K001163: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 18, 2013Class IIZ-0885-2013Employee errorIf the Apex collimator is incorrectly installed on the radiation head, a touchguard inhibit activates the view restrictions dialog box only shows the top 12 restrictions.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • 4 other devices also cite its predicate K001163.

How does its category compare?

All IXI devices

IXI Block, Beam-Shaping, Radiation Therapy: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · IXI

2in 2022

2007: 22009: 32011: 22012: 12013: 32022: 22026 (partial year): 1
2007high 3 (2009) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IXI

90in 2013

2009: 78 days median2013: 90 days median
2007high 90 (2013) · low 78 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IXI

2in 2013

2008: 12011: 12012: 12013: 2
2007high 2 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IXI

1in 2016

2010: 12011: 282012: 32013: 22014: 12016: 1
2007high 28 (2011) · low 0 (2007)2025

MAUDE reports naming product code IXI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20080—10
200937800
20100—01
20112—128
20121—13
201339022
20140—01
20150—00
20160—01
20170—00
20180—00
20190—00
20200—00
20210—00
20222—00
20230—00
20240—00
20250—00
20261—0—

What is it indicated for?

Apex Is an add-on microMLC system. It is an accessory to the linear accelerator used for radiation therapy and it is intended to shape the X-ray field both in static (fixed) or dynamic mode with rotating gantry as a function of the gantry angle. It is provided to assist the radiation oncologist to deliver radiation to the target tissue while sparing the surrounding normal tissues.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K111676: APEX.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K111676

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026