Torcon NB Advantage Catheters

K161822510(k) SpecialCleared Oct 27, 2016118-day reviewClass II21 CFR 870.1200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cook Incorporated · DQO Catheter, Intravascular, Diagnostic

Cleared on Oct 27, 2016 as substantially equivalent to K133130 (Cook, Inc., 2015) after a 118-day review. Its family tree reaches back 3 generations to 2001. 3 of the 7 devices in its family, counting itself, have a Class I recall.

Decided
Oct 27, 2016
Review
118 days
Class
Class II
Product code
DQO
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K011664 (2001). 6 ancestors in all, the oldest K882796 (1988). No later device cites it as a predicate yet. 3 of the 7 devices in this family, counting this one, have a Class I recall.

  1. Root · 3 generations backK011664 Imager II Angiographic CatheterBoston Scientific/Medi-Tech · 2001 · Recalled
  2. 2 generations backK121694 Imager II Angiographic CatheterBoston Scientific Corp · 2012 · Recalled (Class I)
  3. 1 generation backK133130 Beacon Tip Torcon NB Advantage Catheter, Torcon NB Advantage CatheterCook, Inc. · 2015 · Recalled (Class I)
  4. This deviceK161822 Torcon NB Advantage CathetersCook Incorporated · 2016

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K011664Imager II Angiographic CatheterBoston Scientific/Medi-Tech20012
−2K121694Imager II Angiographic CatheterBoston Scientific Corp2012Class I
−1K133130Beacon Tip Torcon NB Advantage Catheter, Torcon NB Advantage CatheterCook, Inc.2015Class I
0 (this device)K161822Torcon NB Advantage CathetersCook Incorporated2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810
200210
201211
FIG. 1 — Lineage of K161822, 2001–2016Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQO device

  1. #1 K254278 Arterial Pressure Monitoring Set/Trayscore 14.4 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K133130Beacon Tip Torcon NB Advantage Catheter, Torcon NB Advantage Catheter
Summary page 4
…ed’s Torcon NB® Advantage Catheters have an identical intended use to the predicate device, Beacon Tip Torcon NB® Advantage Catheters and Torcon NB® Advantage Catheters (K133130). Additionally, the principles of operation, technological characteristics, materials, and manufacturing processes of the Torcon…
Cook, Inc.2015Class I

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (3 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K133130Beacon Tip Torcon NB Advantage Catheter, Torcon NB Advantage CatheterCook, Inc. · 2015 · Direct predicate · ◆ on the line of descent in FIG. 11 Class I recall
  • K122937Slip-Cath Beacon Tip Catheter Model SCBR (Product Prefix), Shuttle Select Slip-Cath Catheter Model SCBR…Cook, Inc. · 2012 · 2 generations back · ◆ in the 2012 ancestors bar of FIG. 12 Class I recalls
  • K121694Imager II Angiographic CatheterBoston Scientific Corp · 2012 · 2 generations back · ◆ on the line of descent in FIG. 12 Class I recalls

What does this lineage say?

  • The line of descent spans 15 years and passes through 4 companies; a new generation was cleared every 2.3 years on median.
  • 5 of the 6 ancestors have a recall of any class; 3 have a Class I recall.

How does its category compare?

All DQO devices

DQO Catheter, Intravascular, Diagnostic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.

FDA decisions per year · DQO

2in 2025

2007: 82008: 32009: 82010: 72011: 62012: 152013: 22014: 32015: 102016: 42017: 102018: 102019: 62020: 32021: 12022: 42023: 42024: 42025: 22026 (partial year): 3
2007high 15 (2012) · low 1 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQO

148in 2024

2007: 106 days median2008: 80 days median2009: 58 days median2010: 137 days median2011: 74 days median2012: 94 days median2014: 109 days median2015: 209 days median2016: 89 days median2017: 176 days median2018: 234 days median2019: 113 days median2020: 30 days median2022: 181 days median2023: 73 days median2024: 148 days median2026 (partial year): 85 days median
2007high 234 (2018) · low 30 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQO

1in 2023

2007: 142008: 42009: 72010: 112011: 72012: 22013: 12015: 1, 1 Class I2016: 2, 1 Class I2017: 12018: 22019: 712020: 4, 4 Class I2022: 12023: 1, 1 Class I2026 (partial year): 24, 4 Class I
2007high 71 (2019) · low 0 (2014)2026

Class I (11 since 2007) Class II/III not classified

Adverse event reports per year · DQO

656in 2025

2007: 5642008: 7262009: 9332010: 5562011: 6252012: 5322013: 7532014: 6012015: 6282016: 6142017: 8732018: 7772019: 3862020: 3122021: 3382022: 3792023: 3912024: 5112025: 656
2007high 933 (2009) · low 312 (2020)2025

MAUDE reports naming product code DQO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007810614564
20083804726
20098587933
2010713711556
20116747625
201215942532
20132—1753
201431090601
2015102091 (1)628
20164892 (1)614
2017101761873
2018102342777
2019611371386
20203304 (4)312
20211—0338
202241811379
20234731 (1)391
202441480511
20252—0656
202638524 (4)—

What is it indicated for?

The Torcon NB® Advantage Catheters are intended for use in the peripheral and coronary vascular system including the carotid arteries in angiographic procedures by physicians trained and experienced in angiographic techniques. Standard techniques for placement of vascular access sheaths, angiographic catheters and wire guides should be employed.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K161822: Torcon NB Advantage Catheters.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K161822

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026