510(k) Report

510(k) · Cleared

Cleared

Masimo Root Monitoring System

K140188510(k) TraditionalCleared Jun 25, 2014152-day reviewClass II21 CFR 870.2300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Masimo Corporation · MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)

Cleared on Jun 25, 2014 as substantially equivalent to K121013 (Welch Allyn, Inc., 2012) and 3 other predicates after a 152-day review. Its family tree reaches back 16 generations to 1997. 1 of the 135 devices in its family, counting itself, has a Class I recall. 58 later devices descend from it.

Decided
Jun 25, 2014
Review
152 days
Class
Class II
Product code
MWI
Recalls
None
Predicates
4

Its longest line of descent runs back 16 generations to K962603 (1997). 76 ancestors in all, the oldest K853990 (1985). 58 later devices descend from it, 2 citing it directly. 1 of the 135 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2011: 2 other ancestors2005: 4 other ancestors2010: 3 other ancestors2004: 6 other ancestors2002: 5 other ancestors2008: 1 other ancestor2003: 5 other ancestors2001: 1 other ancestor2000: 6 other ancestors1996: 3 other ancestors2006: 3 other ancestors1999: 3 other ancestors1995: 5 other ancestors1985: 1 other ancestor1990: 2 other ancestors1998: 4 other ancestors1997: 2 other ancestors, 1 with a Class I recall11991: 2 other ancestors1993: 1 other ancestor1992: 1 other ancestor2014: 1 descendant cleared2018: 2 descendants cleared2016: 2 descendants cleared2015: 1 descendant cleared2023: 6 descendants cleared2022: 9 descendants cleared2019: 5 descendants cleared2017: 2 descendants cleared2026: 6 descendants cleared2025: 8 descendants cleared2020: 5 descendants cleared2024: 10 descendants cleared2021: 1 descendant clearedReference device: K071047 · Masimo Patient Safety Net · Masimo Corporation · 2007K962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 1997K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K982255 · Model 2000 Pulse Oximeter · Ivy Biomedical Systems, Inc. · 1998K991823 · N-395 Pulse Oximeter, Model N-395 · Nellcor Puritan Bennett, Inc. · 1999×2: 2 generations cleared close together, K012891 (2002), K021090 (2002) K033048 · Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL, 740M-2NL, 740-2NN, 740M-2NN, 740-3MS, 740M-3MS · Cas Medical Systems, Inc. · 2004 · recalledK050844 · 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL, 750C-3MS, 750CM-3MS, 750C-3NL, 750CM-3NL · Cas Medical Systems, Inc. · 2005K060065 · CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter Bedside Monitor · Oridion Capnography, Inc. · 2006 · recalledK072295 · Capnostream 20 with A2 Adaptive Averaging Software · Oridion Capnography, Inc. · 2007K082268 · CAPNOSTREAM20 with Integrated Pulmonary Index · Oridion Capnography, Inc. · 2009 · recalledK091241 · Masimo Rainbow Set Radical 7 Pulse CO-Oximeter; Rad 87 Pulse CO-Oximeter · Masimo Corporation · 2009K100428 · Masimo Rainbow Set Radical 7R Pulse CO-Oximeter · Masimo Corporation · 2010K110516 · Connex Vital Signs Monitor 6000 Series · Welch Allyn, Inc. · 2011K112687 · Connex (R) Vital Signs Monitor 6000 Series · Welch Allyn, Inc. · 2011K121013 · Connex Vital Signs Monitor 6000 Series · Welch Allyn, Inc. · 20121990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors2 generations back: 5 other ancestors3 generations back: 8 other ancestors4 generations back: 10 other ancestors5 generations back: 8 other ancestors6 generations back: 7 other ancestors7 generations back: 7 other ancestors8 generations back: 5 other ancestors, 1 with a Class I recall19 generations back: 5 other ancestors10 generations back: 2 other ancestors 1 generation forward: 2 descendants2 generations forward: 5 descendants3 generations forward: 6 descendants4 generations forward: 12 descendants5 generations forward: 21 descendants6 generations forward: 11 descendants7 generations forward: 1 descendant K121013 · Connex Vital Signs Monitor 6000 Series · Welch Allyn, Inc. · 2012K112687 · Connex (R) Vital Signs Monitor 6000 Series · Welch Allyn, Inc. · 2011K110516 · Connex Vital Signs Monitor 6000 Series · Welch Allyn, Inc. · 2011K100428 · Masimo Rainbow Set Radical 7R Pulse CO-Oximeter · Masimo Corporation · 2010K091241 · Masimo Rainbow Set Radical 7 Pulse CO-Oximeter; Rad 87 Pulse CO-Oximeter · Masimo Corporation · 2009K082268 · CAPNOSTREAM20 with Integrated Pulmonary Index · Oridion Capnography, Inc. · 2009 · recalledK072295 · Capnostream 20 with A2 Adaptive Averaging Software · Oridion Capnography, Inc. · 2007K060065 · CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter Bedside Monitor · Oridion Capnography, Inc. · 2006 · recalledK050844 · 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL, 750C-3MS, 750CM-3MS, 750C-3NL, 750CM-3NL · Cas Medical Systems, Inc. · 2005K033048 · Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL, 740M-2NL, 740-2NN, 740M-2NN, 740-3MS, 740M-3MS · Cas Medical Systems, Inc. · 2004 · recalledK021090 · Oximax N-550 Pulse Oximeter,Model N-550 Pulse Oximeter · Nellcor Puritan Bennett, Inc. · 2002K012891 · Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and Cables (Aka Accessories) · Nellcor Puritan Bennett, Inc. · 2002 · recalledK991823 · N-395 Pulse Oximeter, Model N-395 · Nellcor Puritan Bennett, Inc. · 1999K982255 · Model 2000 Pulse Oximeter · Ivy Biomedical Systems, Inc. · 1998K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 1997−15−10−50+5
  1. Root · 16 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 12 generations between
  3. 3 generations backK110516 Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc. · 2011
  4. 2 generations backK112687 Connex (R) Vital Signs Monitor 6000 SeriesWelch Allyn, Inc. · 2011
  5. 1 generation backK121013 Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc. · 2012
  6. This deviceK140188 Masimo Root Monitoring SystemMasimo Corporation · 2014
  7. Descendant · cites it directly · 51 of its ownK142394 Masimo Root Monitoring System and AccesoriesMasimo Corporation · 2014
  8. Descendant · 2 generations on · 24 of its ownK151644 Masimo Root Vital Signs Monitoring System and AccessoriesMasimo Corporation · 2016
  9. Descendant · 2 generations on · 24 of its ownK150314 Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation · 2015
  10. Descendant · 3 generations on · 23 of its ownK181956 Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation · 2019
  11. Descendant · 3 generations on · 16 of its ownK171121 Masimo Root Monitoring System and AccessoriesMasimo Corporation · 2017
Show all 16 generations
  1. Root · 16 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 15 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
  3. 14 generations backK982255 Model 2000 Pulse OximeterIvy Biomedical Systems, Inc. · 1998
  4. 13 generations backK991823 N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc. · 1999
  5. 12 generations backK012891 Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax…Nellcor Puritan Bennett, Inc. · 2002 · Recalled
  6. 11 generations backK021090 Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc. · 2002
  7. 10 generations backK033048 Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS…Cas Medical Systems, Inc. · 2004 · Recalled
  8. 9 generations backK050844 750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL…Cas Medical Systems, Inc. · 2005
  9. 8 generations backK060065 CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One…Oridion Capnography, Inc. · 2006 · Recalled
  10. 7 generations backK072295 Capnostream 20 with A2 Adaptive Averaging SoftwareOridion Capnography, Inc. · 2007
  11. 6 generations backK082268 CAPNOSTREAM20 with Integrated Pulmonary IndexOridion Capnography, Inc. · 2009 · Recalled
  12. 5 generations backK091241 Masimo Rainbow Set Radical 7 Pulse CO-Oximeter; Rad 87 Pulse…Masimo Corporation · 2009
  13. 4 generations backK100428 Masimo Rainbow Set Radical 7R Pulse CO-OximeterMasimo Corporation · 2010
  14. 3 generations backK110516 Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc. · 2011
  15. 2 generations backK112687 Connex (R) Vital Signs Monitor 6000 SeriesWelch Allyn, Inc. · 2011
  16. 1 generation backK121013 Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc. · 2012
  17. This deviceK140188 Masimo Root Monitoring SystemMasimo Corporation · 2014

Showing 5 of 58 descendants. See all descendants

Descendants cleared per year

2014: 12015: 12016: 22017: 22018: 22019: 52020: 52021: 12022: 92023: 62024: 102025: 82026: 6
2014high 10 (2024) · low 1 (2014)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 58 · See all
  • K142394Masimo Root Monitoring System and AccesoriesMasimo Corporation · 2014 · cites it directly51descendants
  • K151644Masimo Root Vital Signs Monitoring System and AccessoriesMasimo Corporation · 2016 · 2 generations on24descendants
  • K150314Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation · 2015 · 2 generations on24descendants
  • K181956Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation · 2019 · 3 generations on23descendants
  • K171121Masimo Root Monitoring System and AccessoriesMasimo Corporation · 2017 · 3 generations on16descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−16K962603Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp.1997—
−15K973887Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and CablesMasimo Corp.1998—
−14K982255Model 2000 Pulse OximeterIvy Biomedical Systems, Inc.1998—
−13K991823N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc.1999—
−12K012891Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and…Nellcor Puritan Bennett, Inc.20021
−11K021090Oximax N-550 Pulse Oximeter,Model N-550 Pulse OximeterNellcor Puritan Bennett, Inc.2002—
−10K033048Cas 740 Series Monitor, Models 740-1, 740M-1, 740-2MS, 740M-2MS, 740-2NL…Cas Medical Systems, Inc.20041
−9K050844750C Series Monitor, Models 750C-2MS, 750CM-2MS, 750C-NNL, 750CM-2NL…Cas Medical Systems, Inc.2005—
−8K060065CAPNOSTREAM20 Two Parameter Bedside Monitor & CAPNOSTREAM10 One Parameter…Oridion Capnography, Inc.20063
−7K072295Capnostream 20 with A2 Adaptive Averaging SoftwareOridion Capnography, Inc.2007—
−6K082268CAPNOSTREAM20 with Integrated Pulmonary IndexOridion Capnography, Inc.20099
−5K091241Masimo Rainbow Set Radical 7 Pulse CO-Oximeter; Rad 87 Pulse CO-OximeterMasimo Corporation2009—
−4K100428Masimo Rainbow Set Radical 7R Pulse CO-OximeterMasimo Corporation2010—
−3K110516Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc.2011—
−2K112687Connex (R) Vital Signs Monitor 6000 SeriesWelch Allyn, Inc.2011—
−1K121013Connex Vital Signs Monitor 6000 SeriesWelch Allyn, Inc.2012—
0 (this device)K140188Masimo Root Monitoring SystemMasimo Corporation2014—
+1K142394Masimo Root Monitoring System and AccesoriesMasimo Corporation2014—
+2K151644Masimo Root Vital Signs Monitoring System and AccessoriesMasimo Corporation2016—
+2K150314Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation2015—
+3K181956Masimo MightySat Rx Fingertip Pulse OximeterMasimo Corporation2019—
+3K171121Masimo Root Monitoring System and AccessoriesMasimo Corporation2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
199020
199120
199210
199310
199550
199630
199721
199840
199930
200060
200110
200250
200350
200460
200540
200630
200810
201030
201120

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
201510
201620
201720
201820
201950
202050
202110
202290
202360
2024100
202580
202660
FIG. 1 — Lineage of K140188, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MWI device

  1. #1 K230457 Empatica Health Monitoring Platform…score 28.0 · 39 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K121013Connex Vital Signs Monitor 6000 Series
Summary page 1
…stablishment Registration 2031172 Number: Reason for Premarket Device modification and new indications for use Notification: Predicate Devices: K1 21013 - Welch Allyn Connex Vital Signs Monitor 6000 Series Ki…
Welch Allyn, Inc.2012—
*K110028Masimo Radical Y Pulse CO-Oximeter
Summary page 3
…Color LCD touchscreen Cneced Meol" Paranieter Radical 7 Parameters per K 110028 ISA Module Parameters per K 103604 Sedline Module Par…
Masimo Corporation2011—
*K103604Isa CO2, Isa AX+, Isa or+
Summary page 1
…es Ki 10028 - Masimo Radical 7 Pulse CO-oximeter and Accessories K 103604 - ISA-Infrared Sidestreamn Gas Analyzer K05 1874 - Sedline Sedation Monitor with Frontal PSI and…
Phasein AB2011—
*K051874Sedline Sedation Monitor with Frontal Psi and Sedtrace Eeg Electrose Set
Summary page 1
…and Accessories K 103604 - ISA-Infrared Sidestreamn Gas Analyzer K05 1874 - Sedline Sedation Monitor with Frontal PSI and SEDTrace EEG Electrode Set Performance…
Physiometrix, Inc.2005—
†K071047Masimo Patient Safety NetMasimo Corporation2007—

Also cleared against K121013: 2 other devices →

What descends from it? (58)

See all 58

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K142394Masimo Root Monitoring System and AccesoriesMasimo Corporation201451
K172890SedLine Sedation MonitorMasimo Corporation20185

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K970209Capnocheck PlusBci Intl., Inc. · 1997 · 8 generations back · ◆ in the 1997 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 17 years and passes through 7 companies; a new generation was cleared every 11 months on median.
  • 15 of the 76 ancestors have a recall of any class; 1 has a Class I recall.
  • Of its descendants, K142394 (Masimo Corporation, 2014) has gone furthest, with 51 descendants of its own.
  • 2 other devices also cite its predicate K121013.

How does its category compare?

All MWI devices

MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · MWI

4in 2025

2007: 92008: 92009: 62010: 172011: 112012: 132013: 202014: 162015: 192016: 122017: 132018: 112019: 142020: 82021: 92022: 52023: 82024: 102025: 42026 (partial year): 6
2007high 20 (2013) · low 4 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MWI

247in 2025

2007: 42 days median2008: 49 days median2009: 112 days median2010: 58 days median2011: 78 days median2012: 104 days median2013: 85 days median2014: 148 days median2015: 127 days median2016: 165 days median2017: 205 days median2018: 217 days median2019: 255 days median2020: 138 days median2021: 161 days median2022: 231 days median2023: 250 days median2024: 202 days median2025: 247 days median2026 (partial year): 239 days median
2007high 255 (2019) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MWI

9so far in 2026, the most since 2007

2007: 12008: 12009: 22010: 22011: 32012: 52013: 32014: 62015: 12017: 22019: 42022: 22024: 52026 (partial year): 9
2007high 9 (2026) · low 0 (2016)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MWI

182in 2025

2007: 32008: 32009: 202010: 172011: 162012: 312013: 422014: 302015: 312016: 512017: 852018: 1582019: 1692020: 1102021: 1882022: 1682023: 1792024: 1202025: 182
2007high 188 (2021) · low 3 (2007)2025

MAUDE reports naming product code MWI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200794213
200894913
20096112220
20101758217
20111178316
201213104531
20132085342
201416148630
201519127131
201612165051
201713205285
2018112170158
2019142554169
202081380110
202191610188
202252312168
202382500179
2024102025120
202542470182
202662399—

What is it indicated for?

The Masimo Root Monitoring System is indicated for use by healthcare professionals for the monitoring of multiple physiological parameters in healthcare environments. The Masimo Root Monitoring System can transmit data for supplemental remote viewing and alarming (e.g., at a central station). The optional Masimo Radical 7 Pulse CO-Oximeter and Accessories are indicated for the continuous non-invasive monitoring of functional oxygen saturation of arterial…

Read the full statement (361 words)

The Masimo Root Monitoring System is indicated for use by healthcare professionals for the monitoring of multiple physiological parameters in healthcare environments.

The Masimo Root Monitoring System can transmit data for supplemental remote viewing and alarming (e.g., at a central station).

The optional Masimo Radical 7 Pulse CO-Oximeter and Accessories are indicated for the continuous non-invasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2), pulse rate, carboxyhernoglobin saturation (SpCO), methemoglobin saturation (SpMet), total hemoglobin concentration (SpHb), and/or respiratory rate (RRa). The Masimo Radical 7 Pulse CO-Oximeter and accessories are indicated for use with adult, pediatric, and neonatal patients during both no motion and motion conditions, and for patients who are well or poorly perfused in hospitals, hospital-type facilities, mobile, and home environments. In addition, the Masimo Radical 7 Pulse CO-Oximeter and accessories are indicated to provide the continuous non-invasive monitoring data obtained from the Masimo Radical 7 Pulse CO-Oximeter and accessories of functional oxygen saturation of arterial hemoglobin (SPO2) and pulse rate to multi-parameter devices for the display of those devices.

The optional ISA product family consists of three types of sidestreamn gas analyzers (ISA C02, ISA AX+ and ISA OR+), intended to be connected to other medical backboard devices for monitoring of breath rate and the following breathing gases:

ISA C02: CO2

ISA AX+: C02, N2 0, Halothane, Isaflurane, Enflurane, Sevoflurane and Desfiurane

ISA OR+: COL, 02, N20, Halothane, Isoflurane, Enflurane, Sevoflurane and Desfiurane

ISA C02, ISA AX+ and ISA OR+ are intended to be connected to a patient breathing circuit for monitoring of inspired/expired gases during anesthesia, recovery and respiratory care. The intended environment is the operating suite, intensive care unit and patient room. ISA C02 is also intended to be used in road ambulances. The intended patient population is adult, pediatric and infant patients.

The optional SEDLine Sedation Monitor is indicated for use in the operating roam (OR), intensive care unit (ICU), and clinical research laboratory. It is intended to monitor the state of the brain by real-time data acquisition and processing of EEG signals. The system includes the Patient State Index (PSI), a proprietary computed EEG variable that is related to the effect of anesthetic agents.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K140188: Masimo Root Monitoring System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K140188

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026