510(k) Report

510(k) · Cleared

Cleared

Mak Oss Femoral Knee Components

K131393510(k) TraditionalCleared Oct 24, 2013162-day reviewClass II21 CFR 888.3510

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biomet Orthopedics Corp. · KRO Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer

Cleared on Oct 24, 2013 as substantially equivalent to K083779 (Biomet Manufacturing Corp, 2009) and 1 other predicate after a 162-day review. Its family tree reaches back 4 generations to 2000.

Decided
Oct 24, 2013
Review
162 days
Class
Class II
Product code
KRO
Recalls
None
Predicates
2

Its longest line of descent runs back 4 generations to K002757 (2000). 6 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK002757 Oncology Salvage SystemBiomet, Inc. · 2000 · Recalled
  2. 3 generations backK021260 Reduced Size Oncology Salvage SystemBiomet, Inc. · 2002
  3. 2 generations backK051479 RS (Reduced Size) Oss (Orthopedic Salvage System) Additional…Biomet Manufacturing, Inc. · 2005
  4. 1 generation backK083779 Mak Oss Knee Femoral ComponentsBiomet Manufacturing Corp · 2009 · Recalled
  5. This deviceK131393 Mak Oss Femoral Knee ComponentsBiomet Orthopedics Corp. · 2013
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K002757Oncology Salvage SystemBiomet, Inc.200014
−3K021260Reduced Size Oncology Salvage SystemBiomet, Inc.2002—
−2K051479RS (Reduced Size) Oss (Orthopedic Salvage System) Additional ComponentsBiomet Manufacturing, Inc.2005—
−1K083779Mak Oss Knee Femoral ComponentsBiomet Manufacturing Corp20091
0 (this device)K131393Mak Oss Femoral Knee ComponentsBiomet Orthopedics Corp.2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200510
201310
FIG. 1 — Lineage of K131393, 2000–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KRO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KRO device

  1. #1 K251665 Triathlon® Hinge Knee Systemscore 19.0 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K083779Mak Oss Knee Femoral Components
Summary page 1
…RO) - Knee joint femorotibial metal/polymer constrained cemented prosthesis Legally Marketed Devices To Which Substantial Equivalence Is Claimed: K083779 - MAK OSS Femoral Knee Components (lBiomet) K 123501 -Orthopedic Salvage System (Biomet) Device Descriptio…
Biomet Manufacturing Corp20091
*K123501Oss Modular Stems, Oss Diaphyseal Segments
Summary page 1
…s Legally Marketed Devices To Which Substantial Equivalence Is Claimed: K083779 - MAK OSS Femoral Knee Components (lBiomet) K 123501 -Orthopedic Salvage System (Biomet) Device Description: The MAK 055 Femoral Knee Components are intended to be used as an option…
Biomet, Inc.2013—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 4 companies; a new generation was cleared every 3.6 years on median.
  • 3 of the 6 ancestors have a recall of any class.

How does its category compare?

All KRO devices

KRO Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · KRO

3in 2025

2007: 12008: 32009: 32010: 12011: 22012: 22013: 32014: 22015: 62016: 32017: 12019: 32020: 12021: 32022: 12023: 42024: 32025: 32026 (partial year): 1
2007high 6 (2015) · low 0 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KRO

56in 2025

2008: 126 days median2009: 86 days median2013: 189 days median2015: 113 days median2016: 148 days median2019: 244 days median2021: 57 days median2023: 148 days median2024: 87 days median2025: 56 days median
2007high 244 (2019) · low 56 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KRO

14so far in 2026, the most since 2007

2007: 12008: 32009: 82011: 12012: 12013: 22015: 12016: 52017: 42018: 12021: 12025: 12026 (partial year): 14
2007high 14 (2026) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KRO

915in 2025

2007: 372008: 442009: 662010: 1102011: 1192012: 1732013: 1942014: 4062015: 3332016: 3692017: 5432018: 6142019: 7592020: 7492021: 7702022: 8922023: 7462024: 8552025: 915
2007high 915 (2025) · low 37 (2007)2025

MAUDE reports naming product code KRO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—137
20083126344
2009386866
20101—0110
20112—1119
20122—1173
201331892194
20142—0406
201561131333
201631485369
20171—4543
20180—1614
201932440759
20201—0749
20213571770
20221—0892
202341480746
20243870855
20253561915
20261—14—

What is it indicated for?

Biomet's MAK OSS Femoral Knee Components are intended for use in conjunction with the OSS System for total knee replacement procedures. Specific indications for the OSS System are: 1. Painful and disabled joint resulting from avascular necrosis. osteoarthritis. rheumatoid arthritis, or traumatic arthritis. 2. Correction of varus, valgus or post-traumatic deformity. 3. Correction or revision of unsuccessful osteotomy, arthrodesis, or previous joint…

Read the full statement (188 words)

Biomet's MAK OSS Femoral Knee Components are intended for use in conjunction with the OSS System for total knee replacement procedures. Specific indications for the OSS System are:

1. Painful and disabled joint resulting from avascular necrosis. osteoarthritis. rheumatoid arthritis, or traumatic arthritis.

2. Correction of varus, valgus or post-traumatic deformity.

3. Correction or revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement.

4. Ligament deficiencies.

5. Tumor resections.

6. Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable by other techniques*

7. Revision of previously failed total joint arthroplasty.

8. Trauma.

These devices are to be used with bone cement unless a proximal femur is indicated for use (USA).

*Not applicable to Regenerex Ultra Porous Construct titanium knee augment usage (not licensed in Canada), or any other knee component.

When components of the Orthopedic Salvage System are used with Biomet's Compress Segmental Femoral Replacement System, they are intended for uncemented application and indicated for:

1. Correction or revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement.

2. Tumor resections.

3. Revision of previously failed total joint arthroplasty.

4. Trauma.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K131393: Mak Oss Femoral Knee Components.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K131393

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026