Healgen Scientific,, LLC · DJG Enzyme Immunoassay, Opiates
Cleared on Oct 16, 2014 as substantially equivalent to K052115 (First Check Diagnostics, LLC, 2005) after a 62-day review. Its family tree reaches back 2 generations to 2005. 4 later devices descend from it.
- Decided
- Oct 16, 2014
- Review
- 62 days
- Class
- Class II
- Product code
- DJG
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K050186 (2005). 4 later devices descend from it, 4 citing it directly.
- Root · 2 generations backK050186 Ameditech Immutest Multi-Drug Screen Panel IiiAmeditech, Inc. · 2005 · Recalled
- 1 generation backK052115 First Check Multi Drug Cup 12 for Marijuana (THC), Cocaine (Coc)…First Check Diagnostics, LLC · 2005 · Recalled
- This deviceK142280 Healgen Oxazepam Test (Strip, Cassette, Cup, Dip Card), Healgen…Healgen Scientific,, LLC · 2014
- Descendant · cites it directly · 0 of its ownK163704 Healgen Multi-Drug Urine Test Cup; Healgen Multi-Drug Urine Test Dip…Healgen Scientific,, LLC · 2017
- Descendant · cites it directly · 0 of its ownK153597 Healgen Multi-Drug Urine Test Cup, Healgen Multi-Drug Urine Test Dip…Healgen Scientific,, LLC · 2016
- Descendant · cites it directly · 0 of its ownK151642 Heagen Multi-Drug Urine Test Cup, Healgen Multi-Drug Urine Test Dip…Healgen Scientific,, LLC · 2015
- Descendant · cites it directly · 0 of its ownK150356 Healgen Multi-Drug Urine Test Cup, Healgen Multi-Drug Urine Test Dip…Healgen Scientific,, LLC · 2015
Most influential descendants
Showing 4 of 4 · See all- K163704Healgen Multi-Drug Urine Test Cup; Healgen Multi-Drug Urine Test Dip CardHealgen Scientific,, LLC · 2017 · cites it directly0descendants
- K153597Healgen Multi-Drug Urine Test Cup, Healgen Multi-Drug Urine Test Dip CardHealgen Scientific,, LLC · 2016 · cites it directly0descendants
- K151642Heagen Multi-Drug Urine Test Cup, Healgen Multi-Drug Urine Test Dip CardHealgen Scientific,, LLC · 2015 · cites it directly0descendants
- K150356Healgen Multi-Drug Urine Test Cup, Healgen Multi-Drug Urine Test Dip CardHealgen Scientific,, LLC · 2015 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K050186 | Ameditech Immutest Multi-Drug Screen Panel Iii | Ameditech, Inc. | 2005 | 3 |
| −1 | K052115 | First Check Multi Drug Cup 12 for Marijuana (THC), Cocaine (Coc), Amphetamine… | First Check Diagnostics, LLC | 2005 | 86 |
| 0 (this device) | K142280 | Healgen Oxazepam Test (Strip, Cassette, Cup, Dip Card), Healgen Morphine Test… | Healgen Scientific,, LLC | 2014 | — |
| +1 | K163704 | Healgen Multi-Drug Urine Test Cup; Healgen Multi-Drug Urine Test Dip Card | Healgen Scientific,, LLC | 2017 | — |
| +1 | K153597 | Healgen Multi-Drug Urine Test Cup, Healgen Multi-Drug Urine Test Dip Card | Healgen Scientific,, LLC | 2016 | — |
| +1 | K151642 | Heagen Multi-Drug Urine Test Cup, Healgen Multi-Drug Urine Test Dip Card | Healgen Scientific,, LLC | 2015 | — |
| +1 | K150356 | Healgen Multi-Drug Urine Test Cup, Healgen Multi-Drug Urine Test Dip Card | Healgen Scientific,, LLC | 2015 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2015 | 2 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DJG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DJG device
- #1 K232659 Dochek® Multi-Drug Urine Test Cup Rx, Dochek®…score 17.6 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K052115 | First Check Multi Drug Cup 12 for Marijuana (THC), Cocaine (Coc), Amphetamine (Amp)…Summary page 4…21 CFR, 862.3170 Benzodiazepine Test System Toxicology DJG 21 CFR, 862.3650 Opiate Test System Toxicology 5. Predicate Devices: K052115 First Check Multi Drug Cup 12 6. Intended Use Healgen Oxazepam Test is an immunochromatographic assay for the qualitative… | 2005 |
What descends from it? (4)
4 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K163704 | Healgen Multi-Drug Urine Test Cup; Healgen Multi-Drug Urine Test Dip Card | 2017 | 0 |
| K153597 | Healgen Multi-Drug Urine Test Cup, Healgen Multi-Drug Urine Test Dip Card | 2016 | 0 |
| K151642 | Heagen Multi-Drug Urine Test Cup, Healgen Multi-Drug Urine Test Dip Card | 2015 | 0 |
| K150356 | Healgen Multi-Drug Urine Test Cup, Healgen Multi-Drug Urine Test Dip Card | 2015 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 9 years and passes through 3 companies; a new generation was cleared every 8.8 years on median.
- 2 of the 2 ancestors have a recall of any class.
- Of its descendants, K163704 (Healgen Scientific,, LLC, 2017) has gone furthest, with 0 descendants of its own.
- 12 other devices also cite its predicate K052115.
How does its category compare?
All DJG devicesDJG Enzyme Immunoassay, Opiates: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.
FDA decisions per year · DJG
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DJG
31in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DJG
2in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DJG
1in 2025
MAUDE reports naming product code DJG, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 0 |
| 2008 | 2 | — | 0 | 0 |
| 2009 | 2 | — | 0 | 0 |
| 2010 | 6 | 187 | 0 | 0 |
| 2011 | 6 | 233 | 1 | 4 |
| 2012 | 5 | 95 | 0 | 1 |
| 2013 | 5 | 60 | 0 | 4 |
| 2014 | 9 | 62 | 0 | 0 |
| 2015 | 12 | 141 | 0 | 3 |
| 2016 | 2 | — | 0 | 2 |
| 2017 | 4 | 101 | 0 | 1 |
| 2018 | 5 | 134 | 0 | 1 |
| 2019 | 3 | 235 | 1 | 0 |
| 2020 | 5 | 30 | 0 | 0 |
| 2021 | 3 | 422 | 0 | 2 |
| 2022 | 2 | — | 0 | 1 |
| 2023 | 10 | 140 | 0 | 0 |
| 2024 | 5 | 150 | 0 | 3 |
| 2025 | 3 | 31 | 2 | 1 |
| 2026 | 3 | 157 | 0 | — |
What is it indicated for?
Healgen Oxazepam Test is an immunochromatographic assay for the qualitative determination of Oxazepam (a drug in the benzodiazepine class) in human urine at a Cut-Off concentration of 300 ng/m L. The test is available in a Strip format, a Cassette format, a Dip Card format and a Cup format. The test may yield preliminary positive results even when prescription drug Oxazepam is ingested, at prescribed doses; it is not intended to distinguish between…
Read the full statement (274 words)
Healgen Oxazepam Test is an immunochromatographic assay for the qualitative determination of Oxazepam (a drug in the benzodiazepine class) in human urine at a Cut-Off concentration of 300 ng/m L. The test is available in a Strip format, a Cassette format, a Dip Card format and a Cup format.
The test may yield preliminary positive results even when prescription drug Oxazepam is ingested, at prescribed doses; it is not intended to distinguish between prescription use or abuse of this drug. There is no uniformly recognized cutoff concentration level for oxazepam in urine. The test provides only preliminary test results. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. GC/MS is the preferred confirmatory method. Clinical consideration and professional judgment should be exercised with any drug of abuse test result, particularly when the preliminary result is positive.
For in vitro diagnostic use only. It is intended for over-the-counter and for prescription use.
Healgen Morphine Test is an immunochromatographic assay for the qualitative determination of morphine (a drug in the opiate class) in human urine at a Cut-Off concentration of 2000 ng/mL. The test is available in a Strip format, a Cassette format, a Dip Card format and a Cup format.
The test provides only preliminary test results. A more specific alternative chemical method must be used in order to obtain a confirmed analytical result. GC/MS is the preferred confirmatory method. Clinical consideration and professional judgment should be exercised with any drug of abuse test result, particularly when the preliminary result is positive.
For in vitro diagnostic use only. It is intended for over-the-counter and for prescription use.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K142280 · printed Nov 5, 2026
Cite this page
510(k) Report. “K142280: Healgen Oxazepam Test (Strip, Cassette, Cup, Dip Card), Healgen Morphine Test (Strip, Cassette, Cup, Dip Card).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K142280
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026