510(k) Report

510(k) · Cleared

Cleared

Cydar EV

K160088510(k) TraditionalCleared Jul 7, 2016174-day reviewClass II21 CFR 892.1650

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cydar, Ltd. · OWB Interventional Fluoroscopic X-Ray System

Cleared on Jul 7, 2016 as substantially equivalent to K151598 (Philips Medical Systems Nederland B.V., 2015) after a 174-day review. Its family tree reaches back 7 generations to 1991. 7 later devices descend from it.

Decided
Jul 7, 2016
Review
174 days
Class
Class II
Product code
OWB
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K913770 (1991). 18 ancestors in all, the oldest K852353 (1985). 7 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 2 other ancestors1998: 2 other ancestors1985: 1 other ancestor2001: 1 other ancestor1997: 1 other ancestor1995: 1 other ancestor1993: 1 other ancestor1987: 1 other ancestor1994: 1 other ancestor2017: 1 descendant cleared2023: 1 descendant cleared2021: 2 descendants cleared2026: 1 descendant cleared2022: 1 descendant cleared2025: 1 descendant clearedK913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991K960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK052995 · Advantage Workstation 4.3. · GE Healthcare · 2005 · recalledK092639 · Innova Vision, Model S18751VN, Innova Trackvision, Model S18751VT, Innova Epvision, Model S18751EP · GE Medical Systems SCS · 2009K121772 · Allura 3D-RA Rel 6, 3D Roadmap Rel 1, MR-CT Roadmap Rel 1 · Philips Medical Systems Nederland B.V. · 2013K151598 · VesselNavigator Rel. 1.0 · Philips Medical Systems Nederland B.V. · 20151990200020102020
  1. Root · 7 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 6 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 5 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 4 generations backK052995 Advantage Workstation 4.3.GE Healthcare · 2005 · Recalled
  5. 3 generations backK092639 Innova Vision, Model S18751VN, Innova Trackvision, Model S18751VT…GE Medical Systems SCS · 2009
  6. 2 generations backK121772 Allura 3D-RA Rel 6, 3D Roadmap Rel 1, MR-CT Roadmap Rel 1Philips Medical Systems Nederland B.V. · 2013
  7. 1 generation backK151598 VesselNavigator Rel. 1.0Philips Medical Systems Nederland B.V. · 2015
  8. This deviceK160088 Cydar EVCydar, Ltd. · 2016
  9. Descendant · cites it directly · 3 of its ownK171829 EndoNautTherenva Sas · 2017
  10. Descendant · 2 generations on · 2 of its ownK212383 EndoNautTherenva Sas · 2021
  11. Descendant · 3 generations on · 1 of its ownK222070 EndoNautTherenva Sas · 2022
  12. Descendant · cites it directly · 1 of its ownK212442 Cydar EV (Series B) and Cydar EV MapsCydar, Ltd. · 2021
  13. Descendant · 2 generations on · 0 of its ownK252500 CARA SystemCara Medical, Ltd. · 2026

Showing 5 of 7 descendants. See all descendants

Descendants cleared per year

2017: 12021: 22022: 12023: 12025: 12026: 1
2017high 2 (2021) · low 0 (2018)2026

Most influential descendants

Showing 5 of 7 · See all
  • K171829EndoNautTherenva Sas · 2017 · cites it directly3descendants
  • K212383EndoNautTherenva Sas · 2021 · 2 generations on2descendants
  • K222070EndoNautTherenva Sas · 2022 · 3 generations on1descendant
  • K212442Cydar EV (Series B) and Cydar EV MapsCydar, Ltd. · 2021 · cites it directly1descendant
  • K252500CARA SystemCara Medical, Ltd. · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−6K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−5K020483Advantage Workstation 4.1GE Medical Systems20022
−4K052995Advantage Workstation 4.3.GE Healthcare20054
−3K092639Innova Vision, Model S18751VN, Innova Trackvision, Model S18751VT, Innova…GE Medical Systems SCS2009—
−2K121772Allura 3D-RA Rel 6, 3D Roadmap Rel 1, MR-CT Roadmap Rel 1Philips Medical Systems Nederland B.V.2013—
−1K151598VesselNavigator Rel. 1.0Philips Medical Systems Nederland B.V.2015—
0 (this device)K160088Cydar EVCydar, Ltd.2016—
+1K171829EndoNautTherenva Sas2017—
+2K212383EndoNautTherenva Sas2021—
+3K222070EndoNautTherenva Sas2022—
+1K212442Cydar EV (Series B) and Cydar EV MapsCydar, Ltd.2021—
+2K252500CARA SystemCara Medical, Ltd.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
198710
199310
199410
199510
199710
199820
200110
200420

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
202120
202210
202310
202510
202610
FIG. 1 — Lineage of K160088, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OWB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OWB device

  1. #1 K251602 Alphenix, INFX-8000V/B, INFX-8000V/S, V9.6…score 18.3 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K151598VesselNavigator Rel. 1.0
Summary page 5
…OWB, Interventional Fluoroscopic X-Ray System Device Class: Class II Classification Panel: Radiology 5. Legally Marketed Predicate Device K151598 – VesselNavigator – Philips Medical Systems Nederland B.V. 6. Device Description Cydar EV is a Software-as-a-Service product…
Philips Medical Systems Nederland B.V.2015—

What descends from it? (7)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K171829EndoNautTherenva Sas20173
K212442Cydar EV (Series B) and Cydar EV MapsCydar, Ltd.20211
K222998F3Acrew Imaging, Inc.20230

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 6 companies; a new generation was cleared every 3.7 years on median.
  • 6 of the 18 ancestors have a recall of any class.
  • Of its descendants, K171829 (Therenva Sas, 2017) has gone furthest, with 3 descendants of its own.

How does its category compare?

All OWB devices

OWB Interventional Fluoroscopic X-Ray System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · OWB

22in 2025

2007: 32008: 42009: 92010: 72011: 62012: 62013: 112014: 152015: 112016: 162017: 202018: 232019: 92020: 162021: 242022: 212023: 122024: 132025: 222026 (partial year): 15
2007high 24 (2021) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OWB

148in 2025

2007: 52 days median2008: 135 days median2009: 99 days median2010: 66 days median2011: 79 days median2012: 37 days median2013: 119 days median2014: 158 days median2015: 66 days median2016: 103 days median2017: 76 days median2018: 54 days median2019: 174 days median2020: 53 days median2021: 60 days median2022: 90 days median2023: 152 days median2024: 126 days median2025: 148 days median2026 (partial year): 221 days median
2007high 221 (2026) · low 37 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OWB

42so far in 2026, the most since 2007

2008: 12013: 102014: 92015: 352016: 132017: 132018: 62019: 72020: 82021: 312022: 242023: 222024: 112025: 302026 (partial year): 42
2007high 42 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OWB

14,008in 2025

2007: 12011: 12012: 12013: 272014: 1032015: 2,1342016: 4,0742017: 1,6042018: 1,4492019: 1,5582020: 1,5812021: 1,9812022: 2,9322023: 7,6042024: 7,9422025: 14,008
2007high 14,008 (2025) · low 0 (2008)2025

MAUDE reports naming product code OWB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735201
2008413510
200999900
201076600
201167901
201263701
2013111191027
2014151589103
20151166352,134
201616103134,074
20172076131,604
2018235461,449
2019917471,558
2020165381,581
20212460311,981
20222190242,932
202312152227,604
202413126117,942
2025221483014,008
20261522142—

What is it indicated for?

Cydar EV provides image guidance by overlaying preoperative 3D vessel anatomy, from a previously acquired contrast-enhanced, diagnostic CT scan, onto live fluoroscopic images in order to assist in the positioning of guidewires, catheters and other endovascular devices. Cydar EV is intended to assist fluoroscopy-guided endovascular procedures in the lower thorax, abdomen and pelvis. Suitable procedures include (but are not limited to) endovascular aortic…

Read the full statement (107 words)

Cydar EV provides image guidance by overlaying preoperative 3D vessel anatomy, from a previously acquired contrast-enhanced, diagnostic CT scan, onto live fluoroscopic images in order to assist in the positioning of guidewires, catheters and other endovascular devices.

Cydar EV is intended to assist fluoroscopy-guided endovascular procedures in the lower thorax, abdomen and pelvis. Suitable procedures include (but are not limited to) endovascular aortic aneurysm repair (AAA and mid-distal TAA), angioplasty, stenting and embolization in the common iliac, proximal external iliac and proximal internal iliac arteries and corresponding veins.

Cydar EV is not intended for use in the X-ray guided procedures in the liver, kidneys or pelvic organs.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K160088: Cydar EV.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K160088

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026