510(k) Report

510(k) · Cleared

Cleared

EndoWrist Stapler 45 Instrument, EndoWrist Stapler 45 Reloads, EndoWrist Stapler 30 Instrument, EndoWrist Stapler 30 Reloads

K170508510(k) TraditionalCleared Mar 10, 201717-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Intuitive Surgical, Inc. · NAY System, Surgical, Computer Controlled Instrument

Cleared on Mar 10, 2017 as substantially equivalent to K140553 (Intuitive Surgical, Inc., 2014) and 1 other predicate after a 17-day review. Its family tree reaches back 2 generations to 2003. 3 of the 16 devices in its family, counting itself, have a Class I recall. 12 later devices descend from it.

Decided
Mar 10, 2017
Review
17 days
Class
Class II
Product code
NAY
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K033269 (2003). 3 ancestors in all. 12 later devices descend from it, 4 citing it directly. 3 of the 16 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2014: 1 other ancestor2023: 2 descendants cleared, 1 with a Class I recall12018: 2 descendants cleared2019: 2 descendants cleared2021: 1 descendant cleared, 1 with a Class I recall12025: 1 descendant cleared2024: 2 descendants cleared, 1 with a Class I recall12026: 2 descendants clearedK033269 · Endopath Endocutter Gray Cartridge, Model 6R45M/Gray Cartridge Reload · Ethicon Endo-Surgery, Inc. · 2003K152421 · IS4000 Stapler 30 Instrument and Stapler 30 Reloads · Intuitive Surgical, Inc. · 2016 · recalled200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 4 descendants, 1 with a Class I recall12 generations forward: 5 descendants, 2 with a Class I recall23 generations forward: 1 descendant4 generations forward: 1 descendant5 generations forward: 1 descendant K152421 · IS4000 Stapler 30 Instrument and Stapler 30 Reloads · Intuitive Surgical, Inc. · 2016 · recalledK033269 · Endopath Endocutter Gray Cartridge, Model 6R45M/Gray Cartridge Reload · Ethicon Endo-Surgery, Inc. · 20030+5
  1. Root · 2 generations backK033269 Endopath Endocutter Gray Cartridge, Model 6R45M/Gray Cartridge ReloadEthicon Endo-Surgery, Inc. · 2003
  2. 1 generation backK152421 IS4000 Stapler 30 Instrument and Stapler 30 ReloadsIntuitive Surgical, Inc. · 2016 · Recalled
  3. This deviceK170508 EndoWrist Stapler 45 Instrument, EndoWrist Stapler 45 Reloads…Intuitive Surgical, Inc. · 2017
  4. Descendant · cites it directly · 6 of its ownK173721 SureForm 60 and SureForm 60 ReloadsIntuitive Surgical · 2018 · Recalled
  5. Descendant · 2 generations on · 5 of its ownK183224 SureForm 45, SureForm 45 ReloadsIntuitive Surgical · 2019 · Recalled
  6. Descendant · cites it directly · 4 of its ownK190999 SureForm 45 Curved Tip, SureForm 45 Gray ReloadIntuitive Surgical, Inc. · 2019 · Recalled
  7. Descendant · cites it directly · 4 of its ownK181395 Universal Cannula Seal (5-12 mm)Intuitive Surgical, Inc. · 2018
  8. Descendant · 2 generations on · 3 of its ownK231358 Universal Seal (5-12 mm)Intuitive Surgical, Inc. · 2023

Showing 5 of 12 descendants. See all descendants

Descendants cleared per year

2018: 22019: 22021: 12023: 22024: 22025: 12026: 2
2018high 2 (2018) · low 0 (2020)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 12 · See all
  • K173721SureForm 60 and SureForm 60 ReloadsIntuitive Surgical · 2018 · cites it directly6descendants
  • K183224SureForm 45, SureForm 45 ReloadsIntuitive Surgical · 2019 · 2 generations on5descendants
  • K190999SureForm 45 Curved Tip, SureForm 45 Gray ReloadIntuitive Surgical, Inc. · 2019 · cites it directly4descendants
  • K181395Universal Cannula Seal (5-12 mm)Intuitive Surgical, Inc. · 2018 · cites it directly4descendants
  • K231358Universal Seal (5-12 mm)Intuitive Surgical, Inc. · 2023 · 2 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K033269Endopath Endocutter Gray Cartridge, Model 6R45M/Gray Cartridge ReloadEthicon Endo-Surgery, Inc.2003—
−1K152421IS4000 Stapler 30 Instrument and Stapler 30 ReloadsIntuitive Surgical, Inc.20163
0 (this device)K170508EndoWrist Stapler 45 Instrument, EndoWrist Stapler 45 Reloads, EndoWrist…Intuitive Surgical, Inc.2017—
+1K173721SureForm 60 and SureForm 60 ReloadsIntuitive Surgical20183
+2K183224SureForm 45, SureForm 45 ReloadsIntuitive Surgical20191
+1K190999SureForm 45 Curved Tip, SureForm 45 Gray ReloadIntuitive Surgical, Inc.20191
+1K181395Universal Cannula Seal (5-12 mm)Intuitive Surgical, Inc.2018—
+2K231358Universal Seal (5-12 mm)Intuitive Surgical, Inc.2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201820
201920
202111
202321
202421
202510
202620
FIG. 1 — Lineage of K170508, 2003–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NAY device

  1. #1 K232610 da Vinci Surgical System Model IS5000, da…score 32.9 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K140553Endowrist Stapler 45 and Stapler 45 Reloads
Summary page 4
…NAY GDW Classification Advisory Committee: General and Plastic Surgery Predicate Device: K140553 – EndoWrist Stapler 45 and Stapler 45 Reloads K152421 – Endowrist Stapler 30 Instrument and Sta…
Intuitive Surgical, Inc.201423
*K152421IS4000 Stapler 30 Instrument and Stapler 30 Reloads
Summary page 4
…General and Plastic Surgery Predicate Device: K140553 – EndoWrist Stapler 45 and Stapler 45 Reloads K152421 – Endowrist Stapler 30 Instrument and Stapler 30 Reloads Intended Use (EndoWrist Stapler 4…
Intuitive Surgical, Inc.20163

Also cleared against K140553: 4 other devices →

What descends from it? (12)

See all 12

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K173721SureForm 60 and SureForm 60 ReloadsIntuitive Surgical20186
K190999SureForm 45 Curved Tip, SureForm 45 Gray ReloadIntuitive Surgical, Inc.20194
K181395Universal Cannula Seal (5-12 mm)Intuitive Surgical, Inc.20184
K222839EndoWrist Stapler 30 System, EndoWrist Stapler 45 System, SureForm 45 System, SureForm… Class IIntuitive Surgical, Inc.20231

Has anything in its family been recalled? (3 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K222839EndoWrist Stapler 30 System, EndoWrist Stapler 45 System, SureForm 45 System, SureForm 60 System, 8 mm…Intuitive Surgical, Inc. · 2023 · Cites it directly · ◆ in the 2023 descendants bar of FIG. 11 Class I recall
  • K2119978 mm SureForm 30 Curved-Tip Stapler, 8 mm SureForm 30 Stapler, SureForm 30 ReloadsIntuitive Surgical, Inc. · 2021 · 2 generations on · ◆ in the 2021 descendants bar of FIG. 11 Class I recall
  • K2416388mm SureForm 30 Curved-Tip Stapler; 8mm SureForm 30 Stapler; 8mm SureForm 30 ReloadsIntuitive Surgical, Inc. · 2024 · 2 generations on · ◆ in the 2024 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 14 years and passes through 2 companies; a new generation was cleared every 12.2 years on median.
  • 2 of the 3 ancestors have a recall of any class.
  • Of its descendants, K173721 (Intuitive Surgical, 2018) has gone furthest, with 6 descendants of its own.
  • 4 other devices also cite its predicate K140553.

How does its category compare?

All NAY devices

NAY System, Surgical, Computer Controlled Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years. 2017, this device’s year, is highlighted.

FDA decisions per year · NAY

16in 2025

2008: 42009: 32010: 12011: 72012: 42013: 42014: 92015: 32016: 82017: 162018: 152019: 82020: 92021: 112022: 62023: 52024: 102025: 162026 (partial year): 7
2007high 16 (2017) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NAY

117in 2025

2008: 189 days median2009: 253 days median2011: 191 days median2012: 106 days median2013: 144 days median2014: 143 days median2015: 99 days median2016: 197 days median2017: 107 days median2018: 152 days median2019: 73 days median2020: 212 days median2021: 61 days median2022: 57 days median2023: 141 days median2024: 126 days median2025: 117 days median2026 (partial year): 89 days median
2007high 253 (2009) · low 57 (2022)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NAY

1in 2025

2007: 112008: 32009: 12011: 22012: 12013: 62014: 252015: 32016: 12017: 12018: 22019: 52021: 32022: 32023: 2, 1 Class I2024: 402025: 12026 (partial year): 4, 1 Class I
2007high 40 (2024) · low 0 (2010)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · NAY

48,456in 2025

2007: 1332008: 2242009: 3802010: 6232011: 5012012: 1,5522013: 6,2172014: 6,1352015: 1,7222016: 1,0772017: 1,0492018: 1,0742019: 1,1542020: 1,5582021: 1,9972022: 5,7272023: 10,8982024: 12,8722025: 48,456
2007high 48,456 (2025) · low 133 (2007)2025

MAUDE reports naming product code NAY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—11133
200841893224
200932531380
20101—0623
201171912501
2012410611,552
2013414466,217
20149143256,135
201539931,722
2016819711,077
20171610711,049
20181515221,074
201987351,154
2020921201,558
2021116131,997
202265735,727
202351412 (1)10,898
2024101264012,872
202516117148,456
20267894 (1)—

What is it indicated for?

The Intuitive Surgical EndoWrist Stapler 45, Stapler 45 Reloads and other Stapler Accessories (including the bladeless obturators) are intended to be used with a compatible da Vinci Surgical System for resection, transection and/or creation of anastomoses in General, Thoracic, Gynecologic and Urologic surgery. The device can be used with staple line or tissue buttressing material (natural or synthetic). The Intuitive Surgical EndoWrist Stapler 30…

Read the full statement (116 words)

The Intuitive Surgical EndoWrist Stapler 45, Stapler 45 Reloads and other Stapler Accessories (including the bladeless obturators) are intended to be used with a compatible da Vinci Surgical System for resection, transection and/or creation of anastomoses in General, Thoracic, Gynecologic and Urologic surgery. The device can be used with staple line or tissue buttressing material (natural or synthetic).

The Intuitive Surgical EndoWrist Stapler 30 Instrument and Stapler 30 Reloads are intended to be used with a compatible da Vinci Surgical System for resection, transection and/or creation of anastomoses in General, Thoracic, Gynecologic, and Urologic surgery. The device is indicated for adult and pediatric use. The device can be used with staple line or tissue buttressing material.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K170508: EndoWrist Stapler 45 Instrument, EndoWrist Stapler 45 Reloads, EndoWrist Stapler 30 Instrument, EndoWrist Stapler 30 Reloads.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K170508

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026