Zimmer, Inc. · HRS Plate, Fixation, Bone
Cleared on Oct 22, 2014 as substantially equivalent to K111447 (Zimmer, Inc., 2011) and 2 other predicates after a 37-day review. Its family tree reaches back 5 generations to 1996. It has been recalled 2 times.
- Decided
- Oct 22, 2014
- Review
- 37 days
- Class
- Class II
- Product code
- HRS
- Recalls
- 2
- Predicates
- 3
Its longest line of descent runs back 5 generations to K962616 (1996). 11 ancestors in all. No later device cites it as a predicate yet.
- Root · 5 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
- 4 generations backK982732 Synthes (Usa) Distal Radius Plate System (DRPS)Synthes · 1998
- 3 generations backK040593 Periarticular Locking Plates and Screws, 2358, 2359 SeriesZimmer, Inc. · 2004 · Recalled
- 2 generations backK042598 Periarticular Locking Plates and Screws, 2357 and 2359 SeriesZimmer, Inc. · 2004 · Recalled
- 1 generation backK111447 Zimmer Periarticular ScrewsZimmer, Inc. · 2011 · Recalled
- This deviceK142579 Zimmer Periarticular Plating SystemZimmer, Inc. · 2014
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −5 | K962616 | Synthes Dorsal Distal Radius Plate (DDRP) System | Synthes (Usa) | 1996 | — |
| −4 | K982732 | Synthes (Usa) Distal Radius Plate System (DRPS) | Synthes | 1998 | — |
| −3 | K040593 | Periarticular Locking Plates and Screws, 2358, 2359 Series | Zimmer, Inc. | 2004 | 2 |
| −2 | K042598 | Periarticular Locking Plates and Screws, 2357 and 2359 Series | Zimmer, Inc. | 2004 | 1 |
| −1 | K111447 | Zimmer Periarticular Screws | Zimmer, Inc. | 2011 | 4 |
| 0 (this device) | K142579 | Zimmer Periarticular Plating System | Zimmer, Inc. | 2014 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1996 | 1 | 0 |
| 1998 | 1 | 0 |
| 2000 | 1 | 0 |
| 2001 | 1 | 0 |
| 2002 | 1 | 0 |
| 2004 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRS device
- #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K111447 | Zimmer Periarticular ScrewsSummary page 4…ation Fastener 21 CFR 888.3040 (HWC) Classification Panel: Orthopedics/87 Predicate Device(s): Zimmer Periarticular Plating System Screws (K111447) Synthes Distal Radius Plate System (K982732) Synthes Calcaneal Plate (K020401)… | 2011 |
| * | K982732 | Synthes (Usa) Distal Radius Plate System (DRPS)Summary page 4…ication Panel: Orthopedics/87 Predicate Device(s): Zimmer Periarticular Plating System Screws (K111447) Synthes Distal Radius Plate System (K982732) Synthes Calcaneal Plate (K020401) Purpose and Device The Zimmer Periarticular Plating System consi… | 1998 |
| * | K020401 | Synthes Calcaneal PlateSummary page 4…immer Periarticular Plating System Screws (K111447) Synthes Distal Radius Plate System (K982732) Synthes Calcaneal Plate (K020401) Purpose and Device The Zimmer Periarticular Plating System consists of Description: temporary implants (plates… | 2002 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Oct 10, 2019 | Class II | Z-0307-2020 | Packaging change control | Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). |
| Oct 10, 2019 | Class II | Z-0315-2020 | Packaging change control | Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 18 years and passes through 3 companies; a new generation was cleared every 3.0 years on median.
- 4 of the 11 ancestors have a recall of any class.
How does its category compare?
All HRS devicesHRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.
FDA decisions per year · HRS
54in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRS
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRS
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRS
2,306in 2025
MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 63 | 2 | 339 |
| 2008 | 35 | 87 | 11 | 311 |
| 2009 | 47 | 85 | 3 | 435 |
| 2010 | 49 | 100 | 16 | 491 |
| 2011 | 43 | 88 | 5 | 773 |
| 2012 | 59 | 106 | 4 | 1,663 |
| 2013 | 56 | 89 | 11 | 2,643 |
| 2014 | 76 | 57 | 0 | 2,413 |
| 2015 | 56 | 97 | 7 | 3,095 |
| 2016 | 44 | 109 | 5 | 2,276 |
| 2017 | 57 | 122 | 3 | 2,220 |
| 2018 | 40 | 116 | 2 | 2,663 |
| 2019 | 46 | 89 | 25 | 3,359 |
| 2020 | 48 | 88 | 1 | 2,790 |
| 2021 | 40 | 87 | 9 | 2,442 |
| 2022 | 47 | 144 | 3 | 1,700 |
| 2023 | 40 | 120 | 1 | 2,049 |
| 2024 | 54 | 96 | 0 | 1,849 |
| 2025 | 54 | 90 | 1 | 2,306 |
| 2026 | 51 | 82 | 3 | — |
What is it indicated for?
Periarticular Plating System Small Distal Volar Radial Radius and Small Distal Volar Ulnar Radius plates are indicated for temporary internal fixation and stabilization of fractures and osteotomies of the volar aspect of the distal radius, including associated carpal fusions.
Periarticular Plating System Calcaneal plates are indicated for complex extra-articular and intra-articular fractures and osteotomies of the calcaneus.
Periarticular Plating System screws are temporary internal fixation devices designed to stabilize fractures during the normal healing process.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K142579 · printed Nov 4, 2026
Cite this page
510(k) Report. “K142579: Zimmer Periarticular Plating System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K142579
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026