510(k) Report

510(k) · Cleared

Cleared

CoaguChek XS Pro System

K180693510(k) SpecialCleared Apr 19, 201834-day reviewClass II21 CFR 864.7750

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Roche Diagnostics · GJS Test, Time, Prothrombin

Cleared on Apr 19, 2018 as substantially equivalent to K093460 (Roche Diagnostics, 2010) after a 34-day review. Its family tree reaches back 5 generations to 2001. 2 of the 6 devices in its family, counting itself, have a Class I recall.

Decided
Apr 19, 2018
Review
34 days
Class
Class II
Product code
GJS
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K010599 (2001). No later device cites it as a predicate yet. 2 of the 6 devices in this family, counting this one, have a Class I recall.

  1. Root · 5 generations backK010599 Protime Microcoagulation System / Protime 3 CuvetteInternational Technidyne Corp. · 2001 · Recalled
  2. 4 generations backK020831 PT S Test Strips and Controls for the Coaguchek S System, Models…Roche Diagnostics Corp. · 2002
  3. 3 generations backK060978 Coaguchek XS SystemRoche Diagnostics · 2006 · Recalled
  4. 2 generations backK071041 Coaguchek XS Plus SystemRoche Diagnostics · 2007 · Recalled (Class I)
  5. 1 generation backK093460 Coaguchek XS Pro SystemRoche Diagnostics · 2010 · Recalled (Class I)
  6. This deviceK180693 CoaguChek XS Pro SystemRoche Diagnostics · 2018

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K010599Protime Microcoagulation System / Protime 3 CuvetteInternational Technidyne Corp.20013
−4K020831PT S Test Strips and Controls for the Coaguchek S System, Models 2032422 and…Roche Diagnostics Corp.2002—
−3K060978Coaguchek XS SystemRoche Diagnostics20063
−2K071041Coaguchek XS Plus SystemRoche Diagnostics2007Class I
−1K093460Coaguchek XS Pro SystemRoche Diagnostics2010Class I
0 (this device)K180693CoaguChek XS Pro SystemRoche Diagnostics2018—
FIG. 1 — Lineage of K180693, 2001–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GJS device

  1. #1 K243543 microINR Systemscore 13.4 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K093460Coaguchek XS Pro System
Summary page 4
…Sani-Cloth is a General Purpose Disinfectant, a Class I exempt product, according to 21 CFR 880.6890. The CoaguChek XS Pro System has not changed since its clearance on K093460. No technological, material, performance, or design changes to the CoaguChek XS Pro System have been implemented since its cleara…
Roche Diagnostics2010Class I

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K093460Coaguchek XS Pro SystemRoche Diagnostics · 2010 · Direct predicate · ◆ on the line of descent in FIG. 11 Class I recall
  • K071041Coaguchek XS Plus SystemRoche Diagnostics · 2007 · 2 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 17 years and passes through 3 companies; a new generation was cleared every 2.9 years on median.
  • 4 of the 5 ancestors have a recall of any class; 2 have a Class I recall.

How does its category compare?

All GJS devices

GJS Test, Time, Prothrombin: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · GJS

3in 2025

2007: 42008: 12010: 42012: 12013: 12014: 12016: 12017: 12018: 22019: 22020: 12022: 32023: 22024: 12025: 3
2007high 4 (2007) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GJS

60in 2025

2007: 77 days median2010: 168 days median2022: 399 days median2025: 60 days median
2007high 399 (2022) · low 60 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GJS

1in 2022

2007: 52008: 32009: 42010: 22011: 12012: 12013: 12014: 4, 3 Class I2017: 52018: 3, 2 Class I2020: 22021: 12022: 1
2007high 5 (2007) · low 0 (2015)2026

Class I (5 since 2007) Class II/III not classified

Adverse event reports per year · GJS

105in 2025

2007: 4392008: 4202009: 8762010: 2,1772011: 2,9652012: 2,1982013: 2,5842014: 2,3972015: 1,2602016: 8642017: 5322018: 1,9582019: 2,3852020: 1,3902021: 1,3592022: 1,2102023: 8092024: 1772025: 105
2007high 2,965 (2011) · low 105 (2025)2025

MAUDE reports naming product code GJS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074775439
20081—3420
20090—4876
2010416822,177
20110—12,965
20121—12,198
20131—12,584
20141—4 (3)2,397
20150—01,260
20161—0864
20171—5532
20182—3 (2)1,958
20192—02,385
20201—21,390
20210—11,359
2022339911,210
20232—0809
20241—0177
20253600105
20260—0—

What is it indicated for?

The CoaguChek XS Pro System (CoaguChek XS Pro meter and CoaguChek XS PT Test strips) quantitatively determines

prothrombin time ("PT"), using capillary blood or whole blood from a vein (nonanticoagulated venous whole blood). It is

indicated for use by healthcare professionals. The system is ideally suited to monitor coagulation values in people who

are taking oral anticoagulation medication (vitamin K antagonists, VKAs).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K180693: CoaguChek XS Pro System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K180693

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026