510(k) · Cleared
ClearedSysmex Automated Blood Coagulation Analyzer CS-5100
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Siemens Healthcare Diagnostics Products GmbH · JPA System, Multipurpose For In Vitro Coagulation Studies
Cleared on Dec 12, 2016 as substantially equivalent to K011235 (Dade Behring, Inc., 2001) and 3 other predicates after a 104-day review. Its family tree reaches back 4 generations to 1995.
- Decided
- Dec 12, 2016
- Review
- 104 days
- Class
- Class II
- Product code
- JPA
- Recalls
- None
- Predicates
- 4
Its longest line of descent runs back 4 generations to K926551 (1995). 10 ancestors in all, the oldest K894052 (1989). No later device cites it as a predicate yet.
- Root · 4 generations backK926551 Behring Fibrintimer aBehring Diagnostics, Inc. · 1995
- 3 generations backK955278 Behring Coagulation TimerBehring Diagnostics, Inc. · 1996
- 2 generations backK992321 Sysmex Automated Coagulation Analyzer, Model CA-6000Dade Behring, Inc. · 1999
- 1 generation backK993299 Sysmex Automated Coagulation Analyzer, Model CA-1500Dade Behring, Inc. · 1999
- This deviceK162420 Sysmex Automated Blood Coagulation Analyzer CS-5100Siemens Healthcare Diagnostics Products GmbH · 2016
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K926551 | Behring Fibrintimer a | Behring Diagnostics, Inc. | 1995 | — |
| −3 | K955278 | Behring Coagulation Timer | Behring Diagnostics, Inc. | 1996 | — |
| −2 | K992321 | Sysmex Automated Coagulation Analyzer, Model CA-6000 | Dade Behring, Inc. | 1999 | — |
| −1 | K993299 | Sysmex Automated Coagulation Analyzer, Model CA-1500 | Dade Behring, Inc. | 1999 | — |
| 0 (this device) | K162420 | Sysmex Automated Blood Coagulation Analyzer CS-5100 | Siemens Healthcare Diagnostics Products GmbH | 2016 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1989 | 1 | 0 |
| 1992 | 1 | 0 |
| 1997 | 1 | 0 |
| 2000 | 2 | 0 |
| 2001 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JPA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JPA device
- #1 K243858 TEG 6s Hemostasis System Citrated: K, KH, RT…score 12.0 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K011235 | Sysmex Automated Coagulation Analyzer / Model # CA-1500Summary page 5…5) Regulatory Class: Class II Product Code: JPA 510(k) Review Panel Hematology 3 Predicate Device Name of Device: Sysmex® CA-1500 (K011235) Common or Usual Name: Automated Coagulation Instrument Classification Name: Multipurpose system for in vitro coagulation st… | 2001 |
| * | K993299 | Sysmex Automated Coagulation Analyzer, Model CA-1500Summary page 6…application on predicate device Coagulation Factor V with Dade® Innovin® In vitro diagnostic reagent for the K993299 864.7290 Class II GJT Hematology determination of the activity of coagulation factor V in human plasma.… | 1999 |
| * | K000649 | Sysmex Automated Coagulation Analyzer, Model CA-1500Summary page 6…ion factor VII and coagulation factor X in human plasma by coagulometric methods. Protein C with Protein C Reagent Protein C Reagent is a coagulation test for the K000649 864.7290 Class II GGP Hematology quantitative determination of protein C activity in human plasma. Prot… | 2000 |
| * | K001645 | Sysmex Automated Coagulation Analyzer, Model CA-1500Summary page 6…ntitative determination of protein C activity in human plasma. Protein C with Berichrom® Protein C For the quantitative determination of functionally active K001645 864.7290 Class II GGP Hematology protein C using a chromogenic substrate as an aid in the diagnosis of i… | 2000 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 21 years and passes through 3 companies; a new generation was cleared every 3.3 years on median.
- None of the 10 ancestors has a recall.
- 7 other devices also cite its predicate K011235.
How does its category compare?
All JPA devicesJPA System, Multipurpose For In Vitro Coagulation Studies: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.
FDA decisions per year · JPA
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JPA
30in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JPA
1in 2020
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JPA
11in 2025
MAUDE reports naming product code JPA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 1 | 1,744 |
| 2008 | 2 | — | 0 | 918 |
| 2009 | 6 | 91 | 0 | 1,363 |
| 2010 | 1 | — | 6 | 727 |
| 2011 | 1 | — | 4 | 161 |
| 2012 | 0 | — | 1 | 52 |
| 2013 | 1 | — | 0 | 43 |
| 2014 | 0 | — | 0 | 48 |
| 2015 | 2 | — | 0 | 45 |
| 2016 | 6 | 114 | 3 | 6 |
| 2017 | 4 | 117 | 0 | 15 |
| 2018 | 1 | — | 0 | 39 |
| 2019 | 3 | 175 | 0 | 27 |
| 2020 | 0 | — | 1 | 18 |
| 2021 | 1 | — | 0 | 7 |
| 2022 | 1 | — | 0 | 9 |
| 2023 | 3 | 506 | 0 | 11 |
| 2024 | 1 | — | 0 | 8 |
| 2025 | 3 | 30 | 0 | 11 |
| 2026 | 1 | — | 1 | — |
What is it indicated for?
Sysmex® CS-5100: The Sysmex® CS-5100 is a fully automated blood coagulation analyzer intended for in vitro diagnostic use using plasma collected from venous blood samples in 3.2% sodium citrate tubes to analyze clotting, chromogenic and immunoassay methods in the clinical laboratory. For determination of: • Prothrombin Time (PT) seconds and PT INR with Dade® Innovin® • Activated Partial Thromboplastin Time (APTT) with Dade® Actin® FSL • Fibrinogen (Fbg)…
Read the full statement (232 words)
Sysmex® CS-5100:
The Sysmex® CS-5100 is a fully automated blood coagulation analyzer intended for in vitro diagnostic use using plasma collected from venous blood samples in 3.2% sodium citrate tubes to analyze clotting, chromogenic and immunoassay methods in the clinical laboratory.
For determination of:
• Prothrombin Time (PT) seconds and PT INR with Dade® Innovin®
• Activated Partial Thromboplastin Time (APTT) with Dade® Actin® FSL
• Fibrinogen (Fbg) with Dade® Thrombin Reagent
• Coagulation Factor V with Dade® Innovin®
• Coagulation Factor VII with Dade® Innovin®
• Protein C with Protein C Reagent
• Antithrombin (AT) with INNOVANCE® Antithrombin
• Protein C with Berichrom® Protein C
• D-dimer with INNOVANCE® D-Dimer
The performance of this device has not been established in neonate and pediatric patient populations.
Coagulation Factor V Deficient Plasma:
In vitro diagnostic reagent for the determination of the activity of coagulation factor V in human plasma.
Coagulation Factor II, VII and X Deficient Plasmas:
In vitro diagnostic reagents for the determination of the activity of coagulation factor II (prothrombin), coagulation factor VII and coagulation factor X in human plasma by coagulometric methods.
Protein C Reagent:
Protein C Reagent is a coagulation test for the quantitative determination of protein C activity in human plasma.
Berichrom® Protein C:
For the quantitative determination of functionally active protein C using a chromogenic substrate as an aid in the diagnosis of inherited and acquired deficiencies.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K162420 · printed Nov 6, 2026
Cite this page
510(k) Report. “K162420: Sysmex Automated Blood Coagulation Analyzer CS-5100.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K162420
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026