510(k) Report

510(k) · Cleared

Cleared

Atlas Multi-Drugs Screening Test Cup, Atlas Multi-Drugs Screening Test Panel

K191099510(k) TraditionalCleared Oct 3, 2019161-day reviewClass II21 CFR 862.3100

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Atlas Medical · DKZ Enzyme Immunoassay, Amphetamine

Cleared on Oct 3, 2019 as substantially equivalent to K153050 (Co-Innovation Biotech Co., Ltd., 2016) after a 161-day review. Its family tree reaches back 8 generations to 1995.

Decided
Oct 3, 2019
Review
161 days
Class
Class II
Product code
DKZ
Recalls
None
Predicates
1

Its longest line of descent runs back 8 generations to K945610 (1995). 30 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 8 generations backK945610 Abusign (TM) Amp, Doa-Amp, Accusign (TM) Amp-Doa-Amp, Biosign (TM)…Princeton BioMeditech Corp. · 1995
  2. 7 generations backK011673 Acon Amp One Step Amphetamine Test Strip, Acon Amp One Step…ACON Laboratories, Inc. · 2001
  3. 6 generations backK020313 Acon One Step Multi-Drug Multi-Line Screen Test Card; Acon One Step…Acon Laboratories Co. · 2002
  4. 5 generations backK031759 Acon Spectrum Multi-Drug Multi-Line Drug Screen Test Card and Acon…ACON Laboratories, Inc. · 2003 · Recalled
  5. 4 generations backK061718 Innovacon Spectrum II Test CardInnovacon, Inc. · 2006 · Recalled
  6. 3 generations backK122809 Advin Multi-Drug Screen Test Cassette, Dip Card and CupAdvin Biotech · 2013
  7. 2 generations backK140748 One Step Single/Multi-Drug Test Cup, One Step Single/Multi-Drug Test…Co-Innovation Biotech Co., Ltd. · 2014
  8. 1 generation backK153050 Rapid Single/Multi-drug Test Cup, Rapid Single/Multi-drug Test DipcardCo-Innovation Biotech Co., Ltd. · 2016
  9. This deviceK191099 Atlas Multi-Drugs Screening Test Cup, Atlas Multi-Drugs Screening…Atlas Medical · 2019
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K945610Abusign (TM) Amp, Doa-Amp, Accusign (TM) Amp-Doa-Amp, Biosign (TM) Amp, Doa-AmpPrinceton BioMeditech Corp.1995—
−7K011673Acon Amp One Step Amphetamine Test Strip, Acon Amp One Step Amphetamine Test…ACON Laboratories, Inc.2001—
−6K020313Acon One Step Multi-Drug Multi-Line Screen Test Card; Acon One Step Multi-Drug…Acon Laboratories Co.2002—
−5K031759Acon Spectrum Multi-Drug Multi-Line Drug Screen Test Card and Acon Spectrum…ACON Laboratories, Inc.20031
−4K061718Innovacon Spectrum II Test CardInnovacon, Inc.20066
−3K122809Advin Multi-Drug Screen Test Cassette, Dip Card and CupAdvin Biotech2013—
−2K140748One Step Single/Multi-Drug Test Cup, One Step Single/Multi-Drug Test DipcardCo-Innovation Biotech Co., Ltd.2014—
−1K153050Rapid Single/Multi-drug Test Cup, Rapid Single/Multi-drug Test DipcardCo-Innovation Biotech Co., Ltd.2016—
0 (this device)K191099Atlas Multi-Drugs Screening Test Cup, Atlas Multi-Drugs Screening Test PanelAtlas Medical2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199620
199810
199910
200010
200170
200220
200320
200430
200510
200610
201410
FIG. 1 — Lineage of K191099, 1995–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DKZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DKZ device

  1. #1 K233019 AllTest Multi-Drug Rapid Test Cup; AllTest…score 14.6 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K153050Rapid Single/Multi-drug Test Cup, Rapid Single/Multi-drug Test Dipcard
Summary page 6
…rugs Screening Tests (Cup and Panel Formats) has been determined to be substantially equivalent (Rapid Single/Multi-drug Test Cup, Rapid Single/Multi-drug Test Dipcard) (K 153050) currently in commercial distribution and manufactured by Co-innovation Biotech Co., ltd. (K153050). 4- Device description: 1)…
Co-Innovation Biotech Co., Ltd.2016—

Also cleared against K153050: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 7 companies; a new generation was cleared every 3.3 years on median.
  • 2 of the 30 ancestors have a recall of any class.
  • 4 other devices also cite its predicate K153050.

How does its category compare?

All DKZ devices

DKZ Enzyme Immunoassay, Amphetamine: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · DKZ

1in 2024

2008: 22009: 22010: 42011: 62012: 52013: 82014: 82015: 52016: 52018: 32019: 32020: 12023: 22024: 1
2007high 8 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DKZ

180in 2019

2010: 233 days median2011: 123 days median2012: 55 days median2013: 103 days median2014: 128 days median2015: 107 days median2016: 215 days median2018: 128 days median2019: 180 days median
2007high 233 (2010) · low 55 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DKZ

1in 2017

2007: 12008: 32009: 52011: 42013: 12014: 32017: 1
2007high 5 (2009) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DKZ

2in 2025

2008: 122009: 12010: 12011: 22013: 12014: 92015: 82016: 82021: 32022: 42023: 72024: 12025: 2
2007high 12 (2008) · low 0 (2007)2025

MAUDE reports naming product code DKZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—10
20082—312
20092—51
2010423301
2011612342
201255500
2013810311
2014812839
2015510708
2016521508
20170—10
2018312800
2019318000
20201—00
20210—03
20220—04
20232—07
20241—01
20250—02
20260—0—

What is it indicated for?

Atlas Multi-Drugs Screening Test Cup and Atlas Multi-Drugs Screening Test Panel are lateral flow chromatographic in vitro diagnostics immunoassays for the qualitative detection of following drugs in urine without the need of instruments: Drug Name Calibrator Cut-off Amphetamine (AMP) D-Amphetamine 1000 Methylenedioxymethamphetamine (MDMA) D,L Methylenedioxymethamphetamine 500 Morphine (MOP) Morphine 300 Morphine (MOP) Morphine 2000 Oxycodone (OXY)…

Read the full statement (221 words)

Atlas Multi-Drugs Screening Test Cup and Atlas Multi-Drugs Screening Test Panel are lateral flow chromatographic in vitro diagnostics immunoassays for the qualitative detection of following drugs in urine without the need of instruments:

Drug Name Calibrator Cut-off

Amphetamine (AMP) D-Amphetamine 1000

Methylenedioxymethamphetamine (MDMA) D,L Methylenedioxymethamphetamine 500

Morphine (MOP) Morphine 300

Morphine (MOP) Morphine 2000

Oxycodone (OXY) Oxycodone 100

Cocaine (COC) Benzoylecgonine 300

Nortriptyline Nortriptyline 1000

Methamphetamine (MET) D-Methamphetamine 1000

Phencyclidine (PCP) Phencyclidine 25

Marijuana (THC) 11-nor-Δ⁹-THC-9 COOH 50

Secobarbital Secobarbital 300

Oxazepam Oxazepam 300

Methadone (MTD) Methadone 300

Propoxyphene (PPX) Propoxyphene 300

Buprenorphine(BUP) Buprenorphine 10

The tests are intended for professional use only. The tests will yield preliminary positive results when the prescription drugs Secobarbital, oxazepam, Buprenorphine, Oxycodone, Propoxyphene, and Nortriptyline are ingested, even at or above therapeutic doses. There are no uniformly recognized drug levels for Secobarbital, oxazepam, Buprenorphine, Oxycodone, Propoxyphene, and Nortriptyline in urine. The multi-drugs screening tests (Cup and Panel formats) show the drug was or was not present at the cutoff level. The tests provide only preliminary test results, which must be confirmed by other methods such as gas chromatography/mass spectrometry (GC/MS). Clinical considerations and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated. The tests are not intended to be used in monitoring the drug levels.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K191099: Atlas Multi-Drugs Screening Test Cup, Atlas Multi-Drugs Screening Test Panel.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K191099

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026