K171829510(k) TraditionalCleared Sep 21, 201793-day reviewClass II21 CFR 892.1650

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Therenva Sas · OWB Interventional Fluoroscopic X-Ray System

Cleared on Sep 21, 2017 as substantially equivalent to K160088 (Cydar, Ltd., 2016) after a 93-day review. Its family tree reaches back 8 generations to 1991. 3 later devices descend from it.

Decided
Sep 21, 2017
Review
93 days
Class
Class II
Product code
OWB
Recalls
None
Predicates
1

Its longest line of descent runs back 8 generations to K913770 (1991). 19 ancestors in all, the oldest K852353 (1985). 3 later devices descend from it, 1 citing it directly.

  1. Root · 8 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 7 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 6 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 5 generations backK052995 Advantage Workstation 4.3.GE Healthcare · 2005 · Recalled
  5. 4 generations backK092639 Innova Vision, Model S18751VN, Innova Trackvision, Model S18751VT…GE Medical Systems SCS · 2009
  6. 3 generations backK121772 Allura 3D-RA Rel 6, 3D Roadmap Rel 1, MR-CT Roadmap Rel 1Philips Medical Systems Nederland B.V. · 2013
  7. 2 generations backK151598 VesselNavigator Rel. 1.0Philips Medical Systems Nederland B.V. · 2015
  8. 1 generation backK160088 Cydar EVCydar, Ltd. · 2016
  9. This deviceK171829 EndoNautTherenva Sas · 2017
  10. Descendant · cites it directly · 2 of its ownK212383 EndoNautTherenva Sas · 2021
  11. Descendant · 2 generations on · 1 of its ownK222070 EndoNautTherenva Sas · 2022
  12. Descendant · 3 generations on · 0 of its ownK243432 Vascular Navigation PAD 2.0; Navigation Software Vascular PADBrainlab AG · 2025

Most influential descendants

Showing 3 of 3 · See all
  • K212383EndoNautTherenva Sas · 2021 · cites it directly2descendants
  • K222070EndoNautTherenva Sas · 2022 · 2 generations on1descendant
  • K243432Vascular Navigation PAD 2.0; Navigation Software Vascular PADBrainlab AG · 2025 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−7K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−6K020483Advantage Workstation 4.1GE Medical Systems20022
−5K052995Advantage Workstation 4.3.GE Healthcare20054
−4K092639Innova Vision, Model S18751VN, Innova Trackvision, Model S18751VT, Innova…GE Medical Systems SCS2009—
−3K121772Allura 3D-RA Rel 6, 3D Roadmap Rel 1, MR-CT Roadmap Rel 1Philips Medical Systems Nederland B.V.2013—
−2K151598VesselNavigator Rel. 1.0Philips Medical Systems Nederland B.V.2015—
−1K160088Cydar EVCydar, Ltd.2016—
0 (this device)K171829EndoNautTherenva Sas2017—
+1K212383EndoNautTherenva Sas2021—
+2K222070EndoNautTherenva Sas2022—
+3K243432Vascular Navigation PAD 2.0; Navigation Software Vascular PADBrainlab AG2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
198710
199310
199410
199510
199710
199820
200110
200420

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202110
202210
202510
FIG. 1 — Lineage of K171829, 1991–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OWB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OWB device

  1. #1 K251602 Alphenix, INFX-8000V/B, INFX-8000V/S, V9.6…score 18.2 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K160088Cydar EV
Summary page 4
…nal Fluoroscopic X-ray System Name: Regulation Number: 892.1650 510(k) Number: K160088 Device Name: Cydar EV Product Code: OWB, Interventional Fluoroscop…
Cydar, Ltd.2016—

Also cleared against K160088: 2 other devices →

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K212383EndoNautTherenva Sas20212

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 7 companies; a new generation was cleared every 3.7 years on median.
  • 6 of the 19 ancestors have a recall of any class.
  • Of its descendants, K212383 (Therenva Sas, 2021) has gone furthest, with 2 descendants of its own.
  • 2 other devices also cite its predicate K160088.

How does its category compare?

All OWB devices

OWB Interventional Fluoroscopic X-Ray System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · OWB

22in 2025

2007: 32008: 42009: 92010: 72011: 62012: 62013: 112014: 152015: 112016: 162017: 202018: 232019: 92020: 162021: 242022: 212023: 122024: 132025: 222026 (partial year): 15
2007high 24 (2021) · low 3 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OWB

148in 2025

2007: 52 days median2008: 135 days median2009: 99 days median2010: 66 days median2011: 79 days median2012: 37 days median2013: 119 days median2014: 158 days median2015: 66 days median2016: 103 days median2017: 76 days median2018: 54 days median2019: 174 days median2020: 53 days median2021: 60 days median2022: 90 days median2023: 152 days median2024: 126 days median2025: 148 days median2026 (partial year): 221 days median
2007high 221 (2026) · low 37 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OWB

42so far in 2026, the most since 2007

2008: 12013: 102014: 92015: 352016: 132017: 132018: 62019: 72020: 82021: 312022: 242023: 222024: 112025: 302026 (partial year): 42
2007high 42 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OWB

14,008in 2025

2007: 12011: 12012: 12013: 272014: 1032015: 2,1342016: 4,0742017: 1,6042018: 1,4492019: 1,5582020: 1,5812021: 1,9812022: 2,9322023: 7,6042024: 7,9422025: 14,008
2007high 14,008 (2025) · low 0 (2008)2025

MAUDE reports naming product code OWB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735201
2008413510
200999900
201076600
201167901
201263701
2013111191027
2014151589103
20151166352,134
201616103134,074
20172076131,604
2018235461,449
2019917471,558
2020165381,581
20212460311,981
20222190242,932
202312152227,604
202413126117,942
2025221483014,008
20261522142—

What is it indicated for?

EndoNaut provides image guidance by overlaying preoperative 3D vessel anatomy onto live fluoroscopic images in order to assist in the positioning of the guidewires, catheters and other endovascular devices.

EndoNaut is intended to assist endovascular procedures in the thorax, abdomen, neck, pelvis and lower limbs. Suitable procedures include (but not limited to) endovascular aortic aneurysm repair (AAA and TAA), angioplasty, stenting and embolization in iliac arteries and corresponding veins.

EndoNaut is not intended for use in the X-ray guided procedures in the liver, kidneys or pelvic organs.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K171829: EndoNaut.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K171829

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026