510(k) · Cleared
ClearedMedline ReNewal Reprocessed OxiMax Pulse Oximetry Sensors
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Surgical Instrument Service and Savings Inc (Dba Medline · DQA Oximeter
Cleared on Mar 22, 2019 as substantially equivalent to K052186 (Nellcor Puritan Bennett, Inc., 2005) after a 263-day review. Its family tree reaches back 7 generations to 1997. 1 later device descends from it.
- Decided
- Mar 22, 2019
- Review
- 263 days
- Class
- Class II
- Product code
- DQA
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 7 generations to K962603 (1997). 11 ancestors in all, the oldest K904039 (1990). 1 later device descends from it, 1 citing it directly.
- Root · 7 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
- 6 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
- 5 generations backK982255 Model 2000 Pulse OximeterIvy Biomedical Systems, Inc. · 1998
- 4 generations backK991823 N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc. · 1999
- 3 generations backK012891 Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax…Nellcor Puritan Bennett, Inc. · 2002 · Recalled
- 2 generations backK021089 Oximax Max-Fast Adhesive Forehead SensorNellcor Puritan Bennett, Inc. · 2002
- 1 generation backK052186 Nellcor Oximax Pulse Oximetry Sensons (Max-a, Max-AL, Max-N, Max-I…Nellcor Puritan Bennett, Inc. · 2005
- This deviceK181738 Medline ReNewal Reprocessed OxiMax Pulse Oximetry SensorsSurgical Instrument Service and Savings Inc (Dba Medline · 2019
- Descendant · cites it directly · 0 of its ownK201699 Medline ReNewal Reprocessed Nellcor OxiMax SpO2 SensorSurgical Instrument and Savings Inc (Dba Medline Renewal) · 2020
Most influential descendants
Showing 1 of 1 · See all- K201699Medline ReNewal Reprocessed Nellcor OxiMax SpO2 SensorSurgical Instrument and Savings Inc (Dba Medline Renewal) · 2020 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −7 | K962603 | Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables | Masimo Corp. | 1997 | — |
| −6 | K973887 | Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables | Masimo Corp. | 1998 | — |
| −5 | K982255 | Model 2000 Pulse Oximeter | Ivy Biomedical Systems, Inc. | 1998 | — |
| −4 | K991823 | N-395 Pulse Oximeter, Model N-395 | Nellcor Puritan Bennett, Inc. | 1999 | — |
| −3 | K012891 | Oximax Pulse Oximetry System with N-595 Pulse Oximeter and Oximax Sensors and… | Nellcor Puritan Bennett, Inc. | 2002 | 1 |
| −2 | K021089 | Oximax Max-Fast Adhesive Forehead Sensor | Nellcor Puritan Bennett, Inc. | 2002 | — |
| −1 | K052186 | Nellcor Oximax Pulse Oximetry Sensons (Max-a, Max-AL, Max-N, Max-I, Max-P | Nellcor Puritan Bennett, Inc. | 2005 | — |
| 0 (this device) | K181738 | Medline ReNewal Reprocessed OxiMax Pulse Oximetry Sensors | Surgical Instrument Service and Savings Inc (Dba Medline | 2019 | — |
| +1 | K201699 | Medline ReNewal Reprocessed Nellcor OxiMax SpO2 Sensor | Surgical Instrument and Savings Inc (Dba Medline Renewal) | 2020 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1990 | 1 | 0 |
| 1995 | 1 | 0 |
| 1996 | 1 | 0 |
| 1999 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2020 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DQA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DQA device
- #1 K221282 Empatica Health Monitoring Platformscore 20.1 · 38 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K052186 | Nellcor Oximax Pulse Oximetry Sensons (Max-a, Max-AL, Max-N, Max-I, Max-PSummary page 4…atory Class: Class II Product Code: NLF Panel: Cardiovascular/anesthesiology 510(k) number: K052186 Nellcor OxiMax Pulse Oximeter Sensors, models Proprietary/Trade… | 2005 |
| † | K041867 | Hygia Health Services Reprocessed Oximax Sensors Model # HHS-Max-a, HHS-Max-AL, HHS-Max-N | 2004 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K201699 | Medline ReNewal Reprocessed Nellcor OxiMax SpO2 Sensor | 2020 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 22 years and passes through 4 companies; a new generation was cleared every 11 months on median.
- 3 of the 11 ancestors have a recall of any class.
- Of its descendants, K201699 (Surgical Instrument and Savings Inc (Dba Medline Renewal), 2020) has gone furthest, with 0 descendants of its own.
- 1 other device also cites its predicate K052186.
How does its category compare?
All DQA devicesDQA Oximeter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.
FDA decisions per year · DQA
15in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DQA
182in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DQA
3in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DQA
399in 2025
MAUDE reports naming product code DQA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 20 | 122 | 6 | 325 |
| 2008 | 22 | 97 | 5 | 312 |
| 2009 | 35 | 117 | 29 | 281 |
| 2010 | 29 | 127 | 4 | 185 |
| 2011 | 15 | 195 | 1 | 164 |
| 2012 | 14 | 120 | 0 | 322 |
| 2013 | 15 | 182 | 0 | 468 |
| 2014 | 11 | 175 | 2 | 1,124 |
| 2015 | 13 | 158 | 1 | 2,082 |
| 2016 | 14 | 246 | 0 | 1,775 |
| 2017 | 9 | 200 | 0 | 1,190 |
| 2018 | 18 | 260 | 32 | 694 |
| 2019 | 19 | 158 | 0 | 548 |
| 2020 | 15 | 126 | 0 | 426 |
| 2021 | 10 | 174 | 0 | 553 |
| 2022 | 20 | 265 | 0 | 478 |
| 2023 | 13 | 317 | 0 | 392 |
| 2024 | 14 | 285 | 3 | 545 |
| 2025 | 15 | 182 | 0 | 399 |
| 2026 | 8 | 187 | 0 | — |
What is it indicated for?
The Medline ReNewal Reprocessed Nellcor OxiMax SpO2 Sensors models MAXA, MAXAL, MAXP, and MAXI are indicated for single patient use when continuous noninvasive arterial oxygen saturation and pulse rate monitoring are required for patients in the sizes indicated in the respective sensor directions for use. These devices are for prescription use only.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K181738 · printed Nov 6, 2026
Cite this page
510(k) Report. “K181738: Medline ReNewal Reprocessed OxiMax Pulse Oximetry Sensors.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K181738
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026