510(k) Report

510(k) · Cleared

Cleared

Mustang Balloon Dialation Catheter

K141597510(k) SpecialCleared Aug 22, 201470-day reviewClass II21 CFR 876.5010

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Boston Scientific Corporation · FGE Stents, Drains And Dilators For The Biliary Ducts

Cleared on Aug 22, 2014 as substantially equivalent to K110122 (Boston Scientific, 2011) and 1 other predicate after a 70-day review. Its family tree reaches back 8 generations to 2000.

Decided
Aug 22, 2014
Review
70 days
Class
Class II
Product code
FGE
Recalls
None
Predicates
2

Its longest line of descent runs back 8 generations to K001134 (2000). 15 ancestors in all, the oldest K993303 (2000). No later device cites it as a predicate yet.

  1. Root · 8 generations backK001134 Gazelle Balloon Dilatation CatheterBoston Scientific Corp · 2000
  2. 7 generations backK021735 Boston Scientific Ultra-Soft SV Balloon Dilatation CatheterBoston Scientific Scimed, Inc. · 2002 · Recalled
  3. 6 generations backK050389 Ultra-Soft SV Balloon Dilatation CatheterBoston Scientific Corp · 2005
  4. 5 generations backK053116 Sterling Otw Pta Balloon Dilatation Catheter, Model H74939032-XxxxxxBoston Scientific Corp · 2005
  5. 4 generations backK072283 Dorado Pta Balloon Dilatation CatheterBard Peripheral Vascular, Inc. · 2007 · Recalled
  6. 3 generations backK103751 Mustang Balloon Dilatation CathetersBoston Scientific · 2011
  7. 2 generations backK113681 Gladiator Pta Balloon Dilation CatheterBoston Scientific · 2012
  8. 1 generation backK132810 Gladiator Elite Pta Balloon Dilatation CatheterBoston Scientific Corp · 2014
  9. This deviceK141597 Mustang Balloon Dialation CatheterBoston Scientific Corporation · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K001134Gazelle Balloon Dilatation CatheterBoston Scientific Corp2000—
−7K021735Boston Scientific Ultra-Soft SV Balloon Dilatation CatheterBoston Scientific Scimed, Inc.200223
−6K050389Ultra-Soft SV Balloon Dilatation CatheterBoston Scientific Corp2005—
−5K053116Sterling Otw Pta Balloon Dilatation Catheter, Model H74939032-XxxxxxBoston Scientific Corp2005—
−4K072283Dorado Pta Balloon Dilatation CatheterBard Peripheral Vascular, Inc.200715
−3K103751Mustang Balloon Dilatation CathetersBoston Scientific2011—
−2K113681Gladiator Pta Balloon Dilation CatheterBoston Scientific2012—
−1K132810Gladiator Elite Pta Balloon Dilatation CatheterBoston Scientific Corp2014—
0 (this device)K141597Mustang Balloon Dialation CatheterBoston Scientific Corporation2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200020
200110
200210
200510
200610
201110
FIG. 1 — Lineage of K141597, 2000–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FGE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FGE device

  1. #1 K240464 WallFlex Biliary RX Stent System; Epic Biliary…score 14.5 · 13 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K110122Mustang Balloon Dilataion Catheters
Summary page 4
…Code FGE – Catheter, Biliary, Diagnostic Classification Class II, 21 CFR Part 876.5010 Predicate Mustang™ Balloon Dilatation K110122 12 May 2011 Device(s) Catheter Gladiator Elite ™ Balloon Dilatation…
Boston Scientific2011—
*K132810Gladiator Elite Pta Balloon Dilatation Catheter
Summary page 4
…12 May 2011 Device(s) Catheter Gladiator Elite ™ Balloon Dilatation Catheter K132810 28 February 2014 Device Mustang Balloon Dilatation Catheters are over-the-wire balloon catheters with Descr…
Boston Scientific Corp2014—

Also cleared against K110122: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 5 companies; a new generation was cleared every 1.9 years on median.
  • 2 of the 15 ancestors have a recall of any class.
  • 1 other device also cites its predicate K110122.

How does its category compare?

All FGE devices

FGE Stents, Drains And Dilators For The Biliary Ducts: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · FGE

7in 2025

2007: 42008: 112009: 72010: 92011: 92012: 82013: 52014: 82015: 82016: 42017: 92018: 72019: 22020: 42021: 12022: 62023: 62024: 62025: 72026 (partial year): 8
2007high 11 (2008) · low 1 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FGE

257in 2025

2007: 316 days median2008: 214 days median2009: 160 days median2010: 81 days median2011: 114 days median2012: 96 days median2013: 161 days median2014: 156 days median2015: 79 days median2016: 49 days median2017: 59 days median2018: 215 days median2020: 121 days median2022: 101 days median2023: 199 days median2024: 188 days median2025: 257 days median2026 (partial year): 153 days median
2007high 316 (2007) · low 49 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FGE

1in 2024

2007: 542008: 932009: 182010: 322011: 22012: 42013: 32017: 12018: 432019: 132020: 12021: 272022: 212023: 192024: 12026 (partial year): 11
2007high 93 (2008) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FGE

1,923in 2025

2007: 1,0062008: 1,4652009: 1,6552010: 1,4342011: 1,3212012: 1,1832013: 1,0602014: 1,2702015: 1,5432016: 1,4532017: 1,5152018: 1,6812019: 1,8962020: 2,1822021: 2,2972022: 1,7492023: 1,6152024: 1,9482025: 1,923
2007high 2,297 (2021) · low 1,006 (2007)2025

MAUDE reports naming product code FGE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074316541,006
200811214931,465
20097160181,655
2010981321,434
2011911421,321
201289641,183
2013516131,060
2014815601,270
201587901,543
201644901,453
201795911,515
20187215431,681
20192—131,896
2020412112,182
20211—272,297
20226101211,749
20236199191,615
2024618811,948
2025725701,923
2026815311—

What is it indicated for?

The Mustang ™ Balloon Dilatation Catheters with balloons up to 120mm in length are indicated for the treatment of biliary strictures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K141597: Mustang Balloon Dialation Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K141597

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026