510(k) Report

510(k) · Cleared

Cleared

Ziostation2

K181892510(k) TraditionalCleared Oct 9, 201888-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ziosoft, Inc. · LLZ System, Image Processing, Radiological

Cleared on Oct 9, 2018 as substantially equivalent to K151212 (Qi Imaging, LLC, 2015) and 7 other predicates after an 88-day review. Its family tree reaches back 14 generations to 1993. 10 of the 278 devices in its family, counting itself, have a Class I recall. 1 later device descends from it.

Decided
Oct 9, 2018
Review
88 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
8

Its longest line of descent runs back 14 generations to K926514 (1993). 276 ancestors in all, the oldest K871859 (1987). 1 later device descends from it, 1 citing it directly. 10 of the 278 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2015: 2 other ancestors2014: 2 other ancestors2013: 5 other ancestors2008: 15 other ancestors2007: 14 other ancestors, 2 with a Class I recall22012: 7 other ancestors2011: 9 other ancestors2009: 9 other ancestors2006: 14 other ancestors2005: 19 other ancestors, 2 with a Class I recall22004: 22 other ancestors, 2 with a Class I recall22003: 15 other ancestors, 2 with a Class I recall22001: 20 other ancestors, 1 with a Class I recall12010: 1 other ancestor2002: 18 other ancestors, 1 with a Class I recall12000: 16 other ancestors1998: 12 other ancestors1997: 8 other ancestors1999: 9 other ancestors1996: 13 other ancestors1995: 7 other ancestors1994: 4 other ancestors1993: 4 other ancestors1987: 1 other ancestor1991: 8 other ancestors1989: 2 other ancestors1988: 3 other ancestors1992: 2 other ancestors1990: 1 other ancestor2020: 1 descendant clearedK926514 · Endoscopic Ultrasound System Type 20 · Olympus Corp. · 1993 · recalledK951994 · Olympus EU-M30 Endoscopic Ultrasound Center · Olympus America, Inc. · 1996K982323 · Olympus UM 2R/3R Ultrasonic Probes and Associated Ancillary Equipment, for Bronchial Use · Olympus America, Inc. · 1998K042438 · Superdimension/Bronchus · Superdimension, Ltd. · 2004 · recalled×2: 2 generations cleared close together, K052260 (2005), K052852 (2005) K062315 · Superdimension/Bronchus Premium 2 · Superdimension, Ltd. · 2006 · recalledK071473 · Modification to Superdimension/Bronchus Premium 2 · Superdimension, Ltd. · 2007×2: 2 generations cleared close together, K080271 (2008), K081379 (2008) K092365 · Inreach System, Model AAS00161-02 · Superdimension, Ltd. · 2009×2: 2 generations cleared close together, K102604 (2010), K110093 (2011) K112051 · Lungpoint Planning and Virtual Bronchoscopic Navigation (VBN) Software · Broncus Technologies, Inc. · 20111990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 7 other ancestors, 1 with a Class I recall12 generations back: 31 other ancestors, 4 with a Class I recall43 generations back: 43 other ancestors4 generations back: 47 other ancestors, 1 with a Class I recall15 generations back: 37 other ancestors, 3 with a Class I recall36 generations back: 34 other ancestors, 1 with a Class I recall17 generations back: 24 other ancestors8 generations back: 14 other ancestors9 generations back: 13 other ancestors10 generations back: 9 other ancestors11 generations back: 2 other ancestors12 generations back: 1 other ancestor 1 generation forward: 1 descendant K112051 · Lungpoint Planning and Virtual Bronchoscopic Navigation (VBN) Software · Broncus Technologies, Inc. · 2011K110093 · Superdimension Marker Delivery Kit · Superdimension, Inc. · 2011K102604 · I-Logic Inreach System · Superdimension, Ltd. · 2010K092365 · Inreach System, Model AAS00161-02 · Superdimension, Ltd. · 2009K081379 · Modification to Inreach System · Superdimension, Ltd. · 2008K080271 · Inreach System · Superdimension, Ltd. · 2008K071473 · Modification to Superdimension/Bronchus Premium 2 · Superdimension, Ltd. · 2007K062315 · Superdimension/Bronchus Premium 2 · Superdimension, Ltd. · 2006 · recalledK052852 · Superdimension/Bronchus Premium · Superdimension, Ltd. · 2005 · recalledK052260 · Superdimension/Bronchus 4.1 · Superdimension, Ltd. · 2005 · recalledK042438 · Superdimension/Bronchus · Superdimension, Ltd. · 2004 · recalledK982323 · Olympus UM 2R/3R Ultrasonic Probes and Associated Ancillary Equipment, for Bronchial Use · Olympus America, Inc. · 1998K951994 · Olympus EU-M30 Endoscopic Ultrasound Center · Olympus America, Inc. · 1996K926514 · Endoscopic Ultrasound System Type 20 · Olympus Corp. · 1993 · recalled−10−50
  1. Root · 14 generations backK926514 Endoscopic Ultrasound System Type 20Olympus Corp. · 1993 · Recalled
  2. 10 generations between
  3. 3 generations backK102604 I-Logic Inreach SystemSuperdimension, Ltd. · 2010
  4. 2 generations backK110093 Superdimension Marker Delivery KitSuperdimension, Inc. · 2011
  5. 1 generation backK112051 Lungpoint Planning and Virtual Bronchoscopic Navigation (VBN) SoftwareBroncus Technologies, Inc. · 2011
  6. This deviceK181892 Ziostation2Ziosoft, Inc. · 2018
  7. Descendant · cites it directly · 0 of its ownK200315 Ziostation2Ziosoft, Inc. · 2020
Show all 14 generations
  1. Root · 14 generations backK926514 Endoscopic Ultrasound System Type 20Olympus Corp. · 1993 · Recalled
  2. 13 generations backK951994 Olympus EU-M30 Endoscopic Ultrasound CenterOlympus America, Inc. · 1996
  3. 12 generations backK982323 Olympus UM 2R/3R Ultrasonic Probes and Associated Ancillary…Olympus America, Inc. · 1998
  4. 11 generations backK042438 Superdimension/BronchusSuperdimension, Ltd. · 2004 · Recalled
  5. 10 generations backK052260 Superdimension/Bronchus 4.1Superdimension, Ltd. · 2005 · Recalled
  6. 9 generations backK052852 Superdimension/Bronchus PremiumSuperdimension, Ltd. · 2005 · Recalled
  7. 8 generations backK062315 Superdimension/Bronchus Premium 2Superdimension, Ltd. · 2006 · Recalled
  8. 7 generations backK071473 Modification to Superdimension/Bronchus Premium 2Superdimension, Ltd. · 2007
  9. 6 generations backK080271 Inreach SystemSuperdimension, Ltd. · 2008
  10. 5 generations backK081379 Modification to Inreach SystemSuperdimension, Ltd. · 2008
  11. 4 generations backK092365 Inreach System, Model AAS00161-02Superdimension, Ltd. · 2009
  12. 3 generations backK102604 I-Logic Inreach SystemSuperdimension, Ltd. · 2010
  13. 2 generations backK110093 Superdimension Marker Delivery KitSuperdimension, Inc. · 2011
  14. 1 generation backK112051 Lungpoint Planning and Virtual Bronchoscopic Navigation (VBN) SoftwareBroncus Technologies, Inc. · 2011
  15. This deviceK181892 Ziostation2Ziosoft, Inc. · 2018

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K200315Ziostation2Ziosoft, Inc. · 2020 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−14K926514Endoscopic Ultrasound System Type 20Olympus Corp.19931
−13K951994Olympus EU-M30 Endoscopic Ultrasound CenterOlympus America, Inc.1996—
−12K982323Olympus UM 2R/3R Ultrasonic Probes and Associated Ancillary Equipment, for…Olympus America, Inc.1998—
−11K042438Superdimension/BronchusSuperdimension, Ltd.20041
−10K052260Superdimension/Bronchus 4.1Superdimension, Ltd.20052
−9K052852Superdimension/Bronchus PremiumSuperdimension, Ltd.20051
−8K062315Superdimension/Bronchus Premium 2Superdimension, Ltd.20061
−7K071473Modification to Superdimension/Bronchus Premium 2Superdimension, Ltd.2007—
−6K080271Inreach SystemSuperdimension, Ltd.2008—
−5K081379Modification to Inreach SystemSuperdimension, Ltd.2008—
−4K092365Inreach System, Model AAS00161-02Superdimension, Ltd.2009—
−3K102604I-Logic Inreach SystemSuperdimension, Ltd.2010—
−2K110093Superdimension Marker Delivery KitSuperdimension, Inc.2011—
−1K112051Lungpoint Planning and Virtual Bronchoscopic Navigation (VBN) SoftwareBroncus Technologies, Inc.2011—
0 (this device)K181892Ziostation2Ziosoft, Inc.2018—
+1K200315Ziostation2Ziosoft, Inc.2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198830
198920
199010
199180
199220
199340
199440
199570
1996130
199780
1998120
199990
2000160
2001201
2002181
2003152
2004222
2005192
2006140
2007142
2008150
200990
201010
201190
201270
201350
201420
201520

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202010
FIG. 1 — Lineage of K181892, 1993–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

10 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (8)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K151212Ziostation2
Summary page 5
…Device Name Number Ziostation2 K151212 CT PULMONARY ANALYSIS K130552 SYNAPSE 3D LUNG AND A…
Qi Imaging, LLC2015—
*K130552CT Pulmonary Analysis
Summary page 5
…Number Ziostation2 K151212 CT PULMONARY ANALYSIS K130552 SYNAPSE 3D LUNG AND ABDOMEN ANALYSIS K130542 LUNGPOINT PLANNING AND VIR…
Qi Imaging, LLC2014—
*K130542Synapse 3D Lung and Abdomen Analysis
Summary page 5
…K151212 CT PULMONARY ANALYSIS K130552 SYNAPSE 3D LUNG AND ABDOMEN ANALYSIS K130542 LUNGPOINT PLANNING AND VIRTUAL BRONCHOSCOPIC…
Fujifilm Medical System U.S.A., Inc.2013—
*K112051Lungpoint Planning and Virtual Bronchoscopic Navigation (VBN) Software
Summary page 5
…NALYSIS K130542 LUNGPOINT PLANNING AND VIRTUAL BRONCHOSCOPIC K112051 NAVIGATION (VBN) SOFTWARE IQQA-BODYIMAGING SOFTWARE…
Broncus Technologies, Inc.2011—
*K141745Iqqa-Bodyimaging Software
Summary page 5
…K112051 NAVIGATION (VBN) SOFTWARE IQQA-BODYIMAGING SOFTWARE K141745 SYNGO MR B17 K082427 MR-CT V…
Edda Technology2014—
*K082427Syngo MR B17
Summary page 5
…N) SOFTWARE IQQA-BODYIMAGING SOFTWARE K141745 SYNGO MR B17 K082427 MR-CT VVA K140587 ACHIEVA, INTERA AND PANOR…
Siemens Medical Solutions USA, Inc.2008—
*K140587MR-CT Vva
Summary page 5
…K141745 SYNGO MR B17 K082427 MR-CT VVA K140587 ACHIEVA, INTERA AND PANORAMA 1.0T, RELEASE 2.5 K063559 The already-cleared Ziostation2 (K1…
Medis Medical Imaging Systems BV2015—
*K063559Achieva, Intera and Panorama 1.0T, Release 2.5
Summary page 5
…K082427 MR-CT VVA K140587 ACHIEVA, INTERA AND PANORAMA 1.0T, RELEASE 2.5 K063559 The already-cleared Ziostation2 (K151212) is the primary predicate device. Device Description Ziostation2 is a basic…
Philips Medical Systems2007Class I

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K200315Ziostation2Ziosoft, Inc.20200

Has anything in its family been recalled? (10 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K063559Achieva, Intera and Panorama 1.0T, Release 2.5Philips Medical Systems · 2007 · Direct predicate · ◆ in the 2007 ancestors bar of FIG. 11 Class I recall
  • K072237Magnetom VerioSiemens Medical Solutions USA, Inc. · 2007 · 2 generations back · ◆ in the 2007 ancestors bar of FIG. 11 Class I recall
  • K052078Achieva, Intera and Panorama 1.0 Release 2-SeriesPhilips Medical Systems Nederland B.V. · 2005 · 2 generations back · ◆ in the 2005 ancestors bar of FIG. 11 Class I recall
  • K043147Achieva FamilyPhilips Medical Systems North America Co. · 2005 · 2 generations back · ◆ in the 2005 ancestors bar of FIG. 13 Class I recalls
  • K041602Panorama 1.0TPhilips Medical Systems North America, Inc. · 2004 · 2 generations back · ◆ in the 2004 ancestors bar of FIG. 11 Class I recall
  • K041476GE Signa Excite 1.5T MR System, GE Signa Excite 3.0T MR SystemGe Medical Systems, LLC · 2004 · 4 generations back · ◆ in the 2004 ancestors bar of FIG. 11 Class I recall
  • K030874GE 3.0T Signa Infinity Twinspeed with Excite MR SystemGeneral Electric Co. · 2003 · 5 generations back · ◆ in the 2003 ancestors bar of FIG. 11 Class I recall
  • K023984Modification to Olympus Bronchoscopes BF-40 Series, BF-240 Series, and BF-160 SeriesThe Olympus Optical Co. · 2003 · 5 generations back · ◆ in the 2003 ancestors bar of FIG. 114 Class I recalls
  • K013636Signa Infinity MR System with Excite TechnologyGE Medical Systems · 2002 · 5 generations back · ◆ in the 2002 ancestors bar of FIG. 11 Class I recall
  • K0122001.5T Infinity Twinspeed MR SystemGE Medical Systems · 2001 · 6 generations back · ◆ in the 2001 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 25 years and passes through 6 companies; a new generation was cleared every 10 months on median.
  • 85 of the 276 ancestors have a recall of any class; 10 have a Class I recall.
  • Of its descendants, K200315 (Ziosoft, Inc., 2020) has gone furthest, with 0 descendants of its own.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

•This application is image processing application software available for installation onto customer-owned hardware. This application software can be networked to provide for sharing of resources. •This application software receives medical image data (CT, MRI, Ultrasound, Digital X-ray, X-ray Angiography, PET, SPECT, Nuclear Medicine, Secondary Capture, Mammography, X-ray Radiofluoroscopic image, and RT Image) from modalities or image archives such as…

Read the full statement (143 words)

•This application is image processing application software available for installation onto customer-owned hardware. This application software can be networked to provide for sharing of resources.

•This application software receives medical image data (CT, MRI, Ultrasound, Digital X-ray, X-ray Angiography, PET, SPECT, Nuclear Medicine, Secondary Capture, Mammography, X-ray Radiofluoroscopic image, and RT Image) from modalities or image archives such as PACS through network or media, and provides for the viewing, quantification, manipulation, communication, printing and management of medical images.

•This application software is intended only for use by trained medical professionals to supplement generally accepted methods of interpreting radiological images.

•Lossy compressed mammographic images and digitized film screen images must not be reviewed for primary image interpretations. Mammographic images may only be interpreted using a monitor whose characteristics are approved by the regulatory agency governing the market within which this application is being offered.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K181892: Ziostation2.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K181892

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026