510(k) · Cleared
ClearedAmCAD-UO
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Amcad Biomed Corporation · LLZ System, Image Processing, Radiological
Cleared on Dec 28, 2018 as substantially equivalent to K141745 (Edda Technology, 2014) after a 270-day review. Its family tree reaches back 12 generations to 1991.
- Decided
- Dec 28, 2018
- Review
- 270 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 12 generations to K913770 (1991). 54 ancestors in all, the oldest K871859 (1987). No later device cites it as a predicate yet.
- Root · 12 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
- 8 generations between
- 3 generations backK071331 Vitrea Version 4.0Vital Images, Inc. · 2007 · Recalled
- 2 generations backK120484 Visia OncologyMeVis Medical Solutions AG · 2012
- 1 generation backK141745 Iqqa-Bodyimaging SoftwareEdda Technology · 2014
- This deviceK180867 AmCAD-UOAmcad Biomed Corporation · 2018
Show all 12 generations
- Root · 12 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
- 11 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
- 10 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
- 9 generations backK023003 Imagechecker-CT WorkstationR2 Technology, Inc. · 2002
- 8 generations backK032748 VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc. · 2003 · Recalled
- 7 generations backK040305 VITREA2 Version 3.5Vital Images, Inc. · 2004
- 6 generations backK043333 VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · Recalled
- 5 generations backK052632 VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc. · 2005 · Recalled
- 4 generations backK061624 Vitrea, Version 3.9Vital Images, Inc. · 2006 · Recalled
- 3 generations backK071331 Vitrea Version 4.0Vital Images, Inc. · 2007 · Recalled
- 2 generations backK120484 Visia OncologyMeVis Medical Solutions AG · 2012
- 1 generation backK141745 Iqqa-Bodyimaging SoftwareEdda Technology · 2014
- This deviceK180867 AmCAD-UOAmcad Biomed Corporation · 2018
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −12 | K913770 | Advantage V.S. CT/MR Rad Diagnostic Workstation | General Electric Co. | 1991 | — |
| −11 | K960613 | GE Advantage Windows Review Workstation | GE Medical Systems | 1996 | — |
| −10 | K020483 | Advantage Workstation 4.1 | GE Medical Systems | 2002 | 2 |
| −9 | K023003 | Imagechecker-CT Workstation | R2 Technology, Inc. | 2002 | — |
| −8 | K032748 | VITREA2, Version 3.4 Medical Image Processing Software | Vital Images, Inc. | 2003 | 2 |
| −7 | K040305 | VITREA2 Version 3.5 | Vital Images, Inc. | 2004 | — |
| −6 | K043333 | VITREA2, Version 3.7 Medical Image Processing System | Vital Images, Inc. | 2004 | 1 |
| −5 | K052632 | VITREA2 Version 3.8 Medical Image Processing Software | Vital Images, Inc. | 2005 | 2 |
| −4 | K061624 | Vitrea, Version 3.9 | Vital Images, Inc. | 2006 | 1 |
| −3 | K071331 | Vitrea Version 4.0 | Vital Images, Inc. | 2007 | 1 |
| −2 | K120484 | Visia Oncology | MeVis Medical Solutions AG | 2012 | — |
| −1 | K141745 | Iqqa-Bodyimaging Software | Edda Technology | 2014 | — |
| 0 (this device) | K180867 | AmCAD-UO | Amcad Biomed Corporation | 2018 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1987 | 1 | 0 |
| 1993 | 1 | 0 |
| 1994 | 2 | 0 |
| 1995 | 2 | 0 |
| 1996 | 4 | 0 |
| 1997 | 3 | 0 |
| 1998 | 2 | 0 |
| 1999 | 2 | 0 |
| 2000 | 3 | 0 |
| 2001 | 6 | 0 |
| 2002 | 5 | 0 |
| 2003 | 1 | 0 |
| 2004 | 3 | 0 |
| 2005 | 2 | 0 |
| 2006 | 1 | 0 |
| 2007 | 1 | 0 |
| 2008 | 1 | 0 |
| 2011 | 1 | 0 |
| 2013 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K141745 | Iqqa-Bodyimaging SoftwareSummary page 6…is substantially equivalent to the devices listed below: Primary Predicate Device Model: IQQA-Body Imaging Software Manufacturer: EDDA Technology, Inc. 510(k) Number: K141745 5-3 ZrEBRDBRAT AmCad BioMed Corporation FL.3, NO.167, Fu Hsing N. RD., Taipei 105, Taiwan, ROC Tel: +886-2-2713… | 2014 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 27 years and passes through 7 companies; a new generation was cleared every 12 months on median.
- 13 of the 54 ancestors have a recall of any class.
- 3 other devices also cite its predicate K141745.
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
AmCAD-UO is a PC-based, self-contained, non-invasive image analysis software application for reviewing the pharyngeal/upper airway ultrasonic image acquired from an FDA-cleared ultrasound system. The software is designed to support visualization and quantification of the airway sonographic characteristics. The software also provides tools for manual or interactive selection of Region of Interest to allow for analysis of the airway in terms of its size, position and enhancement pattern. This analysis provides information for physician’s evaluation and monitoring of the airway state.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K180867 · printed Nov 4, 2026
Cite this page
510(k) Report. “K180867: AmCAD-UO.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K180867
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026