510(k) Report

510(k) · Cleared

Cleared

SelectFlex 072 Neurovascular Access System

K181000510(k) TraditionalCleared Sep 13, 2018150-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Q'Apel · DQY Catheter, Percutaneous

Cleared on Sep 13, 2018 as substantially equivalent to K142321 (Penumbra, Inc., 2015) after a 150-day review. Its family tree reaches back 6 generations to 2001. 3 later devices descend from it.

Decided
Sep 13, 2018
Review
150 days
Class
Class II
Product code
DQY
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K010954 (2001). 8 ancestors in all, the oldest K010853 (2001). 3 later devices descend from it, 1 citing it directly.

  1. Root · 6 generations backK010954 Concentric Balloon Guide Catheter, Model 90031Concentric Medical, Inc. · 2001 · Recalled
  2. 5 generations backK021899 Concentric Balloon Guide Catheter, Model 90072Concentric Medical, Inc. · 2002 · Recalled
  3. 4 generations backK053491 Penumbra Balloon Guide Catheter, Model 7.5FPenumbra, Inc. · 2006
  4. 3 generations backK070970 Neuron Support Catheter System, Model 5F/6FPenumbra, Inc. · 2007 · Recalled
  5. 2 generations backK082290 Neuron Delivery Catheter 070Penumbra, Inc. · 2008 · Recalled
  6. 1 generation backK142321 Benchmark Intracranial Access SystemPenumbra, Inc. · 2015
  7. This deviceK181000 SelectFlex 072 Neurovascular Access SystemQ'Apel · 2018
  8. Descendant · cites it directly · 2 of its ownK191664 SelectFlex 072 Neurovascular Access SystemQ'Apel Medical · 2019
  9. Descendant · 2 generations on · 1 of its ownK211893 SelectFlex Neurovascular Access System FamilyQ'Apel Medical, Inc. · 2021
  10. Descendant · 3 generations on · 0 of its ownK240746 Neurovascular Access System FamilyQ'Apel Medical, Inc. · 2024

Most influential descendants

Showing 3 of 3 · See all
  • K191664SelectFlex 072 Neurovascular Access SystemQ'Apel Medical · 2019 · cites it directly2descendants
  • K211893SelectFlex Neurovascular Access System FamilyQ'Apel Medical, Inc. · 2021 · 2 generations on1descendant
  • K240746Neurovascular Access System FamilyQ'Apel Medical, Inc. · 2024 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K010954Concentric Balloon Guide Catheter, Model 90031Concentric Medical, Inc.20011
−5K021899Concentric Balloon Guide Catheter, Model 90072Concentric Medical, Inc.20021
−4K053491Penumbra Balloon Guide Catheter, Model 7.5FPenumbra, Inc.2006—
−3K070970Neuron Support Catheter System, Model 5F/6FPenumbra, Inc.20071
−2K082290Neuron Delivery Catheter 070Penumbra, Inc.20081
−1K142321Benchmark Intracranial Access SystemPenumbra, Inc.2015—
0 (this device)K181000SelectFlex 072 Neurovascular Access SystemQ'Apel2018—
+1K191664SelectFlex 072 Neurovascular Access SystemQ'Apel Medical2019—
+2K211893SelectFlex Neurovascular Access System FamilyQ'Apel Medical, Inc.2021—
+3K240746Neurovascular Access System FamilyQ'Apel Medical, Inc.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110
200810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
202110
202410
FIG. 1 — Lineage of K181000, 2001–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQY device

  1. #1 K234115 APRO 55 Catheterscore 17.5 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K142321Benchmark Intracranial Access System
Summary page 4
…Class II Product Code(s): DQY Regulation Number(s): 870.1250 Predicate Devices: Penumbra Benchmark Intracranial Access System, (K142321) Reference Devices: Depuy Synthes Envoy Guiding Catheter STR (K965247, K982770) Dep…
Penumbra, Inc.2015—
†K965247Envoy Guiding CatheterCordis Neurovascular, Inc.1997—
†K9827706F Envoy Guiding CatheterCordis Corp.1998—
†K140307Envoy Guiding CatheterCodman & Shurtleff, Inc.2014—
†K142819Shuttle SL Flexor Tuohy-Borst Side-Arm Introducer SetCook Incorporated2015—

Also cleared against K142321: 3 other devices →

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K191664SelectFlex 072 Neurovascular Access SystemQ'Apel Medical20192

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 3 companies; a new generation was cleared every 3.6 years on median.
  • 6 of the 8 ancestors have a recall of any class.
  • Of its descendants, K191664 (Q'Apel Medical, 2019) has gone furthest, with 2 descendants of its own.
  • 3 other devices also cite its predicate K142321.

How does its category compare?

All DQY devices

DQY Catheter, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · DQY

21in 2025

2007: 162008: 312009: 372010: 222011: 362012: 302013: 322014: 192015: 272016: 222017: 262018: 252019: 302020: 202021: 182022: 182023: 182024: 162025: 212026 (partial year): 11
2007high 37 (2009) · low 16 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQY

115in 2025

2007: 85 days median2008: 66 days median2009: 73 days median2010: 74 days median2011: 71 days median2012: 87 days median2013: 92 days median2014: 127 days median2015: 118 days median2016: 117 days median2017: 113 days median2018: 106 days median2019: 111 days median2020: 120 days median2021: 81 days median2022: 74 days median2023: 114 days median2024: 87 days median2025: 115 days median2026 (partial year): 30 days median
2007high 127 (2014) · low 66 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQY

1in 2025

2007: 62008: 122009: 172010: 322011: 62012: 22013: 36, 1 Class I2014: 32015: 32016: 22, 7 Class I2017: 82018: 22019: 12020: 22021: 22023: 172024: 12025: 1, 1 Class I2026 (partial year): 2, 1 Class I
2007high 36 (2013) · low 0 (2022)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · DQY

3,056in 2025

2007: 3132008: 4962009: 8192010: 1,2932011: 1,2112012: 1,1912013: 1,3522014: 1,4972015: 2,3372016: 2,2522017: 2,4892018: 2,8552019: 2,9022020: 2,8892021: 3,0062022: 2,6432023: 3,0492024: 3,1902025: 3,056
2007high 3,190 (2024) · low 313 (2007)2025

MAUDE reports naming product code DQY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200716856313
2008316612496
2009377317819
20102274321,293
2011367161,211
2012308721,191
2013329236 (1)1,352
20141912731,497
20152711832,337
20162211722 (7)2,252
20172611382,489
20182510622,855
20193011112,902
20202012022,889
2021188123,006
2022187402,643
202318114173,049
2024168713,190
2025211151 (1)3,056
202611302 (1)—

What is it indicated for?

The SelectFlex 072 Neurovascular Access System is indicated for the introduction of interventional devices into the peripheral and neurovasculature.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K181000: SelectFlex 072 Neurovascular Access System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K181000

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026