510(k) Report

510(k) · Cleared

Cleared

EOGas 4 Ethylene Oxide Gas Sterilizer

K150646510(k) TraditionalCleared Nov 18, 2015251-day reviewClass II21 CFR 880.6860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Andersen Sterilizers, Inc. · FLF Sterilizer, Ethylene-Oxide Gas

Cleared on Nov 18, 2015 as substantially equivalent to K812867 (3M Company, 1981) after a 251-day review. Its family tree reaches back 1 generation to 1981. 2 later devices descend from it.

Decided
Nov 18, 2015
Review
251 days
Class
Class II
Product code
FLF
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K812867 (1981). 2 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2020: 1 descendant cleared2017: 1 descendant clearedK812867 · Steri-Vac #400C Gas Sterilizer · 3M Company · 1981 · recalled19801990200020102020
Descendants, by generation 1 generation forward: 2 descendants K812867 · Steri-Vac #400C Gas Sterilizer · 3M Company · 1981 · recalled0
  1. Root · 1 generation backK812867 Steri-Vac #400C Gas Sterilizer3M Company · 1981 · Recalled
  2. This deviceK150646 EOGas 4 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc. · 2015
  3. Descendant · cites it directly · 0 of its ownK192978 EOGas 4 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc. · 2020
  4. Descendant · cites it directly · 0 of its ownK170432 Anprolene AN75 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc. · 2017

Most influential descendants

Showing 2 of 2 · See all
  • K192978EOGas 4 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc. · 2020 · cites it directly0descendants
  • K170432Anprolene AN75 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc. · 2017 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K812867Steri-Vac #400C Gas Sterilizer3M Company19811
0 (this device)K150646EOGas 4 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc.2015—
+1K192978EOGas 4 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc.2020—
+1K170432Anprolene AN75 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc.2017—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
202010
FIG. 1 — Lineage of K150646, 1981–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FLF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FLF device

  1. #1 K192978 EOGas 4 Ethylene Oxide Gas Sterilizerscore 0.6 · 2 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K812867Steri-Vac #400C Gas Sterilizer
Summary page 6
…4 sterilizer 5.6 Predicate Device - Steri-Vac 4XL Device Name Steri-Vac™ 4XL Gas Sterilizer 510(k) number K812867 Manufacturer 3M™ Company The EOGas 4 Ethylene Oxide Sterilizer uses a flexible sterilization bag as a…
3M Company19811
*—Sterijet Ethylene Oxide Sterilization System
Named without a submission number
—

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K192978EOGas 4 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc.20200
K170432Anprolene AN75 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc.20170

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K192978 (Andersen Sterilizers, Inc., 2020) has gone furthest, with 0 descendants of its own.

How does its category compare?

All FLF devices

FLF Sterilizer, Ethylene-Oxide Gas: FDA decisions, review times, recalls and adverse event reports over 20 years. 2015, this device’s year, is highlighted.

FDA decisions per year · FLF

1in 2020

2009: 12015: 22017: 12020: 1
2007high 2 (2015) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FLF

Too few FLF 510(k)s in any year since 2007 to give a median.

Recalls per year · FLF

2in 2014

2009: 12012: 12013: 22014: 2
2007high 2 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FLF

4in 2021

2007: 22008: 12009: 22010: 32011: 42012: 52013: 32014: 62015: 32016: 32017: 32019: 22021: 4
2007high 6 (2014) · low 0 (2018)2025

MAUDE reports naming product code FLF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—02
20080—01
20091—12
20100—03
20110—04
20120—15
20130—23
20140—26
20152—03
20160—03
20171—03
20180—00
20190—02
20201—00
20210—04
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The EOGas 4 Ethylene Oxide Gas Sterilizer is intended for use in hospitals and other human healthcare settings. It is designed to sterilize reusable medical devices that are sensitive to moisture, heat, chemical corrosion, or radiation. The 3 hour cycle at 50°C in the EOGas 4 Ethylene Oxide Gas Sterilizer is for surface sterilization of medical devices as well as for the sterilization of single-lumen flexible endoscopes. The critical process parameters…

Read the full statement (342 words)

The EOGas 4 Ethylene Oxide Gas Sterilizer is intended for use in hospitals and other human healthcare settings. It is designed to sterilize reusable medical devices that are sensitive to moisture, heat, chemical corrosion, or radiation.

The 3 hour cycle at 50°C in the EOGas 4 Ethylene Oxide Gas Sterilizer is for surface sterilization of medical devices as well as for the sterilization of single-lumen flexible endoscopes. The critical process parameters for the cycle are summarized in Table 1.

Table 1. Critical parameters for the 3 hour cycle in the EOGas 4 Ethylene Oxide Gas Sterilizer

EO Amount: 17.6 g ± 5%; Temperature: 50°C ± 3°C; Relative Humidity: 35-70%; EO Exposure Time: 3 hours; Total Cycle Time: 3.5 hours

Maximum loads of specific materials and devices that have been validated are listed in Table 2. All validated maximum loads were processed without additional devices in the sterilizer.

Table 2. Load and material types validated in the EOGas 4 Ethylene Oxide Gas Sterilizer

Metal — Maximum load: 24 lbs (11 kg). Device examples: Surgical instruments, delicate sharps, including those with hinges and mated surfaces. Required aeration: Metal instruments do not absorb EO; follow pouch or wrap manufacturer’s instructions (Example: Tyvek® pouches and Sterisheet® wrap require ≥ 6 hours at 50°C).

Plastic — Maximum load: 7.0 lbs (3.2 kg). Device examples: Reusable power cords, trocars. Required aeration: 24 hours at 50°C; follow manufacturer’s instructions.

Fabric — Maximum load: 6.1 lbs (2.8 kg). Device examples: Reusable cloth gowns, towels. Required aeration: Follow manufacturer’s instructions.

Single-lumen Endoscope(s) — One (1) ≥ 2.0mm ID, ≤ 1100mm length; no additional devices. Device examples: Gastrovideoscopes, gastrointestinal videoscopes. Four (4) ≥ 1.2 mm ID, ≤ 700 mm length; no additional devices. Device examples: Bronchoscopes, bronchovideoscopes, cystoscopes, ureteroscopes, choledocoscopes. Required aeration: 12 hours at 50°C; follow manufacturer’s instructions.

Reusable medical devices must be aerated following the instructions of the device manufacturer and the packaging material manufacturer, then released for use after sterilization based on successful inactivation of an EZTest®- Gas Biological Indicator in the Andersen EOGas 4 SteriTest process challenge device.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K150646: EOGas 4 Ethylene Oxide Gas Sterilizer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K150646

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026