510(k) Report

510(k) · Cleared

Cleared

Accumesh Deployment System

K130782510(k) SpecialCleared Apr 5, 201315-day reviewClass II21 CFR 878.3300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Covidien, LLC · ORQ Mesh, Surgical, Deployer

Cleared on Apr 5, 2013 as substantially equivalent to K101218 (Polytouch Medical, Ltd., 2010) and 2 other predicates after a 15-day review. Its family tree reaches back 4 generations to 2010.

Decided
Apr 5, 2013
Review
15 days
Class
Class II
Product code
ORQ
Recalls
None
Predicates
3

Its longest line of descent runs back 4 generations to K101218 (2010). No later device cites it as a predicate yet.

  1. Root · 4 generations backK101218 PatchassistPolytouch Medical, Ltd. · 2010
  2. 3 generations backK103269 Patchassist LargePolytouch Medical, Ltd. · 2010
  3. 2 generations backK121139 Accumesh Deployment SystemCovidien, LLC · 2012
  4. 1 generation backK123066 Accumesh Deployment SystemCovidien, LLC · 2012
  5. This deviceK130782 Accumesh Deployment SystemCovidien, LLC · 2013
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K101218PatchassistPolytouch Medical, Ltd.2010—
−3K103269Patchassist LargePolytouch Medical, Ltd.2010—
−2K121139Accumesh Deployment SystemCovidien, LLC2012—
−1K123066Accumesh Deployment SystemCovidien, LLC2012—
0 (this device)K130782Accumesh Deployment SystemCovidien, LLC2013—
FIG. 1 — Lineage of K130782, 2010–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ORQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ORQ device

  1. #1 K250395 BioBrace ® RC Delivery Systemscore 12.7 · 13 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K101218Patchassist
Summary page 1
…o which equivalence is claimed: o Accumesh Positioning System (510k cleared as the PatchAssist device - K101218 o Accumesh Positioning System PatchAssist Large (510k cleared a…
Polytouch Medical, Ltd.2010—
*K103269Patchassist Large
Summary page 2
…ame, itself, has not changed and is previously cleared in the AccuMesh (PatchAssist) device (K101218, K103269, and K123066) 510(k)s. Accumesh is intended to be used to facilitate the…
Polytouch Medical, Ltd.2010—
*K123066Accumesh Deployment System
Summary page 1
…em PatchAssist Large (510k cleared as the PatchAssist device - KI103269 o AccuMesh Positioning System - K123066 14 Covidien…
Covidien, LLC2012—

Also cleared against K101218: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 3 years and passes through 2 companies; a new generation was cleared every 6 months on median.
  • None of the 4 ancestors has a recall.
  • 3 other devices also cite its predicate K101218.

How does its category compare?

All ORQ devices

ORQ Mesh, Surgical, Deployer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · ORQ

1in 2025

2010: 22012: 22013: 12025: 1
2007high 2 (2010) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ORQ

Too few ORQ 510(k)s in any year since 2007 to give a median.

Recalls per year · ORQ

No recall names ORQ since 2007.

Adverse event reports per year · ORQ

11in 2025

2014: 12015: 12016: 102017: 102019: 42020: 12021: 52022: 22023: 12025: 11
2007high 11 (2025) · low 0 (2007)2025

MAUDE reports naming product code ORQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20102—00
20110—00
20122—00
20131—00
20140—01
20150—01
20160—010
20170—010
20180—00
20190—04
20200—01
20210—05
20220—02
20230—01
20240—00
20251—011
20260—0—

What is it indicated for?

The AccuMesh Positioning System is intended to be used to facilitate the delivery of soft tissue prosthetics during the laparoscopic repair of soft tissue defects (e.g. hernia repair).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K130782: Accumesh Deployment System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K130782

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026