510(k) Report

510(k) · Cleared

Recalled · Class II · 2022

Advia Chemistry Fructosamine Assay, Advia Chemistry Fructosamine Calibrator

K131307510(k) TraditionalCleared Jan 24, 2014262-day reviewClass II21 CFR 864.7470Recalls 5

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Healthcare Diagnostics, Inc. · LCP Assay, Glycosylated Hemoglobin

Cleared on Jan 24, 2014 as substantially equivalent to K042193 (Diazyme Laboratories, 2004) and 1 other predicate after a 262-day review. Its family tree reaches back 2 generations to 2003. It has been recalled 5 times.

Decided
Jan 24, 2014
Review
262 days
Class
Class II
Product code
LCP
Recalls
5
Predicates
2

Its longest line of descent runs back 2 generations to K023763 (2003). No later device cites it as a predicate yet.

  1. Root · 2 generations backK023763 Randox Fructosamine, Fructosamine Calibrator, Fructosamine ControlsRandox Laboratories, Ltd. · 2003 · Recalled
  2. 1 generation backK042193 Diazyme Glycated Serum Protein Enzymatic Assay KitDiazyme Laboratories · 2004
  3. This deviceK131307 Advia Chemistry Fructosamine Assay, Advia Chemistry Fructosamine…Siemens Healthcare Diagnostics, Inc. · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K023763Randox Fructosamine, Fructosamine Calibrator, Fructosamine ControlsRandox Laboratories, Ltd.20033
−1K042193Diazyme Glycated Serum Protein Enzymatic Assay KitDiazyme Laboratories2004—
0 (this device)K131307Advia Chemistry Fructosamine Assay, Advia Chemistry Fructosamine CalibratorSiemens Healthcare Diagnostics, Inc.2014—
FIG. 1 — Lineage of K131307, 2003–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LCP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LCP device

  1. #1 K221326 Nova Allegro HbA1c Assay, Nova Allegro Analyzerscore 9.6 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K042193Diazyme Glycated Serum Protein Enzymatic Assay Kit
Summary page 2
…Diazyme Glycated Serum Protein Assay 2. Common Name: Diazyme Glycated Serum Protein Assay 3. 510() Number k042 193 4. Manufacturer: Diazyme Lbratories Calibrators: 1. Device Name: Randox Fructosamine…
Diazyme Laboratories2004—
*K023763Randox Fructosamine, Fructosamine Calibrator, Fructosamine Controls
Summary page 2
…brators: 1. Device Name: Randox Fructosamine Calibrator 2. Common Name: Randox Fructosamine Calibrator 3. 510() Number k023 763 4. Manufacturer: Randox Laboratories, Ltd. G. Intended Use and Indication for Use: ADVIA Chemistry Fruc…
Randox Laboratories, Ltd.20033

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 9, 2022Class IIZ-0930-2022Device DesignSiemens Healthcare Diagnostics Inc. has confirmed the potential for reagent carryover impacting quality control (QC), patient samples, and calibrator results.
Sep 22, 2020Class IIZ-0101-2021Device DesignFructosamine QC and patient samples may exhibit a 60 umol/L positive bias across the measuring range compared to predicate assay reference leading to a potential adjustment of hyperglycemic therapy. Positively biased fructosamine results…
Sep 22, 2020Class IIZ-0102-2021Device DesignFructosamine QC and patient samples may exhibit a 60 umol/L positive bias across the measuring range compared to predicate assay reference leading to a potential adjustment of hyperglycemic therapy. Positively biased fructosamine results…
May 4, 2020Class IIZ-2281-2020Device DesignThe presence of N-acetyl-p-benzoquinone imine (NAPQI), a metabolite of acetaminophen, may cause interference in certain chemistry assays when testing patient samples.
May 4, 2020Class IIZ-2280-2020Device DesignThe presence of N-acetyl-p-benzoquinone imine (NAPQI), a metabolite of acetaminophen, may cause interference in certain chemistry assays when testing patient samples.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 3 companies; a new generation was cleared every 9.2 years on median.
  • 1 of the 2 ancestors has a recall of any class.

How does its category compare?

All LCP devices

LCP Assay, Glycosylated Hemoglobin: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · LCP

1in 2024

2007: 72008: 52009: 62010: 22011: 102012: 92013: 22014: 82015: 32016: 22017: 52018: 22019: 42020: 12023: 22024: 1
2007high 10 (2011) · low 0 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LCP

269in 2019

2007: 133 days median2008: 206 days median2009: 158 days median2011: 176 days median2012: 143 days median2014: 127 days median2015: 239 days median2017: 218 days median2019: 269 days median
2007high 269 (2019) · low 127 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LCP

1in 2025

2007: 12008: 32009: 62010: 52011: 512013: 42014: 22015: 22016: 62017: 12018: 12022: 12024: 12025: 1
2007high 51 (2011) · low 0 (2012)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LCP

22in 2025

2007: 52008: 112009: 152010: 42011: 272012: 512013: 1932014: 1822015: 642016: 292017: 1492018: 1,9112019: 1142020: 132021: 72022: 82023: 272024: 392025: 22
2007high 1,911 (2018) · low 4 (2010)2025

MAUDE reports naming product code LCP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007713315
20085206311
20096158615
20102—54
2011101765127
20129143051
20132—4193
201481272182
20153239264
20162—629
201752181149
20182—11,911
201942690114
20201—013
20210—07
20220—18
20232—027
20241—139
20250—122
20260—0—

What is it indicated for?

The ADVIA® Chemistry Fructosamine (FRUC) Assay

For in vitro diagnostic use in the quantitative measurement of glycated protein (fructosamine) in human serum or plasma on the ADVIA® Chemistry systems. Measurement of fructosamine is representative of blood glucose levels over the preceding 2-3 weeks, and is useful for monitoring diabetic patients.

ADVIA® Chemistry Fructosamine Calibrator

For in vitro diagnostic use in the calibration of the ADVIA® Chemistry Fructosamine (FRUC) assay on ADVIA® Chemistry systems.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K131307: Advia Chemistry Fructosamine Assay, Advia Chemistry Fructosamine Calibrator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K131307

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.