Philips Bucky Vision

K982795510(k) TraditionalCleared Nov 24, 1998106-day reviewClass II21 CFR 892.1680Recalls 17

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Medical Systems, Inc. · MQB Solid State X-Ray Imager (Flat Panel/Digital Imager)

Cleared on Nov 24, 1998 as substantially equivalent to K945278 (Philips Medical Systems North America, Inc., 1994) and 2 other predicates after a 106-day review. Its family tree reaches back 1 generation to 1994. 141 later devices descend from it. It has been recalled 17 times.

Decided
Nov 24, 1998
Review
106 days
Class
Class II
Product code
MQB
Recalls
17
Predicates
3

Its longest line of descent runs back 1 generation to K931071 (1994). 3 ancestors in all. 141 later devices descend from it, 11 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1997: 1 other ancestor1994: 1 other ancestor2007: 3 descendants cleared2009: 6 descendants cleared2019: 9 descendants cleared2013: 11 descendants cleared2008: 2 descendants cleared2014: 12 descendants cleared2003: 1 descendant cleared2011: 10 descendants cleared1999: 1 descendant cleared2012: 5 descendants cleared2010: 6 descendants cleared2017: 12 descendants cleared2020: 7 descendants cleared2006: 1 descendant cleared2016: 10 descendants cleared2015: 5 descendants cleared2021: 12 descendants cleared2018: 5 descendants cleared2023: 5 descendants cleared2026: 5 descendants cleared2024: 3 descendants cleared2022: 5 descendants cleared2025: 5 descendants clearedK931071 · Philips Thoravision · Philips Medical Systems, Inc. · 1994 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors 1 generation forward: 11 descendants2 generations forward: 20 descendants3 generations forward: 29 descendants4 generations forward: 31 descendants5 generations forward: 21 descendants6 generations forward: 12 descendants7 generations forward: 8 descendants8 generations forward: 5 descendants9 generations forward: 2 descendants10 generations forward: 2 descendants K931071 · Philips Thoravision · Philips Medical Systems, Inc. · 1994 · recalled0+5+10
  1. Root · 1 generation backK931071 Philips ThoravisionPhilips Medical Systems, Inc. · 1994 · Recalled
  2. This deviceK982795 Philips Bucky VisionPhilips Medical Systems, Inc. · 1998
  3. Descendant · cites it directly · 103 of its ownK992794 Stingray DR, Model 1Infimed, Inc. · 1999
  4. Descendant · cites it directly · 78 of its ownK024147 Paxscan 4030 Medical Digital Imaging SystemVarian Medical Systems, Inc. · 2003
  5. Descendant · cites it directly · 41 of its ownK090625 Wireless Portable Detector FD-W17Philips Medical Systems North America Co. · 2009 · Recalled
  6. Descendant · 2 generations on · 34 of its ownK092669 DX-D Imaging PackageAgfa Healthcare N.V. · 2009 · Recalled
  7. Descendant · 2 generations on · 30 of its ownK120020 Vivix-SVieworks Co., Ltd. · 2012

Showing 5 of 141 descendants. See all descendants

Descendants cleared per year

1999: 12003: 12006: 12007: 32008: 22009: 62010: 62011: 102012: 52013: 112014: 122015: 52016: 102017: 122018: 52019: 92020: 72021: 122022: 52023: 52024: 32025: 52026: 5
1999high 12 (2014) · low 0 (2000)2026

Most influential descendants

Showing 5 of 141 · See all
  • K992794Stingray DR, Model 1Infimed, Inc. · 1999 · cites it directly103descendants
  • K024147Paxscan 4030 Medical Digital Imaging SystemVarian Medical Systems, Inc. · 2003 · cites it directly78descendants
  • K090625Wireless Portable Detector FD-W17Philips Medical Systems North America Co. · 2009 · cites it directly41descendants
  • K092669DX-D Imaging PackageAgfa Healthcare N.V. · 2009 · 2 generations on34descendants
  • K120020Vivix-SVieworks Co., Ltd. · 2012 · 2 generations on30descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K931071Philips ThoravisionPhilips Medical Systems, Inc.19941
0 (this device)K982795Philips Bucky VisionPhilips Medical Systems, Inc.1998—
+1K992794Stingray DR, Model 1Infimed, Inc.1999—
+1K024147Paxscan 4030 Medical Digital Imaging SystemVarian Medical Systems, Inc.2003—
+1K090625Wireless Portable Detector FD-W17Philips Medical Systems North America Co.200928
+2K092669DX-D Imaging PackageAgfa Healthcare N.V.20091
+2K120020Vivix-SVieworks Co., Ltd.2012—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199910
200310
200610
200730
200820
200960
201060
2011100
201250
2013110
2014120
201550
2016100
2017120
201850
201990
202070
2021120
202250
202350
202430
202550
202650
FIG. 1 — Lineage of K982795, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQB device

  1. #1 K201528 Yushan X-Ray Flat Panel Detector with DROCscore 21.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K945278Philips Bucky Diagnost Family
Our OCR of the scanned summary read K945287, FDA’s number for Inhealth Blom-Singer Indwelling Valved Insert Accessory… (Helix Medical, Inc.). Corrected to the number with two digits swapped whose FDA name carries the summary’s words for the device, “Philips bucky Diagnost System with Radiographic Screen Film Systems”.
Philips Medical Systems North America, Inc.199410
*K973206Sterling Diagnostic Imaging Direct Radiography
Summary page 2
…hilips bucky Diagnost System 510(k) Number : K945287, with Radiographic Screen Film Systems, the Sterling Diagnostic Imaging Direct Radiography™ device: 510(k) Number : K973206 and the Philips Thoravision 510(k) Number : K931071. Therefore the Philips BuckyVision system complies to the same or equivalent…
Sterling Diagnostic Imaging, Inc.1997—
*K931071Philips Thoravision
Summary page 2
…, with Radiographic Screen Film Systems, the Sterling Diagnostic Imaging Direct Radiography™ device: 510(k) Number : K973206 and the Philips Thoravision 510(k) Number : K931071. Therefore the Philips BuckyVision system complies to the same or equivalent standards and has the same intended use as the pred…
Philips Medical Systems, Inc.19941

Also cleared against K945278: 1 other device →

What descends from it? (141)

See all 141

11 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K992794Stingray DR, Model 1Infimed, Inc.1999103
K024147Paxscan 4030 Medical Digital Imaging SystemVarian Medical Systems, Inc.200378
K090625Wireless Portable Detector FD-W17Philips Medical Systems North America Co.200941
K063781Philips XD-S Direct Radiography Workstation/PackagePhilips Medical Systems North America Co.200716
K182973DigitalDiagnost C90Philips Medical Systems Dmc GmbH20193
K141381DuradiagnostPhilips Healthcare (Suzhou) Co., Ltd.20143
K073165Drad-3000E, Radrex-IToshiba America Medical Systems, In.C20073
K082494DRAD3000E/Radrex-IToshiba America Medical Systems, In.C20082
K131483Philips Pixium 4343RCPhilips Medical Systems Dmc GmbH20131
K083503DRAD30003/Radrex-IToshiba America Medical Systems, In.C20091

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 17, 2014Class IIZ-1503-2014Process controlThe footboard of Patient support for stitching can be fixed in upper position. When the fix clamp (hook) is not correctly adjusted into its correct position, the footboard is not securely held.
Aug 8, 2013Class IIZ-2059-2013Software designThe mirror icon on the bottom of each image could be misinterpreted as a RIGHT lead marker for side indication if the image is mirrored within a PACS system.
Jan 16, 2013Class IIZ-1448-2013Radiation Control for Health and Safety ActInstallation Acceptance Test Document (IATD) non compliant with regulations. Records shows table height measurements out of specification with the consequence of potential system mis-alignment.
Jan 16, 2013Class IIZ-1447-2013Radiation Control for Health and Safety ActInstallation Acceptance Test Document (IATD) non compliant with regulations IATDs (Installation Acceptance Test could not be located or different templates have been used
Oct 30, 2012Class IIZ-0475-2013Software designWith Digital Diagnost R2.0.2 a mirrored "R in a circle" is burnt into the image (if mirrored) in the lower right corner of the image. When such an image is mirrored back inside the PACS system, an unmirrored "R in a circle" appears in the…
Oct 30, 2012Class IIZ-0900-2013Software designWhen the operator for a wall stand view selects an "image rotation" different from default, or such image rotation is preset in the examination database, then the resulting image may be rotated in the wrong direction. When the operator…
Oct 25, 2012Class IIZ-0884-2013Software designWhen the operator for a wall stand view selects an "image rotation" different from default, or such image rotation is preset in the examination database, then the resulting image may be rotated in the wrong direction. When the operator…
Sep 12, 2012Class IIZ-2494-2012Device DesignHook does not securely hold the footplate in vertical position, causing the footplate to disengage and may fall on patient or operator
Sep 6, 2012Class IIZ-2465-2012Device DesignThe Wireless Portable Detector (WPD) is not fixed securely inside the Mobile Detector Holder and may fall down
Aug 14, 2012Class IIZ-2384-2012Device DesignCreepage Distance between the two primary phases in the GEO Transformer is 4.5 mm.does not meet (IEC) International standard of 5.5 mm.
May 22, 2012Class IIZ-1818-2012Software change controlWith Digital Diagnost (DIDI) R 2.0.2 a mirrored "R in a circle" is burnt into the image (if mirrored) in the lower right corner of the image. When such an image is mirrored back inside the PACS system, an unmirrored "R in a circle"…
Apr 3, 2012Not classifiedZ-1464-2012Labeling designPotential misdiagnosis due to improperly automatically stitched images, improper image ruler handling.
Nov 1, 2011Not classifiedZ-0313-2012Process controlMissing a small, metal protective cover on the bottom side of the control handle for the ceiling suspension. exposes printed circuit
Sep 9, 2010Not classifiedZ-0022-2011Equipment maintenancePotential of broken strands in the main steel cable supporting the accessory holder used with BuckyDiagnost and DigitalDiagnost X-ray systems.
Jan 21, 2010Not classifiedZ-0847-2010Radiation Control for Health and Safety ActDevice failed to display appropriate labels indicating Radiation Symbol along with the required wording.
Dec 13, 2007Not classifiedZ-2422-2010Software designWhen using DICOM print functionality, the printed images may contain data for the wrong patient.
Jul 23, 2007Not classifiedZ-0908-2007OtherUnits do not comply with the requirement to provide automatic beam limitation within +/- 3 degrees of horizontal, vertical, and perpendicular to the plane of the image receptor during radiographic procedures.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 2 of the 3 ancestors have a recall of any class.
  • Of its descendants, K992794 (Infimed, Inc., 1999) has gone furthest, with 103 descendants of its own.
  • 1 other device also cites its predicate K945278.

How does its category compare?

All MQB devices

MQB Solid State X-Ray Imager (Flat Panel/Digital Imager): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MQB

8in 2025

2007: 132008: 82009: 152010: 112011: 242012: 222013: 212014: 322015: 212016: 222017: 312018: 162019: 222020: 192021: 212022: 312023: 102024: 82025: 82026 (partial year): 3
2007high 32 (2014) · low 8 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQB

127in 2025

2007: 22 days median2008: 15 days median2009: 57 days median2010: 116 days median2011: 102 days median2012: 80 days median2013: 105 days median2014: 102 days median2015: 81 days median2016: 92 days median2017: 30 days median2018: 30 days median2019: 30 days median2020: 28 days median2021: 48 days median2022: 48 days median2023: 30 days median2024: 187 days median2025: 127 days median2026 (partial year): 245 days median
2007high 245 (2026) · low 15 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQB

1in 2025

2007: 152008: 362009: 192010: 142011: 102012: 82013: 62017: 12018: 42019: 12020: 42021: 12025: 12026 (partial year): 1
2007high 36 (2008) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQB

141in 2025

2007: 252008: 302009: 342010: 392011: 1012012: 2672013: 1592014: 292015: 212016: 262017: 202018: 842019: 452020: 92021: 262022: 132023: 512024: 912025: 141
2007high 267 (2012) · low 9 (2020)2025

MAUDE reports naming product code MQB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200713221525
20088153630
200915571934
2010111161439
20112410210101
201222808267
2013211056159
201432102029
20152181021
20162292026
20173130120
20181630484
20192230145
2020192849
20212148126
20223148013
20231030051
20248187091
202581271141
202632451—

What is it indicated for?

The Philips BuckyVision is intended for use in general radiographic examinations and applications wherever conventional screen-film systems may be used (excluding fluoroscopy, angiography, and mammography).

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K982795: Philips Bucky Vision.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K982795

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026