GC85A

K172229510(k) TraditionalCleared Nov 22, 2017120-day reviewClass II21 CFR 892.1680

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Samsung Electronics Co., Ltd. · KPR System, X-Ray, Stationary

Cleared on Nov 22, 2017 as substantially equivalent to K160997 (Samsung Electronics Co., Ltd., 2016) after a 120-day review. Its family tree reaches back 12 generations to 1998. 21 later devices descend from it.

Decided
Nov 22, 2017
Review
120 days
Class
Class II
Product code
KPR
Recalls
None
Predicates
1

Its longest line of descent runs back 12 generations to K981556 (1998). 30 ancestors in all, the oldest K862120 (1986). 21 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2015: 2 other ancestors2014: 1 other ancestor2009: 2 other ancestors2013: 1 other ancestor2005: 1 other ancestor2010: 1 other ancestor2002: 2 other ancestors2001: 1 other ancestor2004: 1 other ancestor1999: 1 other ancestor2008: 1 other ancestor1998: 1 other ancestor1988: 1 other ancestor2003: 1 other ancestor1986: 1 other ancestor2018: 7 descendants cleared2024: 4 descendants cleared2026: 2 descendants cleared2019: 1 descendant cleared2022: 2 descendants cleared2021: 2 descendants cleared2020: 1 descendant cleared2023: 1 descendant cleared2025: 1 descendant clearedK981556 · Canon X-Ray Digital Camera Cxdi-11 · Canon USA, Inc. · 1998K992547 · Canon X-Ray Digital Camera, Model Cxdi-22 · Canon USA, Inc. · 1999K023750 · Cannon Digital Radiography Model Cxdi-40G · Canon USA, Inc. · 2002K031447 · Canon, Digital Radiography, Model Cxdi-50G · Canon, Inc. · 2003K060433 · Digital Radiography Cxdi-50C · Canon, Inc. · 2006K091545 · Digital Radiography Cxdi-60C · Canon, Inc. · 2009K102012 · Digital Radiography · Canon Inc. -Medical Equipment Group · 2010 · recalled×2: 2 generations cleared close together, K103596 (2011), K111548 (2011) K132509 · FDR D-Evo Flat Panel Detector System · Fujifilm Medical Systems U.S.A, Inc. · 2013K141765 · FDR D-Evo Flat Panel Detector System · Fujifilm Medical Systems U.S.A, Inc. · 2014K160997 · GC85A · Samsung Electronics Co., Ltd. · 20161990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 2 other ancestors3 generations back: 2 other ancestors4 generations back: 3 other ancestors5 generations back: 3 other ancestors6 generations back: 3 other ancestors7 generations back: 3 other ancestors8 generations back: 2 other ancestors 1 generation forward: 2 descendants2 generations forward: 7 descendants3 generations forward: 3 descendants4 generations forward: 3 descendants5 generations forward: 3 descendants6 generations forward: 3 descendants K160997 · GC85A · Samsung Electronics Co., Ltd. · 2016K141765 · FDR D-Evo Flat Panel Detector System · Fujifilm Medical Systems U.S.A, Inc. · 2014K132509 · FDR D-Evo Flat Panel Detector System · Fujifilm Medical Systems U.S.A, Inc. · 2013K111548 · Wireless/Wired FDR D-Evo Flat Pancel Detector System Model DR-ID600 W/DR-ID611SE · Fujifilm Medical System U.S.A., Inc. · 2011K103596 · Wireless/Wired FDR D-Evo Flat Panel Detector · Fujifilm Medical Systems U.S.A, Inc. · 2011K102012 · Digital Radiography · Canon Inc. -Medical Equipment Group · 2010 · recalledK091545 · Digital Radiography Cxdi-60C · Canon, Inc. · 2009K060433 · Digital Radiography Cxdi-50C · Canon, Inc. · 2006K031447 · Canon, Digital Radiography, Model Cxdi-50G · Canon, Inc. · 2003K023750 · Cannon Digital Radiography Model Cxdi-40G · Canon USA, Inc. · 2002K992547 · Canon X-Ray Digital Camera, Model Cxdi-22 · Canon USA, Inc. · 1999K981556 · Canon X-Ray Digital Camera Cxdi-11 · Canon USA, Inc. · 1998−10−50+5
  1. Root · 12 generations backK981556 Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc. · 1998
  2. 8 generations between
  3. 3 generations backK132509 FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2013
  4. 2 generations backK141765 FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2014
  5. 1 generation backK160997 GC85ASamsung Electronics Co., Ltd. · 2016
  6. This deviceK172229 GC85ASamsung Electronics Co., Ltd. · 2017
  7. Descendant · cites it directly · 18 of its ownK180543 GC70, GU60A&GU60A-65, GF50, GF50A, GR40CW, and GM85Samsung Electronics Co., Ltd. · 2018
  8. Descendant · 2 generations on · 10 of its ownK181626 Digital Diagnostic Mobile X-ray SystemSamsung Electronics Co., Ltd. · 2018
  9. Descendant · cites it directly · 5 of its ownK181629 GC85ASamsung Electronics Co., Ltd. · 2018
  10. Descendant · 2 generations on · 5 of its ownK181631 GR40CWSamsung Electronics Co., Ltd. · 2018
  11. Descendant · 3 generations on · 4 of its ownK183292 Topaz Mobile DR SystemDRGEM Corporation · 2019
Show all 12 generations
  1. Root · 12 generations backK981556 Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc. · 1998
  2. 11 generations backK992547 Canon X-Ray Digital Camera, Model Cxdi-22Canon USA, Inc. · 1999
  3. 10 generations backK023750 Cannon Digital Radiography Model Cxdi-40GCanon USA, Inc. · 2002
  4. 9 generations backK031447 Canon, Digital Radiography, Model Cxdi-50GCanon, Inc. · 2003
  5. 8 generations backK060433 Digital Radiography Cxdi-50CCanon, Inc. · 2006
  6. 7 generations backK091545 Digital Radiography Cxdi-60CCanon, Inc. · 2009
  7. 6 generations backK102012 Digital RadiographyCanon Inc. -Medical Equipment Group · 2010 · Recalled
  8. 5 generations backK103596 Wireless/Wired FDR D-Evo Flat Panel DetectorFujifilm Medical Systems U.S.A, Inc. · 2011
  9. 4 generations backK111548 Wireless/Wired FDR D-Evo Flat Pancel Detector System Model DR-ID600…Fujifilm Medical System U.S.A., Inc. · 2011
  10. 3 generations backK132509 FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2013
  11. 2 generations backK141765 FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2014
  12. 1 generation backK160997 GC85ASamsung Electronics Co., Ltd. · 2016
  13. This deviceK172229 GC85ASamsung Electronics Co., Ltd. · 2017

Showing 5 of 21 descendants. See all descendants

Descendants cleared per year

2018: 72019: 12020: 12021: 22022: 22023: 12024: 42025: 12026: 2
2018high 7 (2018) · low 1 (2019)2026

Most influential descendants

Showing 5 of 21 · See all
  • K180543GC70, GU60A&GU60A-65, GF50, GF50A, GR40CW, and GM85Samsung Electronics Co., Ltd. · 2018 · cites it directly18descendants
  • K181626Digital Diagnostic Mobile X-ray SystemSamsung Electronics Co., Ltd. · 2018 · 2 generations on10descendants
  • K181629GC85ASamsung Electronics Co., Ltd. · 2018 · cites it directly5descendants
  • K181631GR40CWSamsung Electronics Co., Ltd. · 2018 · 2 generations on5descendants
  • K183292Topaz Mobile DR SystemDRGEM Corporation · 2019 · 3 generations on4descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−12K981556Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc.1998—
−11K992547Canon X-Ray Digital Camera, Model Cxdi-22Canon USA, Inc.1999—
−10K023750Cannon Digital Radiography Model Cxdi-40GCanon USA, Inc.2002—
−9K031447Canon, Digital Radiography, Model Cxdi-50GCanon, Inc.2003—
−8K060433Digital Radiography Cxdi-50CCanon, Inc.2006—
−7K091545Digital Radiography Cxdi-60CCanon, Inc.2009—
−6K102012Digital RadiographyCanon Inc. -Medical Equipment Group20101
−5K103596Wireless/Wired FDR D-Evo Flat Panel DetectorFujifilm Medical Systems U.S.A, Inc.2011—
−4K111548Wireless/Wired FDR D-Evo Flat Pancel Detector System Model DR-ID600 W/DR-ID611SEFujifilm Medical System U.S.A., Inc.2011—
−3K132509FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc.2013—
−2K141765FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc.2014—
−1K160997GC85ASamsung Electronics Co., Ltd.2016—
0 (this device)K172229GC85ASamsung Electronics Co., Ltd.2017—
+1K180543GC70, GU60A&GU60A-65, GF50, GF50A, GR40CW, and GM85Samsung Electronics Co., Ltd.2018—
+2K181626Digital Diagnostic Mobile X-ray SystemSamsung Electronics Co., Ltd.2018—
+1K181629GC85ASamsung Electronics Co., Ltd.2018—
+2K181631GR40CWSamsung Electronics Co., Ltd.2018—
+3K183292Topaz Mobile DR SystemDRGEM Corporation2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
198810
199810
199910
200110
200220
200310
200410
200510
200810
200920
201010
201310
201410
201520

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201870
201910
202010
202120
202220
202310
202440
202510
202620
FIG. 1 — Lineage of K172229, 1998–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KPR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KPR device

  1. #1 K242119 Innovision-Exiiscore 17.0 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K160997GC85A
Summary page 4
…GC85A Classification Stationary X-ray Name System Product Code KPR Regulation 21 CFR 892.1680 510(K)# K160997 510(K) July 6, 2016 Decision Date 1 ===…
Samsung Electronics Co., Ltd.2016—

Also cleared against K160997: 2 other devices →

What descends from it? (21)

See all 21

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K180543GC70, GU60A&GU60A-65, GF50, GF50A, GR40CW, and GM85Samsung Electronics Co., Ltd.201818
K181629GC85ASamsung Electronics Co., Ltd.20185

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 19 years and passes through 6 companies; a new generation was cleared every 1.4 years on median.
  • 9 of the 30 ancestors have a recall of any class.
  • Of its descendants, K180543 (Samsung Electronics Co., Ltd., 2018) has gone furthest, with 18 descendants of its own.
  • 2 other devices also cite its predicate K160997.

How does its category compare?

All KPR devices

KPR System, X-Ray, Stationary: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · KPR

8in 2025

2007: 122008: 152009: 92010: 92011: 92012: 112013: 52014: 102015: 182016: 112017: 62018: 152019: 122020: 162021: 62022: 82023: 92024: 112025: 82026 (partial year): 6
2007high 18 (2015) · low 5 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KPR

155in 2025

2007: 31 days median2008: 48 days median2009: 35 days median2010: 126 days median2011: 152 days median2012: 58 days median2013: 163 days median2014: 108 days median2015: 81 days median2016: 84 days median2017: 75 days median2018: 30 days median2019: 33 days median2020: 39 days median2021: 55 days median2022: 43 days median2023: 76 days median2024: 162 days median2025: 155 days median2026 (partial year): 197 days median
2007high 197 (2026) · low 30 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KPR

7in 2025

2007: 102008: 102009: 52010: 32011: 52012: 12013: 52014: 82015: 12016: 42017: 32018: 42019: 12020: 12022: 22023: 42024: 12025: 7
2007high 10 (2007) · low 0 (2021)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KPR

39in 2025

2007: 1202008: 952009: 612010: 822011: 1032012: 742013: 242014: 342015: 592016: 182017: 312018: 362019: 772020: 412021: 372022: 272023: 392024: 342025: 39
2007high 120 (2007) · low 18 (2016)2025

MAUDE reports naming product code KPR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007123110120
200815481095
2009935561
20109126382
201191525103
20121158174
20135163524
201410108834
20151881159
20161184418
2017675331
20181530436
20191233177
20201639141
2021655037
2022843227
2023976439
202411162134
20258155739
202661970—

What is it indicated for?

The GC85A Digital X-ray Imaging System is intended for use in generating radiographic images of human anatomy by a qualified/trained doctor or technician. This device is not intended for mammographic applications.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K172229: GC85A.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K172229

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026