EOGas 4 Ethylene Oxide Gas Sterilizer

K192978510(k) TraditionalCleared Nov 12, 2020385-day reviewClass II21 CFR 880.6860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Andersen Sterilizers, Inc. · FLF Sterilizer, Ethylene-Oxide Gas

Cleared on Nov 12, 2020 as substantially equivalent to K150646 (Andersen Sterilizers, Inc., 2015) after a 385-day review. Its family tree reaches back 2 generations to 1981.

Decided
Nov 12, 2020
Review
385 days
Class
Class II
Product code
FLF
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K812867 (1981). No later device cites it as a predicate yet.

  1. Root · 2 generations backK812867 Steri-Vac #400C Gas Sterilizer3M Company · 1981 · Recalled
  2. 1 generation backK150646 EOGas 4 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc. · 2015
  3. This deviceK192978 EOGas 4 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc. · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K812867Steri-Vac #400C Gas Sterilizer3M Company19811
−1K150646EOGas 4 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc.2015—
0 (this device)K192978EOGas 4 Ethylene Oxide Gas SterilizerAndersen Sterilizers, Inc.2020—
FIG. 1 — Lineage of K192978, 1981–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FLF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K150646EOGas 4 Ethylene Oxide Gas Sterilizer
Summary page 6
…EPA #69340-7). Predicate Device Device Name EOGas 4 Ethylene Oxide Gas Sterilizer 510(k) number K150646 Manufacturer Andersen Sterilizers, Inc. The principles of operation for the EOGas 4 Ethylene…
Andersen Sterilizers, Inc.2015—
†K192980EOGas 4 Endo-SteriTestAndersen Sterilizers, Inc.2020—
†K930683Eztest-GasSgm Biomedical, Inc.1997—
†K191021Terragene Bionova, Terragene Bionova, Terragene Integron, Terragene Cintape, Terragene…Terragene S.A.20191
†K151585Andersen EOGas 4 SteriTestAndersen Sterilizers, Inc.2015—

Also cleared against K150646: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 39 years and passes through 2 companies; a new generation was cleared every 34.0 years on median.
  • 1 of the 2 ancestors has a recall of any class.
  • 1 other device also cites its predicate K150646.

How does its category compare?

All FLF devices

FLF Sterilizer, Ethylene-Oxide Gas: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · FLF

1in 2020

2009: 12015: 22017: 12020: 1
2007high 2 (2015) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FLF

Too few FLF 510(k)s in any year since 2007 to give a median.

Recalls per year · FLF

2in 2014

2009: 12012: 12013: 22014: 2
2007high 2 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FLF

4in 2021

2007: 22008: 12009: 22010: 32011: 42012: 52013: 32014: 62015: 32016: 32017: 32019: 22021: 4
2007high 6 (2014) · low 0 (2018)2025

MAUDE reports naming product code FLF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—02
20080—01
20091—12
20100—03
20110—04
20120—15
20130—23
20140—26
20152—03
20160—03
20171—03
20180—00
20190—02
20201—00
20210—04
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The EOGas 4 Ethylene Oxide Gas Sterilizer is designed to sterilize reusable medical devices that are sensitive to moisture, heat, chemical corrosion, or radiation. The critical process parameters for the two available cycles are summarized below: Table 1. EOGas 4 Ethylene Oxide Sterilizer cycle parameters EO Exposure Time: 3 hours; Total Cycle Time: 3.5 hours; EO Amount: 17.6 g + 5%; Temperature: 50°C +3°C; Relative Humidity: 35-70% EO Exposure Time: 6…

Read the full statement (240 words)

The EOGas 4 Ethylene Oxide Gas Sterilizer is designed to sterilize reusable medical devices that are sensitive to moisture, heat, chemical corrosion, or radiation. The critical process parameters for the two available cycles are summarized below:

Table 1. EOGas 4 Ethylene Oxide Sterilizer cycle parameters

EO Exposure Time: 3 hours; Total Cycle Time: 3.5 hours; EO Amount: 17.6 g + 5%; Temperature: 50°C +3°C; Relative Humidity: 35-70%

EO Exposure Time: 6 hours; Total Cycle Time: 7 hours

The differences between the two options are the length of EO gas exposure and the length of mandatory ventilation after gas exposure; the gas exposure is chosen based on the devices to be sterilized. The appropriate purge probe and process challenge device (PCD) must be used: EOGas 4 SteriTest for a 3-hour gas exposure, EOGas 4 Endo-SteriTest for a 6-hour gas exposure.

The EOGas 4 Ethylene Oxide Gas Sterilizer 3-hour gas exposure is used for surface sterilization of medical devices, including instruments with diffusion-restricted spaces (hinges or mated surfaces), as well as for the sterilization of endoscopes with working length shorter than 1100 mm as specified in the labeling. The EOGas 4 SteriTest PCD is used with the 3-hour gas exposure.

The EOGas 4 Ethylene Oxide Gas Sterilizer 6-hour gas exposure is used for sterilization of duodenoscopes and colonoscopes with working length longer than 1100 mm as specified in the labeling. The EOGas 4 Endo-SteriTest PCD is used with the 6-hour gas exposure.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K192978: EOGas 4 Ethylene Oxide Gas Sterilizer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K192978

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026