K140054510(k) TraditionalCleared May 16, 2014127-day reviewClass II21 CFR 868.5905

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Resmed, Ltd. · BZD Ventilator, Non-Continuous (Respirator)

Cleared on May 16, 2014 as substantially equivalent to K113815 (Resmed, Ltd., 2012) after a 127-day review. Its family tree reaches back 7 generations to 1997. 10 later devices descend from it.

Decided
May 16, 2014
Review
127 days
Class
Class II
Product code
BZD
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K971260 (1997). 13 ancestors in all, the oldest K930656 (1994). 10 later devices descend from it, 6 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 1 other ancestor2003: 1 other ancestor2002: 1 other ancestor1998: 1 other ancestor1996: 1 other ancestor1994: 1 other ancestor2015: 1 descendant cleared2025: 2 descendants cleared2016: 1 descendant cleared2026: 3 descendants cleared2019: 2 descendants cleared2020: 1 descendant clearedK971260 · Sullivan Humidaire Heated Humidifier · Resmed Corp · 1997K013909 · S7 Elite CP AP System · Resmed Corp · 2002K024191 · S7 Elite and Autoset Spirit Cpap Systems with Reslink · Resmed, Ltd. · 2003×2: 2 generations cleared close together, K033841 (2004), K041209 (2004) K050775 · Resscan · Resmed, Ltd. · 2005K113815 · Resscan · Resmed, Ltd. · 20121990200020102020
Other ancestors, by generationDescendants, by generation 3 generations back: 1 other ancestor4 generations back: 2 other ancestors5 generations back: 3 other ancestors 1 generation forward: 6 descendants2 generations forward: 3 descendants3 generations forward: 1 descendant K113815 · Resscan · Resmed, Ltd. · 2012K050775 · Resscan · Resmed, Ltd. · 2005K041209 · Resmed S8 Pioneer Cpap System · Resmed, Ltd. · 2004 · recalledK033841 · Resmed S8 Prime Cpap System · Resmed, Ltd. · 2004 · recalledK024191 · S7 Elite and Autoset Spirit Cpap Systems with Reslink · Resmed, Ltd. · 2003K013909 · S7 Elite CP AP System · Resmed Corp · 2002K971260 · Sullivan Humidaire Heated Humidifier · Resmed Corp · 1997−50
  1. Root · 7 generations backK971260 Sullivan Humidaire Heated HumidifierResmed Corp · 1997
  2. 6 generations backK013909 S7 Elite CP AP SystemResmed Corp · 2002
  3. 5 generations backK024191 S7 Elite and Autoset Spirit Cpap Systems with ReslinkResmed, Ltd. · 2003
  4. 4 generations backK033841 Resmed S8 Prime Cpap SystemResmed, Ltd. · 2004 · Recalled
  5. 3 generations backK041209 Resmed S8 Pioneer Cpap SystemResmed, Ltd. · 2004 · Recalled
  6. 2 generations backK050775 ResscanResmed, Ltd. · 2005
  7. 1 generation backK113815 ResscanResmed, Ltd. · 2012
  8. This deviceK140054 RescanResmed, Ltd. · 2014
  9. Descendant · cites it directly · 4 of its ownK152356 SapphireRespironics, Inc. · 2016
  10. Descendant · 2 generations on · 1 of its ownK181053 Care OrchestratorRespironics, Inc. · 2019
  11. Descendant · cites it directly · 1 of its ownK151901 AirViewResmed, Ltd. · 2015
  12. Descendant · cites it directly · 0 of its ownK253553 OrionResmed Corp · 2026
  13. Descendant · cites it directly · 0 of its ownK252802 Peak Flow Meter (PF-10(BR-PEF231))Shenzhen Bi-Rich Medical Devices Co., Ltd. · 2026

Showing 5 of 10 descendants. See all descendants

Descendants cleared per year

2015: 12016: 12019: 22020: 12025: 22026: 3
2015high 3 (2026) · low 0 (2017)2026

Most influential descendants

Showing 5 of 10 · See all
  • K152356SapphireRespironics, Inc. · 2016 · cites it directly4descendants
  • K181053Care OrchestratorRespironics, Inc. · 2019 · 2 generations on1descendant
  • K151901AirViewResmed, Ltd. · 2015 · cites it directly1descendant
  • K253553OrionResmed Corp · 2026 · cites it directly0descendants
  • K252802Peak Flow Meter (PF-10(BR-PEF231))Shenzhen Bi-Rich Medical Devices Co., Ltd. · 2026 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K971260Sullivan Humidaire Heated HumidifierResmed Corp1997—
−6K013909S7 Elite CP AP SystemResmed Corp2002—
−5K024191S7 Elite and Autoset Spirit Cpap Systems with ReslinkResmed, Ltd.2003—
−4K033841Resmed S8 Prime Cpap SystemResmed, Ltd.20041
−3K041209Resmed S8 Pioneer Cpap SystemResmed, Ltd.20041
−2K050775ResscanResmed, Ltd.2005—
−1K113815ResscanResmed, Ltd.2012—
0 (this device)K140054RescanResmed, Ltd.2014—
+1K152356SapphireRespironics, Inc.2016—
+2K181053Care OrchestratorRespironics, Inc.2019—
+1K151901AirViewResmed, Ltd.2015—
+1K253553OrionResmed Corp2026—
+1K252802Peak Flow Meter (PF-10(BR-PEF231))Shenzhen Bi-Rich Medical Devices Co., Ltd.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199610
199810
200210
200310
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201510
201610
201920
202010
202520
202630
FIG. 1 — Lineage of K140054, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BZD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZD device

  1. #1 K250624 myAirscore 15.7 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K113815Resscan
Summary page 1
…21 CFR 868.5895, 73 CBK (Class 11) Ventilator, continuous, facility use Legally Marketed ResScan (K113815) Predicate Device Reason for Submission New Device Indication for Use ResScan is intended to augment…
Resmed, Ltd.2012—

Also cleared against K113815: 1 other device →

What descends from it? (10)

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K152356SapphireRespironics, Inc.20164
K151901AirViewResmed, Ltd.20151
K253553OrionResmed Corp20260
K252802Peak Flow Meter (PF-10(BR-PEF231))Shenzhen Bi-Rich Medical Devices Co., Ltd.20260
K254104ResScan EssentialsResmed Corp20260
K242935Respiration Data Management Software (PAP Link PC)BMC Medical Co., Ltd.20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 2 companies; a new generation was cleared every 12 months on median.
  • 2 of the 13 ancestors have a recall of any class.
  • Of its descendants, K152356 (Respironics, Inc., 2016) has gone furthest, with 4 descendants of its own.
  • 1 other device also cites its predicate K113815.

How does its category compare?

All BZD devices

BZD Ventilator, Non-Continuous (Respirator): FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · BZD

7in 2025

2007: 212008: 172009: 232010: 122011: 232012: 212013: 232014: 142015: 112016: 122017: 52018: 52019: 62020: 62021: 62022: 42023: 52024: 102025: 72026 (partial year): 10
2007high 23 (2009) · low 4 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZD

189in 2025

2007: 83 days median2008: 108 days median2009: 90 days median2010: 122 days median2011: 125 days median2012: 133 days median2013: 127 days median2014: 172 days median2015: 224 days median2016: 217 days median2017: 221 days median2018: 280 days median2019: 231 days median2020: 137 days median2021: 192 days median2022: 253 days median2023: 204 days median2024: 132 days median2025: 189 days median2026 (partial year): 214 days median
2007high 280 (2018) · low 83 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BZD

8in 2023

2007: 292008: 22009: 12011: 12019: 4, 4 Class I2023: 8, 7 Class I2026 (partial year): 2, 2 Class I
2007high 29 (2007) · low 0 (2010)2026

Class I (13 since 2007) Class II/III not classified

Adverse event reports per year · BZD

60,279in 2025

2007: 652008: 672009: 1472010: 1432011: 1892012: 1392013: 822014: 862015: 1142016: 1182017: 1482018: 1012019: 1882020: 1262021: 6,0662022: 90,7682023: 27,9872024: 68,2622025: 60,279
2007high 90,768 (2022) · low 65 (2007)2025

MAUDE reports naming product code BZD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200721832965
200817108267
200923901147
2010121220143
2011231251189
2012211330139
201323127082
201414172086
2015112240114
2016122170118
201752210148
201852800101
201962314 (4)188
202061370126
2021619206,066
20224253090,768
202352048 (7)27,987
202410132068,262
20257189060,279
2026102142 (2)—

What is it indicated for?

ResScan is intended to augment the standard follow-up care of patients by providing transfer of machine and therapeutic information. This includes the ability to remotely change settings in non-life support devices only.

It is intended to be used by Clinicians in conjunction with ResMed compatible therapy devices, using ResMed's proprietary communications protocol.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K140054: Rescan.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K140054

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026