510(k) Report

510(k) · Cleared

Cleared

ProRad 2FC and ProRad 3NC Stationary Radiographic Systems

K183541510(k) TraditionalCleared Jan 24, 201935-day reviewClass II21 CFR 892.1680

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Prognosys Medical Systems Private Limited · KPR System, X-Ray, Stationary

Cleared on Jan 24, 2019 as substantially equivalent to K150816 (Sg Healthcare Co, Ltd., 2015) and 1 other predicate after a 35-day review. Its family tree reaches back 11 generations to 1980.

Decided
Jan 24, 2019
Review
35 days
Class
Class II
Product code
KPR
Recalls
None
Predicates
2

Its longest line of descent runs back 11 generations to K801623 (1980). 78 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2015: 1 other ancestor2014: 1 other ancestor2009: 1 other ancestor2007: 1 other ancestor2006: 2 other ancestors2004: 3 other ancestors2005: 1 other ancestor2003: 2 other ancestors2002: 7 other ancestors2001: 2 other ancestors1999: 4 other ancestors2000: 4 other ancestors1997: 4 other ancestors1995: 13 other ancestors1994: 2 other ancestors1998: 1 other ancestor1996: 4 other ancestors1993: 3 other ancestors1992: 2 other ancestors1989: 1 other ancestor1986: 1 other ancestor1991: 4 other ancestors1988: 2 other ancestors1981: 1 other ancestorReference device: K103591 · Digital Radiography · Canon Inc. -Medical Equipment Group · 2011Reference device: K171270 · Digital Radiography Cxdi-410C Wireless · Canon, Inc. · 2017Reference device: K131106 · Digital Radiography Cxdi-701C Wireless, Digital Radiography Cxdi-70IG Wireless, Digital Radiography Cxdi-801C Wireless, · Canon, Inc. · 2013Reference device: K170332 · Digital Radiography Cxdi-710C Wireless, Digital Radiography Cxdi-810C Wireless · Canon, Inc. · 2017Reference device: K172951 · Nexus DR Digital X-ray Imaging System (with PaxScan 4343RC and PaxScan 4343Rv3) · Varex Imaging Corporation · 2017Reference device: K161459 · Nexus DRTM Digital X-ray Imaging System (with PaxScan 4336Wv4) · Varian Medical Systems, X-Ray Products-Infimed · 2016Reference device: K142698 · PerkinElmer, XRpad 4343 F MED Flat Panel Detector · Perkinelmer, Inc. · 2014Reference device: K140551 · Perkinelmer, Xrpad 4336 Med Flat Panel Detector · Perkinelmer, Inc. · 2014Reference device: K162555 · Evs 4343, Evs 4343G · DRTECH Corporation · 2016Reference device: K162552 · Evs 3643, Evs 3643G · DRTECH Corporation · 2016Reference device: K153312 · Scatter Correction for Cxdi Series · Canon, Inc. · 2016Reference device: K130883 · Sedecal Digital Radiographic Upgrade Model Sdru-T · Sedecal., Sa. · 2013Reference device: K152172 · Econsole1 · DRTECH Corporation · 2015Reference device: K122865 · Vivix-S Wireless · Vieworks Co., Ltd. · 2013Reference device: K122866 · Vivix-S with Vxvue · Vieworks Co., Ltd. · 2013Reference device: K120020 · Vivix-S · Vieworks Co., Ltd. · 2012Reference device: K130318 · Nexus DRF Digital X-Ray Imaging System (with Paxscan 4343CB) · Varian Medical Systems, X-Ray Products-Infimed · 2013Reference device: K152767 · OTC12D Auto Radiographic System · Del Medical, Inc. · 2015Reference device: K173823 · Amrad Medical AAU Digital Radiography System; Amrad Medical AAU Plus Digital Radiography System; Amrad Medical DFMT Digital Radiography System; Amrad Medical FMT Digital Radiography System · Summit Industries, LLC · 2018Reference device: K103050 · DX-D 300 · Agfa Healthcare N.V. · 2010K801623 · Cavitron Ultrasonic Surg. Aspir. Cusa · Cavitron Corp. · 1980K962952 · Olympus Ultrasonic Surgical System (Usu) · Olympus Optical, Co. · 1996×2: 2 generations cleared close together, K972114 (1998), K981993 (1998) K994231 · Siemens Integrated Operating System (Sios) · Siemens Medical Corp. · 2000×2: 2 generations cleared close together, K052202 (2006), K061054 (2006) K062623 · Axiom Luminos DRF · Siemens Medical Solutions USA, Inc. · 2007 · recalledK081722 · YSIO · Siemens Medical Solutions USA, Inc. · 2008 · recalledK121513 · Multix Fusion · Siemens Medical Solution · 2012 · recalledK153119 · Amrad Medical OTS Digital Radiography System, Amrad Medical DFMTS Digital Radiography SystemAmrad Medical FRS Digital Radiography System, · Summit Industries, LLC · 201619801990200020102020
  1. Root · 11 generations backK801623 Cavitron Ultrasonic Surg. Aspir. CusaCavitron Corp. · 1980
  2. 7 generations between
  3. 3 generations backK081722 YSIOSiemens Medical Solutions USA, Inc. · 2008 · Recalled
  4. 2 generations backK121513 Multix FusionSiemens Medical Solution · 2012 · Recalled
  5. 1 generation backK153119 Amrad Medical OTS Digital Radiography System, Amrad Medical DFMTS…Summit Industries, LLC · 2016
  6. This deviceK183541 ProRad 2FC and ProRad 3NC Stationary Radiographic SystemsPrognosys Medical Systems Private Limited · 2019
Show all 11 generations
  1. Root · 11 generations backK801623 Cavitron Ultrasonic Surg. Aspir. CusaCavitron Corp. · 1980
  2. 10 generations backK962952 Olympus Ultrasonic Surgical System (Usu)Olympus Optical, Co. · 1996
  3. 9 generations backK972114 Olympus Sonosurg SystemThe Olympus Optical Co. · 1998
  4. 8 generations backK981993 Olympus Integrated Endosurgery System EndoalphaThe Olympus Optical Co. · 1998
  5. 7 generations backK994231 Siemens Integrated Operating System (Sios)Siemens Medical Corp. · 2000
  6. 6 generations backK052202 Axiom Artis - Modular Angiographic SystemSiemens Medical Solutions USA, Inc. · 2006 · Recalled
  7. 5 generations backK061054 Axiom Aristos FX PlusSiemens Medical Solutions USA, Inc. · 2006 · Recalled
  8. 4 generations backK062623 Axiom Luminos DRFSiemens Medical Solutions USA, Inc. · 2007 · Recalled
  9. 3 generations backK081722 YSIOSiemens Medical Solutions USA, Inc. · 2008 · Recalled
  10. 2 generations backK121513 Multix FusionSiemens Medical Solution · 2012 · Recalled
  11. 1 generation backK153119 Amrad Medical OTS Digital Radiography System, Amrad Medical DFMTS…Summit Industries, LLC · 2016
  12. This deviceK183541 ProRad 2FC and ProRad 3NC Stationary Radiographic SystemsPrognosys Medical Systems Private Limited · 2019
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−11K801623Cavitron Ultrasonic Surg. Aspir. CusaCavitron Corp.1980—
−10K962952Olympus Ultrasonic Surgical System (Usu)Olympus Optical, Co.1996—
−9K972114Olympus Sonosurg SystemThe Olympus Optical Co.1998—
−8K981993Olympus Integrated Endosurgery System EndoalphaThe Olympus Optical Co.1998—
−7K994231Siemens Integrated Operating System (Sios)Siemens Medical Corp.2000—
−6K052202Axiom Artis - Modular Angiographic SystemSiemens Medical Solutions USA, Inc.200629
−5K061054Axiom Aristos FX PlusSiemens Medical Solutions USA, Inc.20063
−4K062623Axiom Luminos DRFSiemens Medical Solutions USA, Inc.200720
−3K081722YSIOSiemens Medical Solutions USA, Inc.200811
−2K121513Multix FusionSiemens Medical Solution20124
−1K153119Amrad Medical OTS Digital Radiography System, Amrad Medical DFMTS Digital…Summit Industries, LLC2016—
0 (this device)K183541ProRad 2FC and ProRad 3NC Stationary Radiographic SystemsPrognosys Medical Systems Private Limited2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198110
198610
198820
198910
199140
199220
199330
199420
1995130
199640
199740
199810
199940
200040
200120
200270
200320
200430
200510
200620
200710
200910
201410
201510
FIG. 1 — Lineage of K183541, 1980–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KPR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KPR device

  1. #1 K242119 Innovision-Exiiscore 17.0 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K150816Jumong Series
Summary page 4
…lass: Class II Product Code: KPR, MQB Predicate Device: 1. Jumong Series Stationary Radiographic System (K150816) 2. Amrad Medical OTS Digital Radiography System, Amrad Medic…
Sg Healthcare Co, Ltd.2015—
*K153119Amrad Medical OTS Digital Radiography System, Amrad Medical DFMTS Digital Radiography…
Summary page 4
…Amrad Medical DFMTS Digital Radiography System, Amrad Medical FRS Digital Radiography System (K153119) Indications for Use: The ProRad Series Stationary Radiographic System is intended for use by a qualified, trained doctor or te…
Summit Industries, LLC2016—
†K103591Digital RadiographyCanon Inc. -Medical Equipment Group2011—
†K171270Digital Radiography Cxdi-410C WirelessCanon, Inc.2017—
†K131106Digital Radiography Cxdi-701C Wireless, Digital Radiography Cxdi-70IG Wireless, Digital…Canon, Inc.2013—
†K170332Digital Radiography Cxdi-710C Wireless, Digital Radiography Cxdi-810C WirelessCanon, Inc.2017—
†K172951Nexus DR Digital X-ray Imaging System (with PaxScan 4343RC and PaxScan 4343Rv3)Varex Imaging Corporation2017—
†K161459Nexus DRTM Digital X-ray Imaging System (with PaxScan 4336Wv4)Varian Medical Systems, X-Ray Products-Infimed2016—
†K142698PerkinElmer, XRpad 4343 F MED Flat Panel DetectorPerkinelmer, Inc.2014—
†K140551Perkinelmer, Xrpad 4336 Med Flat Panel DetectorPerkinelmer, Inc.2014—
†K162555Evs 4343, Evs 4343GDRTECH Corporation2016—
†K162552Evs 3643, Evs 3643GDRTECH Corporation2016—
†K153312Scatter Correction for Cxdi SeriesCanon, Inc.2016—
†K130883Sedecal Digital Radiographic Upgrade Model Sdru-TSedecal., Sa.2013—
†K152172Econsole1DRTECH Corporation2015—
†K122865Vivix-S WirelessVieworks Co., Ltd.2013—
†K122866Vivix-S with VxvueVieworks Co., Ltd.2013—
†K120020Vivix-SVieworks Co., Ltd.2012—
†K130318Nexus DRF Digital X-Ray Imaging System (with Paxscan 4343CB)Varian Medical Systems, X-Ray Products-Infimed2013—
†K152767OTC12D Auto Radiographic SystemDel Medical, Inc.2015—
†K173823Amrad Medical AAU Digital Radiography System; Amrad Medical AAU Plus Digital Radiography…Summit Industries, LLC2018—
†K103050DX-D 300Agfa Healthcare N.V.2010—
†K188187X-ray tube—

Also cleared against K150816: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 39 years and passes through 8 companies; a new generation was cleared every 2.0 years on median.
  • 22 of the 78 ancestors have a recall of any class.
  • 1 other device also cites its predicate K150816.

How does its category compare?

All KPR devices

KPR System, X-Ray, Stationary: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · KPR

8in 2025

2007: 122008: 152009: 92010: 92011: 92012: 112013: 52014: 102015: 182016: 112017: 62018: 152019: 122020: 162021: 62022: 82023: 92024: 112025: 82026 (partial year): 6
2007high 18 (2015) · low 5 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KPR

155in 2025

2007: 31 days median2008: 48 days median2009: 35 days median2010: 126 days median2011: 152 days median2012: 58 days median2013: 163 days median2014: 108 days median2015: 81 days median2016: 84 days median2017: 75 days median2018: 30 days median2019: 33 days median2020: 39 days median2021: 55 days median2022: 43 days median2023: 76 days median2024: 162 days median2025: 155 days median2026 (partial year): 197 days median
2007high 197 (2026) · low 30 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KPR

7in 2025

2007: 102008: 102009: 52010: 32011: 52012: 12013: 52014: 82015: 12016: 42017: 32018: 42019: 12020: 12022: 22023: 42024: 12025: 7
2007high 10 (2007) · low 0 (2021)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KPR

39in 2025

2007: 1202008: 952009: 612010: 822011: 1032012: 742013: 242014: 342015: 592016: 182017: 312018: 362019: 772020: 412021: 372022: 272023: 392024: 342025: 39
2007high 120 (2007) · low 18 (2016)2025

MAUDE reports naming product code KPR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007123110120
200815481095
2009935561
20109126382
201191525103
20121158174
20135163524
201410108834
20151881159
20161184418
2017675331
20181530436
20191233177
20201639141
2021655037
2022843227
2023976439
202411162134
20258155739
202661970—

What is it indicated for?

ProRad Series Stationary Radiographic System is intended for use by a qualified, trained doctor or technician on both adult and paediatric subjects for taking diagnostic radiographic exposures of the skull, spinal column, chest, abdomen, extremities, and other body parts. Applications can be performed with the patient sitting, standing, or lying in the prone or supine position. Not for mammography.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K183541: ProRad 2FC and ProRad 3NC Stationary Radiographic Systems.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K183541

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026