Quadrox-I Microporporous Membrane Oxgenator Series and Qudrox-ID Diffusion Membrane Oxygenators Series

K112360510(k) SpecialCleared Sep 15, 201129-day reviewClass II21 CFR 870.4350Recalls 12

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Maquet Cardiopulmonary, AG · DTZ Oxygenator, Cardiopulmonary Bypass

Cleared on Sep 15, 2011 as substantially equivalent to K082117 (Maquet Cardiopulmonary, AG, 2009) and 8 other predicates after a 29-day review. Its family tree reaches back 9 generations to 1992. 1 of the 49 devices in its family, counting itself, has a Class I recall. It has been recalled 12 times.

Decided
Sep 15, 2011
Review
29 days
Class
Class II
Product code
DTZ
Recalls
12
Predicates
10

Its longest line of descent runs back 9 generations to K922933 (1992). 48 ancestors in all, the oldest K842908 (1985). No later device cites it as a predicate yet. 1 of the 49 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year cleared 2011: 2 other ancestors, 1 with a Class I recall12010: 2 other ancestors2009: 2 other ancestors2008: 3 other ancestors2007: 1 other ancestor2005: 1 other ancestor2003: 2 other ancestors2002: 1 other ancestor2000: 5 other ancestors1995: 2 other ancestors2006: 3 other ancestors2001: 3 other ancestors1999: 3 other ancestors1996: 1 other ancestor1994: 2 other ancestors1985: 1 other ancestor1993: 2 other ancestors1998: 2 other ancestors1992: 1 other ancestorK922933 · Sorin Monolyrh Integrated Membrane Lung · Sorin Biomedica, Fiat, USA, Inc. · 1992K980600 · D903 Avant Adult Hollow Fiber Oxygenator · Dideco S.P.A. · 1998K020351 · D 903 Avant 2 PH.I.S.I.O. Adult Hollow Fiber Oxygenator · Dideco S.P.A. · 2002K022450 · Integrated Unit: Synthesis: Adult Membrane Oxygenator with Integrated Arterial Filter and Hardhshell Venous/Cardiotomy · Dideco S.P.A. · 2002K031223 · Synthesis Mimesys Adult Membrane Oxygenator · Dideco S.P.A. · 2003K073380 · Synthesis PH.I.S.I.O. Adult Membrane Oxygenator with Integrated Areterial Filter and Hardshell Venous/Cariotomy Reservoi · Sorin Group Italia S.R.L. · 2008 · recalledK082117 · Quadrox-I Adult with and Without Integrated Arterial Filter with Softline Coating, Model# Hmo 70000, Hmo 71000 · Maquet Cardiopulmonary, AG · 2009 · recalledK090511 · Quadrox-I Adult Microporous Membrane Oxygenator with Bioline Coating, Model BEHMO70000,Beq-HMO70000 · Maquet Cardiopulmonary, AG · 2009 · recalledK093522 · Quadrox-I Small Adult Microporous Membrane Oxygenator; W/ Bioline Coating and W/ Integrated Arterial Filter W/ Bioline C · Maquet Cardiopulmonary, AG · 2009 · recalled198519901995200020052010
Other ancestors, by generation 1 generation back: 6 other ancestors, 1 with a Class I recall12 generations back: 9 other ancestors3 generations back: 10 other ancestors4 generations back: 9 other ancestors5 generations back: 3 other ancestors6 generations back: 2 other ancestors K093522 · Quadrox-I Small Adult Microporous Membrane Oxygenator; W/ Bioline Coating and W/ Integrated Arterial Filter W/ Bioline C · Maquet Cardiopulmonary, AG · 2009 · recalledK090511 · Quadrox-I Adult Microporous Membrane Oxygenator with Bioline Coating, Model BEHMO70000,Beq-HMO70000 · Maquet Cardiopulmonary, AG · 2009 · recalledK082117 · Quadrox-I Adult with and Without Integrated Arterial Filter with Softline Coating, Model# Hmo 70000, Hmo 71000 · Maquet Cardiopulmonary, AG · 2009 · recalledK073380 · Synthesis PH.I.S.I.O. Adult Membrane Oxygenator with Integrated Areterial Filter and Hardshell Venous/Cariotomy Reservoi · Sorin Group Italia S.R.L. · 2008 · recalledK031223 · Synthesis Mimesys Adult Membrane Oxygenator · Dideco S.P.A. · 2003K022450 · Integrated Unit: Synthesis: Adult Membrane Oxygenator with Integrated Arterial Filter and Hardhshell Venous/Cardiotomy · Dideco S.P.A. · 2002K020351 · D 903 Avant 2 PH.I.S.I.O. Adult Hollow Fiber Oxygenator · Dideco S.P.A. · 2002K980600 · D903 Avant Adult Hollow Fiber Oxygenator · Dideco S.P.A. · 1998K922933 · Sorin Monolyrh Integrated Membrane Lung · Sorin Biomedica, Fiat, USA, Inc. · 1992−50
  1. Root · 9 generations backK922933 Sorin Monolyrh Integrated Membrane LungSorin Biomedica, Fiat, USA, Inc. · 1992
  2. 5 generations between
  3. 3 generations backK082117 Quadrox-I Adult with and Without Integrated Arterial Filter with…Maquet Cardiopulmonary, AG · 2009 · Recalled
  4. 2 generations backK090511 Quadrox-I Adult Microporous Membrane Oxygenator with Bioline…Maquet Cardiopulmonary, AG · 2009 · Recalled
  5. 1 generation backK093522 Quadrox-I Small Adult Microporous Membrane Oxygenator; W/ Bioline…Maquet Cardiopulmonary, AG · 2009 · Recalled
  6. This deviceK112360 Quadrox-I Microporporous Membrane Oxgenator Series and Qudrox-ID…Maquet Cardiopulmonary, AG · 2011
Show all 9 generations
  1. Root · 9 generations backK922933 Sorin Monolyrh Integrated Membrane LungSorin Biomedica, Fiat, USA, Inc. · 1992
  2. 8 generations backK980600 D903 Avant Adult Hollow Fiber OxygenatorDideco S.P.A. · 1998
  3. 7 generations backK020351 D 903 Avant 2 PH.I.S.I.O. Adult Hollow Fiber OxygenatorDideco S.P.A. · 2002
  4. 6 generations backK022450 Integrated Unit: Synthesis: Adult Membrane Oxygenator with…Dideco S.P.A. · 2002
  5. 5 generations backK031223 Synthesis Mimesys Adult Membrane OxygenatorDideco S.P.A. · 2003
  6. 4 generations backK073380 Synthesis PH.I.S.I.O. Adult Membrane Oxygenator with Integrated…Sorin Group Italia S.R.L. · 2008 · Recalled
  7. 3 generations backK082117 Quadrox-I Adult with and Without Integrated Arterial Filter with…Maquet Cardiopulmonary, AG · 2009 · Recalled
  8. 2 generations backK090511 Quadrox-I Adult Microporous Membrane Oxygenator with Bioline…Maquet Cardiopulmonary, AG · 2009 · Recalled
  9. 1 generation backK093522 Quadrox-I Small Adult Microporous Membrane Oxygenator; W/ Bioline…Maquet Cardiopulmonary, AG · 2009 · Recalled
  10. This deviceK112360 Quadrox-I Microporporous Membrane Oxgenator Series and Qudrox-ID…Maquet Cardiopulmonary, AG · 2011

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K922933Sorin Monolyrh Integrated Membrane LungSorin Biomedica, Fiat, USA, Inc.1992—
−8K980600D903 Avant Adult Hollow Fiber OxygenatorDideco S.P.A.1998—
−7K020351D 903 Avant 2 PH.I.S.I.O. Adult Hollow Fiber OxygenatorDideco S.P.A.2002—
−6K022450Integrated Unit: Synthesis: Adult Membrane Oxygenator with Integrated Arterial…Dideco S.P.A.2002—
−5K031223Synthesis Mimesys Adult Membrane OxygenatorDideco S.P.A.2003—
−4K073380Synthesis PH.I.S.I.O. Adult Membrane Oxygenator with Integrated Areterial…Sorin Group Italia S.R.L.20081
−3K082117Quadrox-I Adult with and Without Integrated Arterial Filter with Softline…Maquet Cardiopulmonary, AG20095
−2K090511Quadrox-I Adult Microporous Membrane Oxygenator with Bioline Coating, Model…Maquet Cardiopulmonary, AG20093
−1K093522Quadrox-I Small Adult Microporous Membrane Oxygenator; W/ Bioline Coating and…Maquet Cardiopulmonary, AG20093
0 (this device)K112360Quadrox-I Microporporous Membrane Oxgenator Series and Qudrox-ID Diffusion…Maquet Cardiopulmonary, AG2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
199210
199320
199420
199520
199610
199820
199930
200050
200130
200210
200320
200510
200630
200710
200830
200920
201020
201121
FIG. 1 — Lineage of K112360, 1992–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DTZ device

  1. #1 K240934 Quantum Perfusion Blood Oxygenator ECC…score 14.3 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (10)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
*K082117Quadrox-I Adult with and Without Integrated Arterial Filter with Softline Coating…
Summary page 1
…, arterial line, non-roller type cardiopulmonary bypass. LEGALLY MARKETED MAQUET PREDICATE DEVICES QUADROX-i Adult Microporous Membrane Oxygenators K082117 & K090511, QUADROX-i Small Adult Microporous Membrane Oxygenators K090689 & K093522, QUADROX-i Pediatric Microporous Membrane Oxy…
Maquet Cardiopulmonary, AG20095
*K090511Quadrox-I Adult Microporous Membrane Oxygenator with Bioline Coating, Model…
Summary page 1
…line, non-roller type cardiopulmonary bypass. LEGALLY MARKETED MAQUET PREDICATE DEVICES QUADROX-i Adult Microporous Membrane Oxygenators K082117 & K090511, QUADROX-i Small Adult Microporous Membrane Oxygenators K090689 & K093522, QUADROX-i Pediatric Microporous Membrane Oxygenator K1…
Maquet Cardiopulmonary, AG20093
*K090689Quadrox-I Small Adult with and Without Intergrated Arterial Filter with Softline…
Summary page 1
…s. LEGALLY MARKETED MAQUET PREDICATE DEVICES QUADROX-i Adult Microporous Membrane Oxygenators K082117 & K090511, QUADROX-i Small Adult Microporous Membrane Oxygenators K090689 & K093522, QUADROX-i Pediatric Microporous Membrane Oxygenator K103191, QUADROX-i Neonatal Microporous Membrane Oxygenator K10246…
Maquet Cardiopulmonary, AG20095
*K093522Quadrox-I Small Adult Microporous Membrane Oxygenator; W/ Bioline Coating and W/…
Summary page 1
…LY MARKETED MAQUET PREDICATE DEVICES QUADROX-i Adult Microporous Membrane Oxygenators K082117 & K090511, QUADROX-i Small Adult Microporous Membrane Oxygenators K090689 & K093522, QUADROX-i Pediatric Microporous Membrane Oxygenator K103191, QUADROX-i Neonatal Microporous Membrane Oxygenator K102464, QUADROX…
Maquet Cardiopulmonary, AG20093
*K103191Quadrox-I Pediatric Microporous Membrane Oxygenator with Integrated Arterial Filter with…
Summary page 1
…ous Membrane Oxygenators K082117 & K090511, QUADROX-i Small Adult Microporous Membrane Oxygenators K090689 & K093522, QUADROX-i Pediatric Microporous Membrane Oxygenator K103191, QUADROX-i Neonatal Microporous Membrane Oxygenator K102464, QUADROX-iD Adult Diffusion Membrane Oxygenator Ki101153, QUADROX-iD…
Maquet Cardiopulmonary, AG20114
*K102464Quadrox-I Neonatal Microporous Membrane Oxygenator with Integrated Arterial Filter with…
Summary page 1
…Adult Microporous Membrane Oxygenators K090689 & K093522, QUADROX-i Pediatric Microporous Membrane Oxygenator K103191, QUADROX-i Neonatal Microporous Membrane Oxygenator K102464, QUADROX-iD Adult Diffusion Membrane Oxygenator Ki101153, QUADROX-iD Pediatric Diffusion Membrane Oxygenator K100278, QUADROX-iR…
Maquet Cardiopulmonary, AG2011Class I
*K101153Quadrox-ID Adult Diffusion Membrane Oxygenator with Softline Coating, Model: BE-Hmod…
Summary page 1
…QUADROX-i Pediatric Microporous Membrane Oxygenator K103191, QUADROX-i Neonatal Microporous Membrane Oxygenator K102464, QUADROX-iD Adult Diffusion Membrane Oxygenator Ki101153, QUADROX-iD Pediatric Diffusion Membrane Oxygenator K100278, QUADROX-iR Adult K102627, QUADROX-iR Small Adult K102627, HLS module…
Maquet Cardiopulmonary, AG20104
*K100278Quadrox-ID Pediatric Diffusion Membrane Oxygenator with Bioline Coating, Models BE-Hmod…
Summary page 1
…, QUADROX-i Neonatal Microporous Membrane Oxygenator K102464, QUADROX-iD Adult Diffusion Membrane Oxygenator Ki101153, QUADROX-iD Pediatric Diffusion Membrane Oxygenator K100278, QUADROX-iR Adult K102627, QUADROX-iR Small Adult K102627, HLS modules K102627 and PLEGIOX Cardioplegia Heat Exchanger K090555.…
Maquet Cardiopulmonary, AG20104
Kept off the family treeK102627QUADROX-iR Adult
Not in FDA’s 510(k), De Novo or PMA lists as we hold them (a misreading, a typo, or a number FDA does not list), so it is kept off the family tree
Summary page 1
…porous Membrane Oxygenator K102464, QUADROX-iD Adult Diffusion Membrane Oxygenator Ki101153, QUADROX-iD Pediatric Diffusion Membrane Oxygenator K100278, QUADROX-iR Adult K102627, QUADROX-iR Small Adult K102627, HLS modules K102627 and PLEGIOX Cardioplegia Heat Exchanger K090555.…
*K090555Plegiox Cardioplegia Heat Exchanger with Softline Coating, Model Bio-CHX 30
Summary page 1
…iD Pediatric Diffusion Membrane Oxygenator K100278, QUADROX-iR Adult K102627, QUADROX-iR Small Adult K102627, HLS modules K102627 and PLEGIOX Cardioplegia Heat Exchanger K090555. -3 6…
Maquet Cardiopulmonary, AG20091

Also cleared against K082117: 11 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 16, 2024Class IIZ-1077-2024Nonconforming Material/ComponentThe Emergency Priming Line, a component of the HLS Set, may have a compromised sterile barrier due to nonconformities at the bag seal. This issue may result in inflammation, sepsis, or infection.
Jan 16, 2024Class IIZ-1076-2024Nonconforming Material/ComponentThe Emergency Priming Line, a component of the HLS Set, may have a compromised sterile barrier due to nonconformities at the bag seal. This issue may result in inflammation, sepsis, or infection.
Feb 13, 2023Class IIZ-1188-2023Process controlFirm has initiated a removal of the product due to insufficient evidence of packaging sterility. Exposure to a non-sterile medical device may result in inflammation, infection, sepsis, or ischemia.
Jul 22, 2022Class IIZ-1764-2022Package design/selectionThe firm has expanded the recall for the HLS Set Advanced regarding a potential breach in the sterility barrier that may result in compromised product sterility (prior recall was initiated November 6, 2020).
Jul 22, 2022Class IIZ-1765-2022Package design/selectionThe firm has expanded the recall for the HLS Set Advanced regarding a potential breach in the sterility barrier that may result in compromised product sterility (prior recall was initiated November 6, 2020).
Jul 22, 2022Class IIZ-1767-2022Package design/selectionThe firm has expanded the recall for the HLS Set Advanced regarding a potential breach in the sterility barrier that may result in compromised product sterility (prior recall was initiated November 6, 2020).
Jul 22, 2022Class IIZ-1766-2022Package design/selectionThe firm has expanded the recall for the HLS Set Advanced regarding a potential breach in the sterility barrier that may result in compromised product sterility (prior recall was initiated November 6, 2020).
Nov 20, 2020Class IIZ-0633-2021Package design/selectionThe HLS Set Advanced (disposable for Cardiohelp) is being recalled due to breaches in the product's sterility barrier.
Nov 20, 2020Class IIZ-0632-2021Package design/selectionThe HLS Set Advanced (disposable for Cardiohelp) is being recalled due to breaches in the product's sterility barrier.
Jul 11, 2019Class IIZ-2149-2019Under Investigation by firmThe sets are configured with quick connectors that have been assembled in reverse on the arterial and venous lines, resulting in blue (venous) to red (arterial) and red (arterial) to blue (venous) connections. Due to this incorrect…
Aug 15, 2013Class IIZ-2262-2013Nonconforming Material/ComponentThe manufacturer has conducted a review of the results of product testing performed during the last twelve months and has identified specific lots of product which may not meet specifications for bond strength on the inlet and/or outlet…
Jun 12, 2012Class IIZ-0160-2013Nonconforming Material/ComponentIt has come to firm's attention that, in some rare cases, the blood outlet connector on some models of MAQUET Oxygenators may detach from the oxygenator. This event has occurred in about 0.01% (1:10,000) of units shipped.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K102464Quadrox-I Neonatal Microporous Membrane Oxygenator with Integrated Arterial Filter with Softline/Bioline…Maquet Cardiopulmonary, AG · 2011 · Direct predicate · ◆ in the 2011 ancestors bar of FIG. 12 Class I recalls

What does this lineage say?

  • The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 12 months on median.
  • 14 of the 48 ancestors have a recall of any class; 1 has a Class I recall.
  • 11 other devices also cite its predicate K082117.

How does its category compare?

All DTZ devices

DTZ Oxygenator, Cardiopulmonary Bypass: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · DTZ

2in 2025

2007: 42008: 32009: 92010: 22011: 42012: 92013: 92014: 52015: 92016: 32017: 22018: 32019: 52020: 52021: 52022: 22023: 52024: 32025: 22026 (partial year): 3
2007high 9 (2009) · low 2 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DTZ

124in 2024

2007: 55 days median2008: 88 days median2009: 210 days median2011: 160 days median2012: 90 days median2013: 28 days median2014: 28 days median2015: 134 days median2016: 62 days median2018: 72 days median2019: 90 days median2020: 93 days median2021: 336 days median2023: 145 days median2024: 124 days median2026 (partial year): 137 days median
2007high 336 (2021) · low 28 (2013)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DTZ

1in 2025

2007: 72008: 52010: 12011: 132012: 142014: 22016: 12018: 2, 2 Class I2019: 12020: 32021: 1, 1 Class I2022: 62025: 1
2007high 14 (2012) · low 0 (2009)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · DTZ

976in 2025

2007: 1342008: 1052009: 522010: 1192011: 1902012: 2152013: 3462014: 7642015: 6582016: 4432017: 3882018: 3202019: 4892020: 4422021: 5952022: 5592023: 7382024: 5352025: 976
2007high 976 (2025) · low 52 (2009)2025

MAUDE reports naming product code DTZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074557134
20083885105
20099210052
20102—1119
2011416013190
201299014215
20139280346
20145282764
201591340658
20163621443
20172—0388
20183722 (2)320
20195901489
20205933442
202153361 (1)595
20222—6559
202351450738
202431240535
20252—1976
202631370—

What is it indicated for?

The membrane oxygenator Quadrox-i Adult is intended for the use in extracorporeal circulation during cardiopulmonary bypass in cardiac surgery. Within the specified flow rate range, the device oxygenates the blood, eliminates carbon dioxide and regulates blood temperature. The Quadrox-i Adult (HMO 71000) version with integrated arterial filter also filters out air bubbles and particles larger than 40 pm. The device's utilization period is limited to six…

Read the full statement (708 words)

The membrane oxygenator Quadrox-i Adult is intended for the use in extracorporeal circulation during cardiopulmonary bypass in cardiac surgery. Within the specified flow rate range, the device oxygenates the blood, eliminates carbon dioxide and regulates blood temperature. The Quadrox-i Adult (HMO 71000) version with integrated arterial filter also filters out air bubbles and particles larger than 40 pm. The device's utilization period is limited to six hours.

Responsibility for deciding whether to use an oxygenator rests solely with the attending physician

The membrane oxygenator QUADROX-i Small Adult is intended for the use in extracorporeal circulation during cardiopulmonary bypass in cardiac surgery. The blood flow rate is defined from 0.5 - 5 Llmin. Within the specified flow rate range, the device oxygenates the blood, eliminates carbon dioxide and regulates blood temperature. The OUADROX-i Small Adult (HMO 51000) version with integrated arterial filter also filters out air bubbles and particles larger than 40 pm. The device's utilization period is limited to six hours.

Responsibility for deciding whether to use an oxygenator rests solely with the attending physician.

The membrane oxygenator QUADROX-i Pediatric is intended for use in extracorporeal circulation during cardiopulmonary bypass in cardiac surgery. It is designed for a blood flow rate of 0.2 - 2.8 I/min and is intended for the treatment of pediatric patients. Within the specified flow rate range, the device oxygenates the blood, removes carbon dioxide and regulates the blood temperature. The QUADROX-i Pediatric (HMO 31000) model with integrated arterial filter also filters air bubbles and particles larger than 33 pm. The utilization period of this device is restricted to six hours. Responsibility for deciding whether to use an oxygenator rests solely with the attending physician.

The membrane oxygenator QUADROX-i Neonatal is intended for use in extracorporeal circulation during cardiopulmonary bypass in cardiac surgery. It is designed for a blood flow rate of 0.2 - 1.5 I/min and is intended for the treatment of pediatric patients. Within the specified flow rate range, the device oxygenates the blood, removes carbon dioxide and regulates the blood temperature. The QUADROX-i Neonatal (HMO 11000) model with integrated arterial filter also filters air bubbles and particles larger than 33 pm. The utilization period of this device is restricted to six hours. Responsibility for deciding whether to use an oxygenator rests solely with the attending physician.

The QUADROX-iD Adult Diffusion Membrane Oxygenator is intended for use in an extracorporeal circulation during cardiopulmonary bypass in cardiac surgery. Within the specified flow rate range, the device oxygenates the blood, removes carbon dioxide from the blood and regulates the blood temperature. The application duration is limited to 6 hours. Responsibility for deciding whether to use an oxygenator rests solely with the attending physician.

The Diffusion Membrane Oxygenator QUADROX-iD Pediatric is intended for use in an extracorporeal circulation during cardiopulmonary bypass in cardiac surgery. The oxygenator is designed for a blood flow rate of 0.2 - 2.8 1/mm and is intended for the treatment of pediatric patients. Within the specified flow rate range, the device oxygenates the blood, removes carbon dioxide and regulates the blood temperature. The utilization period for this device is restricted to six hours. Responsibility for deciding whether to use an oxygenator rests solely with the attending physician.

The CARDIOHELP System is a blood oxygenation and carbon dioxide removal system used to pump blood through the extracorporeal bypass circuit for circulatory and/or pulmonary support during procedures requiring cardiopulmonary bypass (for periods up to six hours). It is also intended to provide circulatory and/or pulmonary support during procedures not requiring cardiopulmonary bypass (for periods up to six hours).

The CARDIOHELP System in configuration with the HLS/HIT Set Advanced is intended to be used within the hospital environment and outside the hospital environment (for periods up to six hours), e.g. for intra- and inter-hospital transport.

The CARDIOHELP System in configuration with the QUADROX-iR is intended to be used in extracorporeal circulation during cardiopulmonary bypass in cardiac surgery (for periods for up to six hours).

The PLEGIOX Heat Exchanger is used to set and maintain the temperature (for given flow rates and within the given temperature range) of blood cardiopiegic and crystalloid cardioplegic solutions during extracorporeal circulation. The product is designed for single use only, for an application period of no longer than 6 hours.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K112360: Quadrox-I Microporporous Membrane Oxgenator Series and Qudrox-ID Diffusion Membrane Oxygenators Series.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K112360

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026