510(k) Report

510(k) · Cleared

Cleared

Sophono Bone Conduction Systems (S) Configuration and (M) Configuration

K153391510(k) TraditionalCleared Jun 16, 2016205-day reviewClass II21 CFR 874.3302

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sophono, Inc. · LXB Hearing Aid, Bone Conduction

Cleared on Jun 16, 2016 as substantially equivalent to K132189 (Sophono, Inc., 2013) and 1 other predicate after a 205-day review. Its family tree reaches back 9 generations to 1986. 1 later device descends from it.

Decided
Jun 16, 2016
Review
205 days
Class
Class II
Product code
LXB
Recalls
None
Predicates
2

Its longest line of descent runs back 9 generations to K861971 (1986). 24 ancestors in all, the oldest K855059 (1986). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2010: 1 other ancestor1986: 1 other ancestor2009: 1 other ancestor2008: 2 other ancestors2004: 1 other ancestor1999: 1 other ancestor1998: 1 other ancestor1994: 1 other ancestor1993: 1 other ancestor2002: 1 other ancestor2001: 1 other ancestor1991: 1 other ancestor1995: 1 other ancestor1987: 1 other ancestor2025: 1 descendant clearedK861971 · Xomed Audiant Bone Conductor W/Improved AA Coil · Xomed, Inc. · 1986K955713 · Nobelpharma Bone Anchored Hearing Aid · Nobelpharma USA, Inc. · 1996×2: 2 generations cleared close together, K984162 (1999), K992872 (1999) K080363 · Baha Cordelle II · Cochlear Bone Anchored Systems AB · 2008K090720 · Cochlear Baha BP100 · Cochlear Bone Anchored Systems AB · 2009K100193 · Otomag Bone Conduction Hearing System · Sophono, Inc. · 2010K102199 · Otomag Bone Conduction Hearing System Model Alpha 1 (S) and Alpha 1 (M) · Sophono, Inc. · 2011K132189 · Otomag Bone Conducation Hearing System · Sophono, Inc. · 20131990200020102020
  1. Root · 9 generations backK861971 Xomed Audiant Bone Conductor W/Improved AA CoilXomed, Inc. · 1986
  2. 5 generations between
  3. 3 generations backK100193 Otomag Bone Conduction Hearing SystemSophono, Inc. · 2010
  4. 2 generations backK102199 Otomag Bone Conduction Hearing System Model Alpha 1 (S) and Alpha 1…Sophono, Inc. · 2011
  5. 1 generation backK132189 Otomag Bone Conducation Hearing SystemSophono, Inc. · 2013
  6. This deviceK153391 Sophono Bone Conduction Systems (S) Configuration and (M)…Sophono, Inc. · 2016
  7. Descendant · cites it directly · 0 of its ownK243041 contact forte AlphaBhm-Tech Produktionsgesellschaft Mbh · 2025
Show all 9 generations
  1. Root · 9 generations backK861971 Xomed Audiant Bone Conductor W/Improved AA CoilXomed, Inc. · 1986
  2. 8 generations backK955713 Nobelpharma Bone Anchored Hearing AidNobelpharma USA, Inc. · 1996
  3. 7 generations backK984162 Branemark Bone-Anchored Hearing Aid (Baha) System for Pediatric UseNobelpharma USA, Inc. · 1999
  4. 6 generations backK992872 Branemark Bone-Anchored Hearing Aid (Baha) Cordelle IIEntific Medical Systems, Inc. · 1999
  5. 5 generations backK080363 Baha Cordelle IICochlear Bone Anchored Systems AB · 2008
  6. 4 generations backK090720 Cochlear Baha BP100Cochlear Bone Anchored Systems AB · 2009
  7. 3 generations backK100193 Otomag Bone Conduction Hearing SystemSophono, Inc. · 2010
  8. 2 generations backK102199 Otomag Bone Conduction Hearing System Model Alpha 1 (S) and Alpha 1…Sophono, Inc. · 2011
  9. 1 generation backK132189 Otomag Bone Conducation Hearing SystemSophono, Inc. · 2013
  10. This deviceK153391 Sophono Bone Conduction Systems (S) Configuration and (M)…Sophono, Inc. · 2016

Most influential descendants

Showing 1 of 1 · See all
  • K243041contact forte AlphaBhm-Tech Produktionsgesellschaft Mbh · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K861971Xomed Audiant Bone Conductor W/Improved AA CoilXomed, Inc.1986—
−8K955713Nobelpharma Bone Anchored Hearing AidNobelpharma USA, Inc.1996—
−7K984162Branemark Bone-Anchored Hearing Aid (Baha) System for Pediatric UseNobelpharma USA, Inc.1999—
−6K992872Branemark Bone-Anchored Hearing Aid (Baha) Cordelle IIEntific Medical Systems, Inc.1999—
−5K080363Baha Cordelle IICochlear Bone Anchored Systems AB2008—
−4K090720Cochlear Baha BP100Cochlear Bone Anchored Systems AB2009—
−3K100193Otomag Bone Conduction Hearing SystemSophono, Inc.2010—
−2K102199Otomag Bone Conduction Hearing System Model Alpha 1 (S) and Alpha 1 (M)Sophono, Inc.2011—
−1K132189Otomag Bone Conducation Hearing SystemSophono, Inc.2013—
0 (this device)K153391Sophono Bone Conduction Systems (S) Configuration and (M) ConfigurationSophono, Inc.2016—
+1K243041contact forte AlphaBhm-Tech Produktionsgesellschaft Mbh2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
198710
199110
199310
199410
199510
199810
199910
200110
200210
200410
200820
200910
201010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
FIG. 1 — Lineage of K153391, 1986–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LXB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LXB device

  1. #1 K254296 Ossiclear (Ossiclear System)score 14.7 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K132189Otomag Bone Conducation Hearing System
Summary page 4
…Sophono, Inc. 5744 Central Ave. #100 Boulder, CO 80301 510(k) #s: K132189 (including K100193, K102199, K123962) Sohono Bone Conduction System…
Sophono, Inc.2013—
*K100360BIA300 Series Implant and Abutment, BI300 Implant, BA300 Abutment
Summary page 5
…Cochlear Americas 13059 E. Peakview Ave. Centennial, CO 80111 510(k) #: K100360 Device Description The Sophono® Bone Conduction Hearing Systems are a family of sound processors and accessories that operate o…
Cochlear Americas2010—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K243041contact forte AlphaBhm-Tech Produktionsgesellschaft Mbh20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 5 companies; a new generation was cleared every 2.5 years on median.
  • None of the 24 ancestors has a recall.
  • Of its descendants, K243041 (Bhm-Tech Produktionsgesellschaft Mbh, 2025) has gone furthest, with 0 descendants of its own.

How does its category compare?

All LXB devices

LXB Hearing Aid, Bone Conduction: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · LXB

2in 2025

2008: 22009: 22010: 22011: 52012: 12013: 52015: 22016: 42017: 12018: 12019: 12021: 42025: 22026 (partial year): 4
2007high 5 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LXB

79in 2021

2011: 189 days median2013: 103 days median2016: 110 days median2021: 79 days median2026 (partial year): 164 days median
2007high 189 (2011) · low 79 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LXB

1in 2018

2012: 52018: 1
2007high 5 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LXB

261in 2025

2007: 42008: 1102009: 762010: 912011: 1232012: 3462013: 6402014: 5452015: 8242016: 6922017: 3792018: 3362019: 4972020: 5472021: 4902022: 3872023: 3482024: 2322025: 261
2007high 824 (2015) · low 4 (2007)2025

MAUDE reports naming product code LXB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—04
20082—0110
20092—076
20102—091
201151890123
20121—5346
201351030640
20140—0545
20152—0824
201641100692
20171—0379
20181—1336
20191—0497
20200—0547
20214790490
20220—0387
20230—0348
20240—0232
20252—0261
202641640—

What is it indicated for?

The Sophono® Sound Processor is intended for use with the Sophono® Headband (no age limitations), or with the Sophono® Magnetic Implant (patients 5 years of age and up) for the following patients and indications: Patients with conductive or mixed hearing losses, who can still benefit from amplification of sound. The pure tone average (PTA) bone conduction (BC) threshold for the indicated ear should be better than 45 dB HL (measured at 0.5, 1, 2, and 3…

Read the full statement (184 words)

The Sophono® Sound Processor is intended for use with the Sophono® Headband (no age limitations), or with the Sophono® Magnetic Implant (patients 5 years of age and up) for the following patients and indications:

Patients with conductive or mixed hearing losses, who can still benefit from amplification of sound. The pure tone average (PTA) bone conduction (BC) threshold for the indicated ear should be better than 45 dB HL (measured at 0.5, 1, 2, and 3 kHz).

Bilateral fitting is applicable for most patients having a symmetrically conductive or mixed hearing loss. The difference between the left and right sides’ BC thresholds should be less than 10 dB on average measured at 0.5, 1, 2, and 4 kHz, or less than 15 dB at individual frequencies.

Patients who have a profound sensorineural hearing loss in one ear and normal hearing in the opposite ear, who for some reason will not or cannot use an AC CROS. The pure tone average (PTA) air conduction (AC) threshold of the hearing ear should be better than 20 dB HL (measured at 0.5, 1, 2, and 3 kHz).

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K153391: Sophono Bone Conduction Systems (S) Configuration and (M) Configuration.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K153391

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026