510(k) Report

510(k) · Cleared

Cleared

Intuitive Surgical Vessel Sealer Extend

K183107510(k) TraditionalCleared Dec 11, 201833-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Intuitive Surgical, Inc. · NAY System, Surgical, Computer Controlled Instrument

Cleared on Dec 11, 2018 as substantially equivalent to K173337 (Intuitive Surgical, Inc., 2018) after a 33-day review. Its family tree reaches back 17 generations to 1994. 6 later devices descend from it.

Decided
Dec 11, 2018
Review
33 days
Class
Class II
Product code
NAY
Recalls
None
Predicates
1

Its longest line of descent runs back 17 generations to K930667 (1994). 103 ancestors in all, the oldest K811390 (1981). 6 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2015: 1 other ancestor2014: 1 other ancestor2013: 1 other ancestor2011: 2 other ancestors2010: 2 other ancestors2009: 3 other ancestors2007: 3 other ancestors2004: 4 other ancestors2001: 8 other ancestors2008: 2 other ancestors2006: 3 other ancestors2005: 2 other ancestors2003: 2 other ancestors2002: 4 other ancestors1999: 2 other ancestors1995: 10 other ancestors1992: 4 other ancestors1991: 4 other ancestors1990: 1 other ancestor2000: 1 other ancestor1998: 4 other ancestors1997: 6 other ancestors1994: 8 other ancestors1993: 3 other ancestors1996: 2 other ancestors1988: 2 other ancestors1981: 1 other ancestor2019: 1 descendant cleared2025: 1 descendant cleared2022: 1 descendant cleared2023: 1 descendant cleared2024: 1 descendant cleared2026: 1 descendant clearedK930667 · Reusable Laparoscopic Instruments · Snowden-Pencer · 1994 · recalledK960400 · Diamond-Touch and Micro Diamond-Touch Instruments/Diamond-Line Instruments/Diamond-Port (Access Parts) · Snowden-Pencer · 1996K990144 · Intuitive Surgical Endoscopic Instruments, Intuitive Surgical Endoscopic Instrument Control System · Intuitive Surgical, Inc. · 2000 · recalledK021036 · Intuitive Surgical DA Vinci Surgical System, Model IS1000 · Intuitive Surgical, Inc. · 2002 · recalled×5: 5 generations cleared close together, K040237 (2004), K043153 (2004), K050005 (2005), K050404 (2005), K050802 (2005) K063220 · DA Vinci S Surgical System-V1.1, Model IS2000 · Intuitive Surgical, Inc. · 2006 · recalledK081137 · Intuitive Surgical DA Vinci SI Surgical System: Model IS3000 · Intuitive Surgical, Inc. · 2009 · recalled×2: 2 generations cleared close together, K112208 (2011), K120215 (2012) K122532 · DA Vinci Single-Site Instruments and Accessories · Intuitive Surgical, Inc. · 2013 · recalledK152448 · da Vinci Single-Site Instrument and Accessories · Intuitive Surgical, Inc. · 2016 · recalledK170865 · EndoWrist Vessel Sealer, 8 mm Harmonic ACE Curved Shears, da Vinci Single-Site Instruments and Accessories · Intuitive Surgical, Inc. · 2017K173337 · Intuitive Surgical EndoWrist Vessel Sealer Extend · Intuitive Surgical, Inc. · 2018 · recalled19801990200020102020
Other ancestors, by generationDescendants, by generation 3 generations back: 2 other ancestors4 generations back: 3 other ancestors5 generations back: 5 other ancestors6 generations back: 21 other ancestors7 generations back: 17 other ancestors8 generations back: 27 other ancestors9 generations back: 8 other ancestors10 generations back: 3 other ancestors 1 generation forward: 2 descendants2 generations forward: 1 descendant3 generations forward: 1 descendant4 generations forward: 1 descendant5 generations forward: 1 descendant K173337 · Intuitive Surgical EndoWrist Vessel Sealer Extend · Intuitive Surgical, Inc. · 2018 · recalledK170865 · EndoWrist Vessel Sealer, 8 mm Harmonic ACE Curved Shears, da Vinci Single-Site Instruments and Accessories · Intuitive Surgical, Inc. · 2017K152448 · da Vinci Single-Site Instrument and Accessories · Intuitive Surgical, Inc. · 2016 · recalledK122532 · DA Vinci Single-Site Instruments and Accessories · Intuitive Surgical, Inc. · 2013 · recalledK120215 · Single-Site Medium-Large Clip Applier, Single-Site Cadiere Grasper, Single-Site Fundus Grasper, Single-Site Crocodile · Intuitive Surgical, Inc. · 2012 · recalledK112208 · Intutive Surgical DA Vinci Single Site Instruments and Accessories · Intuitive Surgical, Inc. · 2011 · recalledK081137 · Intuitive Surgical DA Vinci SI Surgical System: Model IS3000 · Intuitive Surgical, Inc. · 2009 · recalledK063220 · DA Vinci S Surgical System-V1.1, Model IS2000 · Intuitive Surgical, Inc. · 2006 · recalledK050802 · Modification to Intuitive Surgical DA Vinci Surgical System and Endoscopic Instruments · Intuitive Surgical, Inc. · 2005K050404 · Intuitive Surgical DA Vinci Surgical System and Endoscopic Instruments · Intuitive Surgical, Inc. · 2005K050005 · Intuitive Surgical Monopolar Curved Scissors, Model 400179; Tip Cover Accessory, Model 400180 · Intuitive Surgical, Inc. · 2005 · recalledK043153 · Intuitive Surgical DA Vinci Surgical System and Endoscopic Instruments, Models IS1200 & IS1000 · Intuitive Surgical, Inc. · 2004K040237 · Intuitive Surgical DA Vinci Endoscopic Instrument Control System and Endoscopic Instruments · Intuitive Surgical, Inc. · 2004K021036 · Intuitive Surgical DA Vinci Surgical System, Model IS1000 · Intuitive Surgical, Inc. · 2002 · recalledK990144 · Intuitive Surgical Endoscopic Instruments, Intuitive Surgical Endoscopic Instrument Control System · Intuitive Surgical, Inc. · 2000 · recalledK960400 · Diamond-Touch and Micro Diamond-Touch Instruments/Diamond-Line Instruments/Diamond-Port (Access Parts) · Snowden-Pencer · 1996K930667 · Reusable Laparoscopic Instruments · Snowden-Pencer · 1994 · recalled−15−10−50+5
  1. Root · 17 generations backK930667 Reusable Laparoscopic InstrumentsSnowden-Pencer · 1994 · Recalled
  2. 13 generations between
  3. 3 generations backK152448 da Vinci Single-Site Instrument and AccessoriesIntuitive Surgical, Inc. · 2016 · Recalled
  4. 2 generations backK170865 EndoWrist Vessel Sealer, 8 mm Harmonic ACE Curved Shears, da Vinci…Intuitive Surgical, Inc. · 2017
  5. 1 generation backK173337 Intuitive Surgical EndoWrist Vessel Sealer ExtendIntuitive Surgical, Inc. · 2018 · Recalled
  6. This deviceK183107 Intuitive Surgical Vessel Sealer ExtendIntuitive Surgical, Inc. · 2018
  7. Descendant · cites it directly · 4 of its ownK191280 E-100 Electrosurgical Generator, SynchroSealIntuitive Surgical, Inc. · 2019 · Recalled
  8. Descendant · 2 generations on · 3 of its ownK223039 da Vinci E-200 Electrosurgical GeneratorIntuitive Surgical · 2022
  9. Descendant · 3 generations on · 2 of its ownK231212 da Vinci E-200 Electrosurgical GeneratorIntuitive Surgical · 2023
  10. Descendant · 4 generations on · 1 of its ownK241635 da Vinci E-200 Electrosurgical GeneratorIntuitive Surgical · 2024
  11. Descendant · 5 generations on · 0 of its ownK253556 da Vinci SP Surgical System (SP1098); da Vinci E-200 GeneratorIntuitive Surgical, Inc. · 2026
Show all 17 generations
  1. Root · 17 generations backK930667 Reusable Laparoscopic InstrumentsSnowden-Pencer · 1994 · Recalled
  2. 16 generations backK960400 Diamond-Touch and Micro Diamond-Touch Instruments/Diamond-Line…Snowden-Pencer · 1996
  3. 15 generations backK990144 Intuitive Surgical Endoscopic Instruments, Intuitive Surgical…Intuitive Surgical, Inc. · 2000 · Recalled
  4. 14 generations backK021036 Intuitive Surgical DA Vinci Surgical System, Model IS1000Intuitive Surgical, Inc. · 2002 · Recalled
  5. 13 generations backK040237 Intuitive Surgical DA Vinci Endoscopic Instrument Control System and…Intuitive Surgical, Inc. · 2004
  6. 12 generations backK043153 Intuitive Surgical DA Vinci Surgical System and Endoscopic…Intuitive Surgical, Inc. · 2004
  7. 11 generations backK050005 Intuitive Surgical Monopolar Curved Scissors, Model 400179; Tip…Intuitive Surgical, Inc. · 2005 · Recalled
  8. 10 generations backK050404 Intuitive Surgical DA Vinci Surgical System and Endoscopic InstrumentsIntuitive Surgical, Inc. · 2005
  9. 9 generations backK050802 Modification to Intuitive Surgical DA Vinci Surgical System and…Intuitive Surgical, Inc. · 2005
  10. 8 generations backK063220 DA Vinci S Surgical System-V1.1, Model IS2000Intuitive Surgical, Inc. · 2006 · Recalled
  11. 7 generations backK081137 Intuitive Surgical DA Vinci SI Surgical System: Model IS3000Intuitive Surgical, Inc. · 2009 · Recalled
  12. 6 generations backK112208 Intutive Surgical DA Vinci Single Site Instruments and AccessoriesIntuitive Surgical, Inc. · 2011 · Recalled
  13. 5 generations backK120215 Single-Site Medium-Large Clip Applier, Single-Site Cadiere Grasper…Intuitive Surgical, Inc. · 2012 · Recalled
  14. 4 generations backK122532 DA Vinci Single-Site Instruments and AccessoriesIntuitive Surgical, Inc. · 2013 · Recalled
  15. 3 generations backK152448 da Vinci Single-Site Instrument and AccessoriesIntuitive Surgical, Inc. · 2016 · Recalled
  16. 2 generations backK170865 EndoWrist Vessel Sealer, 8 mm Harmonic ACE Curved Shears, da Vinci…Intuitive Surgical, Inc. · 2017
  17. 1 generation backK173337 Intuitive Surgical EndoWrist Vessel Sealer ExtendIntuitive Surgical, Inc. · 2018 · Recalled
  18. This deviceK183107 Intuitive Surgical Vessel Sealer ExtendIntuitive Surgical, Inc. · 2018

Showing 5 of 6 descendants. See all descendants

Descendants cleared per year

2019: 12022: 12023: 12024: 12025: 12026: 1
2019high 1 (2019) · low 0 (2020)2026

Most influential descendants

Showing 5 of 6 · See all
  • K191280E-100 Electrosurgical Generator, SynchroSealIntuitive Surgical, Inc. · 2019 · cites it directly4descendants
  • K223039da Vinci E-200 Electrosurgical GeneratorIntuitive Surgical · 2022 · 2 generations on3descendants
  • K231212da Vinci E-200 Electrosurgical GeneratorIntuitive Surgical · 2023 · 3 generations on2descendants
  • K241635da Vinci E-200 Electrosurgical GeneratorIntuitive Surgical · 2024 · 4 generations on1descendant
  • K253556da Vinci SP Surgical System (SP1098); da Vinci E-200 GeneratorIntuitive Surgical, Inc. · 2026 · 5 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−17K930667Reusable Laparoscopic InstrumentsSnowden-Pencer199415
−16K960400Diamond-Touch and Micro Diamond-Touch Instruments/Diamond-Line…Snowden-Pencer1996—
−15K990144Intuitive Surgical Endoscopic Instruments, Intuitive Surgical Endoscopic…Intuitive Surgical, Inc.20003
−14K021036Intuitive Surgical DA Vinci Surgical System, Model IS1000Intuitive Surgical, Inc.200218
−13K040237Intuitive Surgical DA Vinci Endoscopic Instrument Control System and…Intuitive Surgical, Inc.2004—
−12K043153Intuitive Surgical DA Vinci Surgical System and Endoscopic Instruments, Models…Intuitive Surgical, Inc.2004—
−11K050005Intuitive Surgical Monopolar Curved Scissors, Model 400179; Tip Cover…Intuitive Surgical, Inc.20052
−10K050404Intuitive Surgical DA Vinci Surgical System and Endoscopic InstrumentsIntuitive Surgical, Inc.2005—
−9K050802Modification to Intuitive Surgical DA Vinci Surgical System and Endoscopic…Intuitive Surgical, Inc.2005—
−8K063220DA Vinci S Surgical System-V1.1, Model IS2000Intuitive Surgical, Inc.20064
−7K081137Intuitive Surgical DA Vinci SI Surgical System: Model IS3000Intuitive Surgical, Inc.200925
−6K112208Intutive Surgical DA Vinci Single Site Instruments and AccessoriesIntuitive Surgical, Inc.201112
−5K120215Single-Site Medium-Large Clip Applier, Single-Site Cadiere Grasper…Intuitive Surgical, Inc.20123
−4K122532DA Vinci Single-Site Instruments and AccessoriesIntuitive Surgical, Inc.20136
−3K152448da Vinci Single-Site Instrument and AccessoriesIntuitive Surgical, Inc.20161
−2K170865EndoWrist Vessel Sealer, 8 mm Harmonic ACE Curved Shears, da Vinci Single-Site…Intuitive Surgical, Inc.2017—
−1K173337Intuitive Surgical EndoWrist Vessel Sealer ExtendIntuitive Surgical, Inc.20181
0 (this device)K183107Intuitive Surgical Vessel Sealer ExtendIntuitive Surgical, Inc.2018—
+1K191280E-100 Electrosurgical Generator, SynchroSealIntuitive Surgical, Inc.20192
+2K223039da Vinci E-200 Electrosurgical GeneratorIntuitive Surgical2022—
+3K231212da Vinci E-200 Electrosurgical GeneratorIntuitive Surgical2023—
+4K241635da Vinci E-200 Electrosurgical GeneratorIntuitive Surgical2024—
+5K253556da Vinci SP Surgical System (SP1098); da Vinci E-200 GeneratorIntuitive Surgical, Inc.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198110
198820
199010
199140
199240
199330
199480
1995100
199620
199760
199840
199920
200010
200180
200240
200320
200440
200520
200630
200730
200820
200930
201020
201120
201310
201410
201510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201910
202210
202310
202410
202510
202610
FIG. 1 — Lineage of K183107, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NAY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NAY device

  1. #1 K232610 da Vinci Surgical System Model IS5000, da…score 32.9 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K173337Intuitive Surgical EndoWrist Vessel Sealer Extend
Summary page 4
…nstrument Classification: Endoscope and accessories, 21 CFR 876.1500, NAY Predicate Device: Intuitive Surgical EndoWrist® Vessel Sealer Extend (K173337) P a g e 7-1…
Intuitive Surgical, Inc.20181

What descends from it? (6)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K191280E-100 Electrosurgical Generator, SynchroSealIntuitive Surgical, Inc.20194
K250674Vessel Sealer Curved (480522)Intuitive Surgical, Inc.20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 2 companies; a new generation was cleared every 1.2 years on median.
  • 24 of the 103 ancestors have a recall of any class.
  • Of its descendants, K191280 (Intuitive Surgical, Inc., 2019) has gone furthest, with 4 descendants of its own.

How does its category compare?

All NAY devices

NAY System, Surgical, Computer Controlled Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years. 2018, this device’s year, is highlighted.

FDA decisions per year · NAY

16in 2025

2008: 42009: 32010: 12011: 72012: 42013: 42014: 92015: 32016: 82017: 162018: 152019: 82020: 92021: 112022: 62023: 52024: 102025: 162026 (partial year): 7
2007high 16 (2017) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NAY

117in 2025

2008: 189 days median2009: 253 days median2011: 191 days median2012: 106 days median2013: 144 days median2014: 143 days median2015: 99 days median2016: 197 days median2017: 107 days median2018: 152 days median2019: 73 days median2020: 212 days median2021: 61 days median2022: 57 days median2023: 141 days median2024: 126 days median2025: 117 days median2026 (partial year): 89 days median
2007high 253 (2009) · low 57 (2022)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NAY

1in 2025

2007: 112008: 32009: 12011: 22012: 12013: 62014: 252015: 32016: 12017: 12018: 22019: 52021: 32022: 32023: 2, 1 Class I2024: 402025: 12026 (partial year): 4, 1 Class I
2007high 40 (2024) · low 0 (2010)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · NAY

48,456in 2025

2007: 1332008: 2242009: 3802010: 6232011: 5012012: 1,5522013: 6,2172014: 6,1352015: 1,7222016: 1,0772017: 1,0492018: 1,0742019: 1,1542020: 1,5582021: 1,9972022: 5,7272023: 10,8982024: 12,8722025: 48,456
2007high 48,456 (2025) · low 133 (2007)2025

MAUDE reports naming product code NAY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—11133
200841893224
200932531380
20101—0623
201171912501
2012410611,552
2013414466,217
20149143256,135
201539931,722
2016819711,077
20171610711,049
20181515221,074
201987351,154
2020921201,558
2021116131,997
202265735,727
202351412 (1)10,898
2024101264012,872
202516117148,456
20267894 (1)—

What is it indicated for?

Vessel Sealer Extend is a bipolar electrosurgical instrument for use with a compatible da Vinci Surgical System and a compatible electrosurgical generator. It is intended for grasping and blunt dissection of tissue and for bipolar coagulation and mechanical transection of vessels up to 7 mm in diameter and tissue bundles that fit in the jaws of the instrument. Vessel Sealer Extend has not been shown to be effective for tubal sterilization or tubal coagulation for sterilization procedures and should not be used for these procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K183107: Intuitive Surgical Vessel Sealer Extend.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K183107

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026