510(k) Report

510(k) · Cleared

Cleared

Bone conduction Hearing Aid (BM100, BM300, BM310, SHOKZHEAR BM400, SHOKZ BM400MN, SHOKZHEAR BM410, SHOKZHEAR BM410MN, SHOKZHEAR BM420 and SHOKZHEAR BM420MN)

K253431510(k) TraditionalCleared Aug 19, 2026322-day reviewClass II21 CFR 874.3302

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Shokz Health Global Limited · LXB Hearing Aid, Bone Conduction

Cleared on Aug 19, 2026 as substantially equivalent to K161123 (Cochlear Americas, 2016) after a 322-day review. Its family tree reaches back 9 generations to 1986.

Decided
Aug 19, 2026
Review
322 days
Class
Class II
Product code
LXB
Recalls
None
Predicates
1

Its longest line of descent runs back 9 generations to K861971 (1986). 21 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 9 generations backK861971 Xomed Audiant Bone Conductor W/Improved AA CoilXomed, Inc. · 1986
  2. 5 generations between
  3. 3 generations backK132278 Cochlear Baha 4 Sound ProcessorCochlear Americas · 2013
  4. 2 generations backK142907 Baha 5 Sound ProcessorCochlear Americas · 2015 · Recalled
  5. 1 generation backK161123 Baha 5 Power Sound ProcessorCochlear Americas · 2016
  6. This deviceK253431 Bone conduction Hearing Aid (BM100, BM300, BM310, SHOKZHEAR BM400…Shokz Health Global Limited · 2026
Show all 9 generations
  1. Root · 9 generations backK861971 Xomed Audiant Bone Conductor W/Improved AA CoilXomed, Inc. · 1986
  2. 8 generations backK955713 Nobelpharma Bone Anchored Hearing AidNobelpharma USA, Inc. · 1996
  3. 7 generations backK984162 Branemark Bone-Anchored Hearing Aid (Baha) System for Pediatric UseNobelpharma USA, Inc. · 1999
  4. 6 generations backK992872 Branemark Bone-Anchored Hearing Aid (Baha) Cordelle IIEntific Medical Systems, Inc. · 1999
  5. 5 generations backK080363 Baha Cordelle IICochlear Bone Anchored Systems AB · 2008
  6. 4 generations backK090720 Cochlear Baha BP100Cochlear Bone Anchored Systems AB · 2009
  7. 3 generations backK132278 Cochlear Baha 4 Sound ProcessorCochlear Americas · 2013
  8. 2 generations backK142907 Baha 5 Sound ProcessorCochlear Americas · 2015 · Recalled
  9. 1 generation backK161123 Baha 5 Power Sound ProcessorCochlear Americas · 2016
  10. This deviceK253431 Bone conduction Hearing Aid (BM100, BM300, BM310, SHOKZHEAR BM400…Shokz Health Global Limited · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K861971Xomed Audiant Bone Conductor W/Improved AA CoilXomed, Inc.1986—
−8K955713Nobelpharma Bone Anchored Hearing AidNobelpharma USA, Inc.1996—
−7K984162Branemark Bone-Anchored Hearing Aid (Baha) System for Pediatric UseNobelpharma USA, Inc.1999—
−6K992872Branemark Bone-Anchored Hearing Aid (Baha) Cordelle IIEntific Medical Systems, Inc.1999—
−5K080363Baha Cordelle IICochlear Bone Anchored Systems AB2008—
−4K090720Cochlear Baha BP100Cochlear Bone Anchored Systems AB2009—
−3K132278Cochlear Baha 4 Sound ProcessorCochlear Americas2013—
−2K142907Baha 5 Sound ProcessorCochlear Americas20151
−1K161123Baha 5 Power Sound ProcessorCochlear Americas2016—
0 (this device)K253431Bone conduction Hearing Aid (BM100, BM300, BM310, SHOKZHEAR BM400, SHOKZ…Shokz Health Global Limited2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
199110
199310
199410
199510
199810
199910
200110
200210
200410
200810
201110
FIG. 1 — Lineage of K253431, 1986–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LXB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LXB device

  1. #1 K254296 Ossiclear (Ossiclear System)score 14.7 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K161123Baha 5 Power Sound Processor
Summary page 6
…evice Information Predicate device: Sponsor: Cochlear Americas Device: Baha 5 Power Sound Processor 510(K) Number: K161123 Reference device: Sponsor: Cochlear Americas Device: Cochlear Baha® SoundArc 510(…
Cochlear Americas2016—
†K171088Cochlear Baha SoundArcCochlear Americas2017—

Also cleared against K161123: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 40 years and passes through 6 companies; a new generation was cleared every 2.9 years on median.
  • 1 of the 21 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K161123.

How does its category compare?

All LXB devices

LXB Hearing Aid, Bone Conduction: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · LXB

2in 2025

2008: 22009: 22010: 22011: 52012: 12013: 52015: 22016: 42017: 12018: 12019: 12021: 42025: 22026 (partial year): 4
2007high 5 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LXB

79in 2021

2011: 189 days median2013: 103 days median2016: 110 days median2021: 79 days median2026 (partial year): 164 days median
2007high 189 (2011) · low 79 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LXB

1in 2018

2012: 52018: 1
2007high 5 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LXB

261in 2025

2007: 42008: 1102009: 762010: 912011: 1232012: 3462013: 6402014: 5452015: 8242016: 6922017: 3792018: 3362019: 4972020: 5472021: 4902022: 3872023: 3482024: 2322025: 261
2007high 824 (2015) · low 4 (2007)2025

MAUDE reports naming product code LXB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—04
20082—0110
20092—076
20102—091
201151890123
20121—5346
201351030640
20140—0545
20152—0824
201641100692
20171—0379
20181—1336
20191—0497
20200—0547
20214790490
20220—0387
20230—0348
20240—0232
20252—0261
202641640—

What is it indicated for?

The device is intended to treat patients with hearing loss via bone conduction. The device is non-invasive bone conduction hearing device which is retained on the patient’s head.

Indications:

1)Patients above 6 years old with conductive or mixed hearing loss. The pure tone average bone conduction hearing threshold (measured at 0.5, 1, 2, and 4kHz) should be better than or equal to 60 dB HL.

2)Patients 18 years and older with sensorineural hearing loss. The pure tone average bone conduction hearing threshold (measured at 0.5, 1, 2, and 4kHz) should be better than or equal to 60 dB HL.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K253431: Bone conduction Hearing Aid (BM100, BM300, BM310, SHOKZHEAR BM400, SHOKZ BM400MN, SHOKZHEAR BM410, SHOKZHEAR BM410MN, SHOKZHEAR BM420 and SHOKZHEAR BM420MN).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K253431

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026