510(k) · Cleared
ClearedEOGas 4 Ethylene Oxide Gas Sterilizer
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Andersen Sterilizers, Inc. · FLF Sterilizer, Ethylene-Oxide Gas
Cleared on Nov 18, 2015 as substantially equivalent to K812867 (3M Company, 1981) after a 251-day review. Its family tree reaches back 1 generation to 1981. 2 later devices descend from it.
- Decided
- Nov 18, 2015
- Review
- 251 days
- Class
- Class II
- Product code
- FLF
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K812867 (1981). 2 later devices descend from it, 2 citing it directly.
- Root · 1 generation backK812867 Steri-Vac #400C Gas Sterilizer3M Company · 1981 · Recalled
- This deviceK150646 EOGas 4 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc. · 2015
- Descendant · cites it directly · 0 of its ownK192978 EOGas 4 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc. · 2020
- Descendant · cites it directly · 0 of its ownK170432 Anprolene AN75 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc. · 2017
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K812867 | Steri-Vac #400C Gas Sterilizer | 3M Company | 1981 | 1 |
| 0 (this device) | K150646 | EOGas 4 Ethylene Oxide Gas Sterilizer | Andersen Sterilizers, Inc. | 2015 | — |
| +1 | K192978 | EOGas 4 Ethylene Oxide Gas Sterilizer | Andersen Sterilizers, Inc. | 2020 | — |
| +1 | K170432 | Anprolene AN75 Ethylene Oxide Gas Sterilizer | Andersen Sterilizers, Inc. | 2017 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2017 | 1 | 0 |
| 2020 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FLF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FLF device
- #1 K192978 EOGas 4 Ethylene Oxide Gas Sterilizerscore 0.6 · 2 generations · no Class I recall
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K812867 | Steri-Vac #400C Gas SterilizerSummary page 6…4 sterilizer 5.6 Predicate Device - Steri-Vac 4XL Device Name Steri-Vac™ 4XL Gas Sterilizer 510(k) number K812867 Manufacturer 3M™ Company The EOGas 4 Ethylene Oxide Sterilizer uses a flexible sterilization bag as a… | 1981 |
| * | — | Sterijet Ethylene Oxide Sterilization System Named without a submission number |
What descends from it? (2)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has a recall.
- Of its descendants, K192978 (Andersen Sterilizers, Inc., 2020) has gone furthest, with 0 descendants of its own.
How does its category compare?
All FLF devicesFLF Sterilizer, Ethylene-Oxide Gas: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.
FDA decisions per year · FLF
1in 2020
2026 to Oct 25, outlined.
Median 510(k) review, days · FLF
Too few FLF 510(k)s in any year since 2007 to give a median.
Recalls per year · FLF
2in 2014
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FLF
4in 2021
MAUDE reports naming product code FLF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 2 |
| 2008 | 0 | — | 0 | 1 |
| 2009 | 1 | — | 1 | 2 |
| 2010 | 0 | — | 0 | 3 |
| 2011 | 0 | — | 0 | 4 |
| 2012 | 0 | — | 1 | 5 |
| 2013 | 0 | — | 2 | 3 |
| 2014 | 0 | — | 2 | 6 |
| 2015 | 2 | — | 0 | 3 |
| 2016 | 0 | — | 0 | 3 |
| 2017 | 1 | — | 0 | 3 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 2 |
| 2020 | 1 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 4 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The EOGas 4 Ethylene Oxide Gas Sterilizer is intended for use in hospitals and other human healthcare settings. It is designed to sterilize reusable medical devices that are sensitive to moisture, heat, chemical corrosion, or radiation. The 3 hour cycle at 50°C in the EOGas 4 Ethylene Oxide Gas Sterilizer is for surface sterilization of medical devices as well as for the sterilization of single-lumen flexible endoscopes. The critical process parameters…
Read the full statement (342 words)
The EOGas 4 Ethylene Oxide Gas Sterilizer is intended for use in hospitals and other human healthcare settings. It is designed to sterilize reusable medical devices that are sensitive to moisture, heat, chemical corrosion, or radiation.
The 3 hour cycle at 50°C in the EOGas 4 Ethylene Oxide Gas Sterilizer is for surface sterilization of medical devices as well as for the sterilization of single-lumen flexible endoscopes. The critical process parameters for the cycle are summarized in Table 1.
Table 1. Critical parameters for the 3 hour cycle in the EOGas 4 Ethylene Oxide Gas Sterilizer
EO Amount: 17.6 g ± 5%; Temperature: 50°C ± 3°C; Relative Humidity: 35-70%; EO Exposure Time: 3 hours; Total Cycle Time: 3.5 hours
Maximum loads of specific materials and devices that have been validated are listed in Table 2. All validated maximum loads were processed without additional devices in the sterilizer.
Table 2. Load and material types validated in the EOGas 4 Ethylene Oxide Gas Sterilizer
Metal — Maximum load: 24 lbs (11 kg). Device examples: Surgical instruments, delicate sharps, including those with hinges and mated surfaces. Required aeration: Metal instruments do not absorb EO; follow pouch or wrap manufacturer’s instructions (Example: Tyvek® pouches and Sterisheet® wrap require ≥ 6 hours at 50°C).
Plastic — Maximum load: 7.0 lbs (3.2 kg). Device examples: Reusable power cords, trocars. Required aeration: 24 hours at 50°C; follow manufacturer’s instructions.
Fabric — Maximum load: 6.1 lbs (2.8 kg). Device examples: Reusable cloth gowns, towels. Required aeration: Follow manufacturer’s instructions.
Single-lumen Endoscope(s) — One (1) ≥ 2.0mm ID, ≤ 1100mm length; no additional devices. Device examples: Gastrovideoscopes, gastrointestinal videoscopes. Four (4) ≥ 1.2 mm ID, ≤ 700 mm length; no additional devices. Device examples: Bronchoscopes, bronchovideoscopes, cystoscopes, ureteroscopes, choledocoscopes. Required aeration: 12 hours at 50°C; follow manufacturer’s instructions.
Reusable medical devices must be aerated following the instructions of the device manufacturer and the packaging material manufacturer, then released for use after sterilization based on successful inactivation of an EZTest®- Gas Biological Indicator in the Andersen EOGas 4 SteriTest process challenge device.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K150646 · printed Nov 6, 2026
Cite this page
510(k) Report. “K150646: EOGas 4 Ethylene Oxide Gas Sterilizer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K150646
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026