510(k) Report

510(k) · Cleared

Cleared

Nephros Dsu-H, Nephros Ssu-H

K141731510(k) TraditionalCleared Oct 24, 2014119-day reviewClass II21 CFR 876.5665

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Nephros, Inc. · NHV System, Water Purification, General Medical Use

Cleared on Oct 24, 2014 as substantially equivalent to K012716 (Prismedical Corp., 2002) after a 119-day review. Its family tree reaches back 2 generations to 2001. 9 later devices descend from it.

Decided
Oct 24, 2014
Review
119 days
Class
Class II
Product code
NHV
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K002045 (2001). 9 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2016: 3 descendants cleared2019: 2 descendants cleared2023: 1 descendant cleared2017: 1 descendant cleared2018: 1 descendant cleared2026: 1 descendant clearedReference device: K110285 · Nephros Dsu Filter, Nephros Msu Filter, Nephros Ssu Filter · Nephros, Inc. · 2011K002045 · Water Purification System for Hemodialysis · Total Water Treatment Systems, Inc. · 2001K012716 · Mainstream Water Purification Device · Prismedical Corp. · 2002200020052010201520202025
Descendants, by generation 1 generation forward: 3 descendants2 generations forward: 4 descendants3 generations forward: 2 descendants K012716 · Mainstream Water Purification Device · Prismedical Corp. · 2002K002045 · Water Purification System for Hemodialysis · Total Water Treatment Systems, Inc. · 20010
  1. Root · 2 generations backK002045 Water Purification System for HemodialysisTotal Water Treatment Systems, Inc. · 2001
  2. 1 generation backK012716 Mainstream Water Purification DevicePrismedical Corp. · 2002
  3. This deviceK141731 Nephros Dsu-H, Nephros Ssu-HNephros, Inc. · 2014
  4. Descendant · cites it directly · 4 of its ownK153784 Nosogard FiltersEvoqua Water Technologies, LLC · 2016
  5. Descendant · cites it directly · 4 of its ownK153434 Pall-Aquasafe Water FilterPall International Sarl · 2016
  6. Descendant · cites it directly · 2 of its ownK153084 Nephros S100Nephros, Inc. · 2016
  7. Descendant · 2 generations on · 1 of its ownK191563 FILTRAY 2G Disposable Water FiltersAqua-Tools · 2019
  8. Descendant · 2 generations on · 1 of its ownK173164 Ecolab POU Water FilterEcolab, Inc. · 2018

Showing 5 of 9 descendants. See all descendants

Descendants cleared per year

2016: 32017: 12018: 12019: 22023: 12026: 1
2016high 3 (2016) · low 0 (2020)2026

Most influential descendants

Showing 5 of 9 · See all
  • K153784Nosogard FiltersEvoqua Water Technologies, LLC · 2016 · cites it directly4descendants
  • K153434Pall-Aquasafe Water FilterPall International Sarl · 2016 · cites it directly4descendants
  • K153084Nephros S100Nephros, Inc. · 2016 · cites it directly2descendants
  • K191563FILTRAY 2G Disposable Water FiltersAqua-Tools · 2019 · 2 generations on1descendant
  • K173164Ecolab POU Water FilterEcolab, Inc. · 2018 · 2 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K002045Water Purification System for HemodialysisTotal Water Treatment Systems, Inc.2001—
−1K012716Mainstream Water Purification DevicePrismedical Corp.2002—
0 (this device)K141731Nephros Dsu-H, Nephros Ssu-HNephros, Inc.2014—
+1K153784Nosogard FiltersEvoqua Water Technologies, LLC2016—
+1K153434Pall-Aquasafe Water FilterPall International Sarl2016—
+1K153084Nephros S100Nephros, Inc.2016—
+2K191563FILTRAY 2G Disposable Water FiltersAqua-Tools2019—
+2K173164Ecolab POU Water FilterEcolab, Inc.2018—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201630
201710
201810
201920
202310
202610
FIG. 1 — Lineage of K141731, 2001–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NHV? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NHV device

  1. #1 K261470 QF10score 13.2 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K012716Mainstream Water Purification Device
Summary page 5
…6.5665 Water Purification Device, General and Number Medical Use Product Code NHV Predicate Device MainStream™ Water Purification Device – K012716 Reference Devices DSU and SSU Filters – K110285 Device Description The DSU-H and SSU-H Ultrafilters are hollow fiber u…
Prismedical Corp.2002—
†K110285Nephros Dsu Filter, Nephros Msu Filter, Nephros Ssu FilterNephros, Inc.2011—

Also cleared against K012716: 1 other device →

What descends from it? (9)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K153784Nosogard FiltersEvoqua Water Technologies, LLC20164
K153434Pall-Aquasafe Water FilterPall International Sarl20164
K153084Nephros S100Nephros, Inc.20162

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 3 companies; a new generation was cleared every 12.5 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K153784 (Evoqua Water Technologies, LLC, 2016) has gone furthest, with 4 descendants of its own.
  • 1 other device also cites its predicate K012716.

How does its category compare?

All NHV devices

NHV System, Water Purification, General Medical Use: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · NHV

1in 2023

2014: 12016: 42017: 12018: 12019: 22023: 12026 (partial year): 1
2007high 4 (2016) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NHV

203in 2016

2016: 203 days median
2007high 203 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NHV

No recall names NHV since 2007.

Adverse event reports per year · NHV

1in 2025

2017: 12018: 22019: 12022: 42025: 1
2007high 4 (2022) · low 0 (2007)2025

MAUDE reports naming product code NHV, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20141—00
20150—00
2016420300
20171—01
20181—02
20192—01
20200—00
20210—00
20220—04
20231—00
20240—00
20250—01
20261—0—

What is it indicated for?

The DSU-H and SSU-H Ultrafilters are intended to be used to filter EPA quality drinking water. The filters retain bacteria, viruses and endotoxin. By providing ultrapure water for patient washing and drinking, the filters aid in infection control. The filters produce water that is suitable for wound cleansing, cleaning of equipment used in medical procedures and washing of surgeon’s hands. The filters are not intended to provide water that can be used as a substitute for USP sterile water.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K141731: Nephros Dsu-H, Nephros Ssu-H.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K141731

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026