510(k) Report

510(k) · Cleared

Cleared

Ophthalmed Bending Laser Probes

K142830510(k) TraditionalCleared Jun 25, 2015268-day reviewClass II21 CFR 886.4390

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ophthalmed, LLC · HQF Laser, Ophthalmic

Cleared on Jun 25, 2015 as substantially equivalent to K021696 (Ophthalmed, LLC, 2002) and 3 other predicates after a 268-day review. Its family tree reaches back 4 generations to 1987. 2 later devices descend from it.

Decided
Jun 25, 2015
Review
268 days
Class
Class II
Product code
HQF
Recalls
None
Predicates
4

Its longest line of descent runs back 4 generations to K870942 (1987). 9 ancestors in all. 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2012: 1 other ancestor2002: 1 other ancestor2001: 1 other ancestor1995: 2 other ancestors2019: 1 descendant cleared2022: 1 descendant clearedK870942 · MVS Fiberoptic Lightpipe · Advanced Surgical Products, Inc. · 1987K982462 · Fiber Optic Endoillumination Probe · Microvision, Inc. · 1998K050807 · 20G Sma Laser Fiber, Model LF100 · Ophthalmed, LLC · 2005K121187 · Katalyst Laser Probes, Katalyst Illuminated Laser Probes · Katalyst Surgical, LLC · 20121990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 2 other ancestors2 generations back: 3 other ancestors 1 generation forward: 1 descendant2 generations forward: 1 descendant K121187 · Katalyst Laser Probes, Katalyst Illuminated Laser Probes · Katalyst Surgical, LLC · 2012K050807 · 20G Sma Laser Fiber, Model LF100 · Ophthalmed, LLC · 2005K982462 · Fiber Optic Endoillumination Probe · Microvision, Inc. · 1998K870942 · MVS Fiberoptic Lightpipe · Advanced Surgical Products, Inc. · 19870
  1. Root · 4 generations backK870942 MVS Fiberoptic LightpipeAdvanced Surgical Products, Inc. · 1987
  2. 3 generations backK982462 Fiber Optic Endoillumination ProbeMicrovision, Inc. · 1998
  3. 2 generations backK050807 20G Sma Laser Fiber, Model LF100Ophthalmed, LLC · 2005
  4. 1 generation backK121187 Katalyst Laser Probes, Katalyst Illuminated Laser ProbesKatalyst Surgical, LLC · 2012
  5. This deviceK142830 Ophthalmed Bending Laser ProbesOphthalmed, LLC · 2015
  6. Descendant · cites it directly · 1 of its ownK191846 MAXReach Laser ProbeVortex Surgical, Inc. · 2019
  7. Descendant · 2 generations on · 0 of its ownK220263 Vortex Surgical Laser Probes, Vortex Surgical Illuminated Laser…Vortex Surgical, Inc. · 2022 · Recalled

Most influential descendants

Showing 2 of 2 · See all
  • K191846MAXReach Laser ProbeVortex Surgical, Inc. · 2019 · cites it directly1descendant
  • K220263Vortex Surgical Laser Probes, Vortex Surgical Illuminated Laser Probes, Vortex Surgical…Vortex Surgical, Inc. · 2022 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K870942MVS Fiberoptic LightpipeAdvanced Surgical Products, Inc.1987—
−3K982462Fiber Optic Endoillumination ProbeMicrovision, Inc.1998—
−2K05080720G Sma Laser Fiber, Model LF100Ophthalmed, LLC2005—
−1K121187Katalyst Laser Probes, Katalyst Illuminated Laser ProbesKatalyst Surgical, LLC2012—
0 (this device)K142830Ophthalmed Bending Laser ProbesOphthalmed, LLC2015—
+1K191846MAXReach Laser ProbeVortex Surgical, Inc.2019—
+2K220263Vortex Surgical Laser Probes, Vortex Surgical Illuminated Laser Probes, Vortex…Vortex Surgical, Inc.20223

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199520
200110
200210
201210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
202210
FIG. 1 — Lineage of K142830, 1987–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HQF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HQF device

  1. #1 K251772 Navilas Laser System 577sl (156691)score 13.6 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K02169620G Sma Laser Fiber, Model LF20; 25G Sma Laser Fiber, Model LF25
Summary page 4
…gulatory class: II Product code: HQB III. PREDICATE DEVICE 510k number Trade or Proprietary or Model Name Manufacturer Primary predicate device K021696 LF20, LF25 OPHTHALMED LLC Yes K050807 LF100…
Ophthalmed, LLC2002—
*K05080720G Sma Laser Fiber, Model LF100
Summary page 4
…de or Proprietary or Model Name Manufacturer Primary predicate device K021696 LF20, LF25 OPHTHALMED LLC Yes K050807 LF100 OPHTHALMED LLC No K113857 Synergetics Directional Endo Ocular S…
Ophthalmed, LLC2005—
*K113857Synergetics Directional Endoocular Laser Probe
Summary page 4
…K021696 LF20, LF25 OPHTHALMED LLC Yes K050807 LF100 OPHTHALMED LLC No K113857 Synergetics Directional Endo Ocular SYNERGETICS No Laser Probe K121187 Katalyst l…
Synergetics, Inc.2012—
*K121187Katalyst Laser Probes, Katalyst Illuminated Laser Probes
Summary page 4
…OPHTHALMED LLC No K113857 Synergetics Directional Endo Ocular SYNERGETICS No Laser Probe K121187 Katalyst laser probes KATALYST SURGICAL No IV. DEVICE DESCRIPTION This laser probe is made out of 8ft…
Katalyst Surgical, LLC2012—

Also cleared against K021696: 3 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K191846MAXReach Laser ProbeVortex Surgical, Inc.20191

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 4 companies; a new generation was cleared every 7.0 years on median.
  • 1 of the 9 ancestors has a recall of any class.
  • Of its descendants, K191846 (Vortex Surgical, Inc., 2019) has gone furthest, with 1 descendant of its own.
  • 3 other devices also cite its predicate K021696.

How does its category compare?

All HQF devices

HQF Laser, Ophthalmic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · HQF

3in 2025

2007: 42008: 32009: 72010: 22011: 42012: 52013: 62014: 32015: 42016: 32017: 32018: 12019: 42020: 42021: 12022: 72023: 52024: 32025: 32026 (partial year): 2
2007high 7 (2009) · low 1 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HQF

264in 2025

2007: 198 days median2008: 28 days median2009: 115 days median2011: 128 days median2012: 179 days median2013: 225 days median2014: 215 days median2015: 295 days median2016: 271 days median2017: 189 days median2019: 107 days median2020: 53 days median2022: 86 days median2023: 155 days median2024: 167 days median2025: 264 days median
2007high 295 (2015) · low 28 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HQF

1in 2025

2007: 22008: 12009: 22010: 32011: 52012: 12013: 22014: 42025: 1
2007high 5 (2011) · low 0 (2015)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HQF

106in 2025

2007: 602008: 342009: 332010: 432011: 262012: 412013: 392014: 582015: 802016: 1082017: 772018: 822019: 662020: 722021: 1002022: 1112023: 922024: 752025: 106
2007high 111 (2022) · low 26 (2011)2025

MAUDE reports naming product code HQF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074198260
2008328134
20097115233
20102—343
20114128526
20125179141
20136225239
20143215458
20154295080
201632710108
20173189077
20181—082
20194107066
2020453072
20211—0100
20227860111
20235155092
20243167075
202532641106
20262—0—

What is it indicated for?

The Ophthalmed Bending Laser Probes (Models A207000, A807000, and A307000) are indicated for performing laser endophotocoagulation in the posterior segment of the eye during vitreoretinal surgery at an operating wavelength range from 500 to 1100 nm.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K142830: Ophthalmed Bending Laser Probes.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K142830

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026