510(k) Report

510(k) · Cleared

Recalled · 2009

Drad-3000E, Radrex-I

K073165510(k) TraditionalCleared Nov 16, 20077-day reviewClass II21 CFR 892.1680Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Toshiba America Medical Systems, In.C · MQB Solid State X-Ray Imager (Flat Panel/Digital Imager)

Cleared on Nov 16, 2007 as substantially equivalent to K982795 (Philips Medical Systems, Inc., 1998) after a 7-day review. Its family tree reaches back 2 generations to 1994. 3 later devices descend from it. It has been recalled once.

Decided
Nov 16, 2007
Review
7 days
Class
Class II
Product code
MQB
Recalls
1
Predicates
1

Its longest line of descent runs back 2 generations to K931071 (1994). 4 ancestors in all. 3 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1997: 1 other ancestor1994: 1 other ancestor2008: 1 descendant cleared2012: 1 descendant cleared2009: 1 descendant clearedK931071 · Philips Thoravision · Philips Medical Systems, Inc. · 1994 · recalledK982795 · Philips Bucky Vision · Philips Medical Systems, Inc. · 1998 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 2 other ancestors 1 generation forward: 1 descendant2 generations forward: 2 descendants K982795 · Philips Bucky Vision · Philips Medical Systems, Inc. · 1998 · recalledK931071 · Philips Thoravision · Philips Medical Systems, Inc. · 1994 · recalled0
  1. Root · 2 generations backK931071 Philips ThoravisionPhilips Medical Systems, Inc. · 1994 · Recalled
  2. 1 generation backK982795 Philips Bucky VisionPhilips Medical Systems, Inc. · 1998 · Recalled
  3. This deviceK073165 Drad-3000E, Radrex-IToshiba America Medical Systems, In.C · 2007
  4. Descendant · cites it directly · 2 of its ownK082494 DRAD3000E/Radrex-IToshiba America Medical Systems, In.C · 2008
  5. Descendant · 2 generations on · 1 of its ownK083503 DRAD30003/Radrex-IToshiba America Medical Systems, In.C · 2009 · Recalled
  6. Descendant · 2 generations on · 0 of its ownK122842 Radrex-I, SW V4.00 Model Drad-3000EToshiba America Medical Systems, In.C · 2012 · Recalled

Most influential descendants

Showing 3 of 3 · See all
  • K082494DRAD3000E/Radrex-IToshiba America Medical Systems, In.C · 2008 · cites it directly2descendants
  • K083503DRAD30003/Radrex-IToshiba America Medical Systems, In.C · 2009 · 2 generations on1descendant
  • K122842Radrex-I, SW V4.00 Model Drad-3000EToshiba America Medical Systems, In.C · 2012 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K931071Philips ThoravisionPhilips Medical Systems, Inc.19941
−1K982795Philips Bucky VisionPhilips Medical Systems, Inc.199817
0 (this device)K073165Drad-3000E, Radrex-IToshiba America Medical Systems, In.C2007—
+1K082494DRAD3000E/Radrex-IToshiba America Medical Systems, In.C2008—
+2K083503DRAD30003/Radrex-IToshiba America Medical Systems, In.C20091
+2K122842Radrex-I, SW V4.00 Model Drad-3000EToshiba America Medical Systems, In.C20123

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200810
200910
201210
FIG. 1 — Lineage of K073165, 1994–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQB device

  1. #1 K201528 Yushan X-Ray Flat Panel Detector with DROCscore 21.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K982795Philips Bucky Vision
Summary page 1
…f (per 21 CFR 892.1650) 21 CFR Subchapter J, Federal Diagnostic X-ray Equipment Standard Philips Medical Systems Bucky Vision (Digital Diagnost) 510(k) Contro! Number: K982795 New device The RADREX-I is a general purpose x-ray system that employs Solid State Imager(s), SSXI, which converts x-rays direc…
Philips Medical Systems, Inc.199817

Also cleared against K982795: 10 other devices →

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K082494DRAD3000E/Radrex-IToshiba America Medical Systems, In.C20082

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 22, 2009Not classifiedZ-1177-2010Component design/selectionToshiba America Medical Systems Inc (TAMS) has initiated a field correction on the DRAD-3000E; Radrex-I, Electrostatic x-ray imaging system due to a software bug that results in a loss of image.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 2 companies; a new generation was cleared every 9.0 years on median.
  • 3 of the 4 ancestors have a recall of any class.
  • Of its descendants, K082494 (Toshiba America Medical Systems, In.C, 2008) has gone furthest, with 2 descendants of its own.
  • 10 other devices also cite its predicate K982795.

How does its category compare?

All MQB devices

MQB Solid State X-Ray Imager (Flat Panel/Digital Imager): FDA decisions, review times, recalls and adverse event reports over 20 years. 2007, this device’s year, is highlighted.

FDA decisions per year · MQB

8in 2025

2007: 132008: 82009: 152010: 112011: 242012: 222013: 212014: 322015: 212016: 222017: 312018: 162019: 222020: 192021: 212022: 312023: 102024: 82025: 82026 (partial year): 3
2007high 32 (2014) · low 8 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQB

127in 2025

2007: 22 days median2008: 15 days median2009: 57 days median2010: 116 days median2011: 102 days median2012: 80 days median2013: 105 days median2014: 102 days median2015: 81 days median2016: 92 days median2017: 30 days median2018: 30 days median2019: 30 days median2020: 28 days median2021: 48 days median2022: 48 days median2023: 30 days median2024: 187 days median2025: 127 days median2026 (partial year): 245 days median
2007high 245 (2026) · low 15 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQB

1in 2025

2007: 152008: 362009: 192010: 142011: 102012: 82013: 62017: 12018: 42019: 12020: 42021: 12025: 12026 (partial year): 1
2007high 36 (2008) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQB

141in 2025

2007: 252008: 302009: 342010: 392011: 1012012: 2672013: 1592014: 292015: 212016: 262017: 202018: 842019: 452020: 92021: 262022: 132023: 512024: 912025: 141
2007high 267 (2012) · low 9 (2020)2025

MAUDE reports naming product code MQB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200713221525
20088153630
200915571934
2010111161439
20112410210101
201222808267
2013211056159
201432102029
20152181021
20162292026
20173130120
20181630484
20192230145
2020192849
20212148126
20223148013
20231030051
20248187091
202581271141
202632451—

What is it indicated for?

This device Is indicated as a general radiography device. It is capable of providing digital images of the head, neck, spine, chest abdomen and limbs by converting x-rays to digital images. Excluded indications include mammography, fluoroscopy and angiography studies.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K073165: Drad-3000E, Radrex-I.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K073165

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026