510(k) Report

510(k) · Cleared

Recalled · Class II · 2018

Radrex-I, SW V4.00 Model Drad-3000E

K122842510(k) SpecialCleared Oct 9, 201222-day reviewClass II21 CFR 892.1680Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Toshiba America Medical Systems, In.C · MQB Solid State X-Ray Imager (Flat Panel/Digital Imager)

Cleared on Oct 9, 2012 as substantially equivalent to K082494 (Toshiba America Medical Systems, In.C, 2008) and 1 other predicate after a 22-day review. Its family tree reaches back 5 generations to 1994. It has been recalled 3 times.

Decided
Oct 9, 2012
Review
22 days
Class
Class II
Product code
MQB
Recalls
3
Predicates
2

Its longest line of descent runs back 5 generations to K931071 (1994). 7 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 5 generations backK931071 Philips ThoravisionPhilips Medical Systems, Inc. · 1994 · Recalled
  2. 4 generations backK982795 Philips Bucky VisionPhilips Medical Systems, Inc. · 1998 · Recalled
  3. 3 generations backK073165 Drad-3000E, Radrex-IToshiba America Medical Systems, In.C · 2007 · Recalled
  4. 2 generations backK082494 DRAD3000E/Radrex-IToshiba America Medical Systems, In.C · 2008
  5. 1 generation backK083503 DRAD30003/Radrex-IToshiba America Medical Systems, In.C · 2009 · Recalled
  6. This deviceK122842 Radrex-I, SW V4.00 Model Drad-3000EToshiba America Medical Systems, In.C · 2012
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K931071Philips ThoravisionPhilips Medical Systems, Inc.19941
−4K982795Philips Bucky VisionPhilips Medical Systems, Inc.199817
−3K073165Drad-3000E, Radrex-IToshiba America Medical Systems, In.C20071
−2K082494DRAD3000E/Radrex-IToshiba America Medical Systems, In.C2008—
−1K083503DRAD30003/Radrex-IToshiba America Medical Systems, In.C20091
0 (this device)K122842Radrex-I, SW V4.00 Model Drad-3000EToshiba America Medical Systems, In.C2012—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199710
FIG. 1 — Lineage of K122842, 1994–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQB device

  1. #1 K201528 Yushan X-Ray Flat Panel Detector with DROCscore 21.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K082494DRAD3000E/Radrex-I
Summary page 1
…ger) 10. PERFORMANCE STANDARD: 21 CFR Subchapter J, Federal Diagnostic X-ray Equipment Standard 11. PREDICATE DEVICE: Toshiba RADREX-i (DRAD-3000E), v2.31: K082494 Toshiba RADREX-i, (DRAD-3000E), v3.0: K083503 12. REASON FOR SUBMISSION: Modification of a cleared device…
Toshiba America Medical Systems, In.C2008—
*K083503DRAD30003/Radrex-I
Summary page 1
…pter J, Federal Diagnostic X-ray Equipment Standard 11. PREDICATE DEVICE: Toshiba RADREX-i (DRAD-3000E), v2.31: K082494 Toshiba RADREX-i, (DRAD-3000E), v3.0: K083503 12. REASON FOR SUBMISSION: Modification of a cleared device…
Toshiba America Medical Systems, In.C20091

Also cleared against K082494: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 16, 2018Class IIZ-1958-2019Software designsoftware malfunction; It was found when a user performs radiography using the wireless flat panel detector (FPD), a message window displays on the monitor stating image transmission was not completed and there was no image available. It…
Apr 18, 2018Class IIZ-2964-2018Software designIt was found when an operator performs a radiography using the wireless flat panel detector (FPD), a message window was displayed on the monitor stating image transmission was not completed and there was no image. It also showed the OK…
Mar 23, 2017Class IIZ-3111-2017Software designIt was discovered during a procedure that when the operator made an exposure on the wireless x-ray detector and the image data was sent to the digital radiography system, and error message was displayed " System Error (2063)" which…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 2 companies; a new generation was cleared every 3.7 years on median.
  • 5 of the 7 ancestors have a recall of any class.
  • 1 other device also cites its predicate K082494.

How does its category compare?

All MQB devices

MQB Solid State X-Ray Imager (Flat Panel/Digital Imager): FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · MQB

8in 2025

2007: 132008: 82009: 152010: 112011: 242012: 222013: 212014: 322015: 212016: 222017: 312018: 162019: 222020: 192021: 212022: 312023: 102024: 82025: 82026 (partial year): 3
2007high 32 (2014) · low 8 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQB

127in 2025

2007: 22 days median2008: 15 days median2009: 57 days median2010: 116 days median2011: 102 days median2012: 80 days median2013: 105 days median2014: 102 days median2015: 81 days median2016: 92 days median2017: 30 days median2018: 30 days median2019: 30 days median2020: 28 days median2021: 48 days median2022: 48 days median2023: 30 days median2024: 187 days median2025: 127 days median2026 (partial year): 245 days median
2007high 245 (2026) · low 15 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQB

1in 2025

2007: 152008: 362009: 192010: 142011: 102012: 82013: 62017: 12018: 42019: 12020: 42021: 12025: 12026 (partial year): 1
2007high 36 (2008) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQB

141in 2025

2007: 252008: 302009: 342010: 392011: 1012012: 2672013: 1592014: 292015: 212016: 262017: 202018: 842019: 452020: 92021: 262022: 132023: 512024: 912025: 141
2007high 267 (2012) · low 9 (2020)2025

MAUDE reports naming product code MQB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200713221525
20088153630
200915571934
2010111161439
20112410210101
201222808267
2013211056159
201432102029
20152181021
20162292026
20173130120
20181630484
20192230145
2020192849
20212148126
20223148013
20231030051
20248187091
202581271141
202632451—

What is it indicated for?

This device is indicated as a general radiography device. It is capable of providing digital images of the head, neck, spine, chest, abdomen, and limbs by converting x-rays to digital images. Excluded indications include mammography, fluoroscopy and angiography studies.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K122842: Radrex-I, SW V4.00 Model Drad-3000E.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K122842

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026