510(k) · Cleared
Recalled · Class II · 202532mm Glenosphere and Humeral Cup
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Fx Shoulder USA, Inc. · PHX Shoulder Prosthesis, Reverse Configuration
Cleared on Oct 8, 2019 as substantially equivalent to K150488 (Fx Solutions, 2015) and 2 other predicates after a 55-day review. Its family tree reaches back 15 generations to 1991. 1 of the 126 devices in its family, counting itself, has a Class I recall. 4 later devices descend from it. It has been recalled once.
- Decided
- Oct 8, 2019
- Review
- 55 days
- Class
- Class II
- Product code
- PHX
- Recalls
- 1
- Predicates
- 3
Its longest line of descent runs back 15 generations to K911686 (1991). 121 ancestors in all, the oldest K790987 (1979). 4 later devices descend from it, 1 citing it directly. 1 of the 126 devices in this family, counting this one, has a Class I recall.
- Root · 15 generations backK911686 Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc. · 1991
- 11 generations between
- 3 generations backK112615 Aequalis Ascend Modular Reverse Shoulder SystemTornier, Inc. · 2011
- 2 generations backK122698 Aequalis Ascend Flex Shoulder SystemTornier S.A.S. · 2013 · Recalled
- 1 generation backK163669 Humeris ShoulderFx Solutions · 2017
- This deviceK192206 32mm Glenosphere and Humeral CupFx Shoulder USA, Inc. · 2019
- Descendant · cites it directly · 3 of its ownK193394 Humeral Cup Stability & Humeral Cup 135/145o StabilityFx Shoulder USA, Inc. · 2020
- Descendant · 2 generations on · 2 of its ownK223833 Exactech® Equinoxe® Reverse Humeral Liners and Humeral Adapter TraysExactech, Inc. · 2023 · Recalled
- Descendant · 3 generations on · 0 of its ownK260583 Equinoxe® Shoulder SystemExactech, Inc. · 2026
- Descendant · 3 generations on · 0 of its ownK243448 Equinoxe® Shoulder SystemExactech, Inc. · 2025
Show all 15 generations
- Root · 15 generations backK911686 Global Total Shoulder, Uncement Humeral Hemi-ShoulDepuy, Inc. · 1991
- 14 generations backK984541 Global FX Humeral Stem, Global Advantage Humeral HeadDePuy Orthopaedics, Inc. · 1999
- 13 generations backK992065 Global Advantage Shoulder, Global Advantage Humeral Stem, Global…DePuy Orthopaedics, Inc. · 1999
- 12 generations backK021478 Delta ShoulderDepuy, Inc. · 2003
- 11 generations backK030941 Aequalis Reversed Shoulder ProsthesisTornier · 2004
- 10 generations backK041873 Aequalis Reversed Shoulder ProsthesisTornier · 2004
- 9 generations backK052906 Zimmer Trabecular Metal Reverse Shoulder SystemZimmer, Inc. · 2005 · Recalled
- 8 generations backK060704 Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8MM and 10MMZimmer, Inc. · 2006 · Recalled
- 7 generations backK063569 Equinoxe Reverse Shoulder SystemExactech, Inc. · 2007 · Recalled
- 6 generations backK073688 Equinoxe Reverse Shoulder System Fracture Humeral Adapter Tray and…Exactech, Inc. · 2008 · Recalled
- 5 generations backK080642 Comprehensive Reverse ShoulderBiomet, Inc. · 2008 · Recalled (Class I)
- 4 generations backK110599 Aequalis Ascend Modular Reverse Shoulder SystemTornier, Inc. · 2011
- 3 generations backK112615 Aequalis Ascend Modular Reverse Shoulder SystemTornier, Inc. · 2011
- 2 generations backK122698 Aequalis Ascend Flex Shoulder SystemTornier S.A.S. · 2013 · Recalled
- 1 generation backK163669 Humeris ShoulderFx Solutions · 2017
- This deviceK192206 32mm Glenosphere and Humeral CupFx Shoulder USA, Inc. · 2019
Class I recalls in this family
- K080642 Comprehensive Reverse Shoulder5 generations back · 2008
Most influential descendants
Showing 4 of 4 · See all- K193394Humeral Cup Stability & Humeral Cup 135/145o StabilityFx Shoulder USA, Inc. · 2020 · cites it directly3descendants
- K223833Exactech® Equinoxe® Reverse Humeral Liners and Humeral Adapter TraysExactech, Inc. · 2023 · 2 generations on2descendants
- K260583Equinoxe® Shoulder SystemExactech, Inc. · 2026 · 3 generations on0descendants
- K243448Equinoxe® Shoulder SystemExactech, Inc. · 2025 · 3 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −15 | K911686 | Global Total Shoulder, Uncement Humeral Hemi-Shoul | Depuy, Inc. | 1991 | — |
| −14 | K984541 | Global FX Humeral Stem, Global Advantage Humeral Head | DePuy Orthopaedics, Inc. | 1999 | — |
| −13 | K992065 | Global Advantage Shoulder, Global Advantage Humeral Stem, Global Advantage… | DePuy Orthopaedics, Inc. | 1999 | — |
| −12 | K021478 | Delta Shoulder | Depuy, Inc. | 2003 | — |
| −11 | K030941 | Aequalis Reversed Shoulder Prosthesis | Tornier | 2004 | — |
| −10 | K041873 | Aequalis Reversed Shoulder Prosthesis | Tornier | 2004 | — |
| −9 | K052906 | Zimmer Trabecular Metal Reverse Shoulder System | Zimmer, Inc. | 2005 | 12 |
| −8 | K060704 | Zimmer Trabecular Metal Reverse Shoulder System, Sizes 8MM and 10MM | Zimmer, Inc. | 2006 | 10 |
| −7 | K063569 | Equinoxe Reverse Shoulder System | Exactech, Inc. | 2007 | 13 |
| −6 | K073688 | Equinoxe Reverse Shoulder System Fracture Humeral Adapter Tray and Locking Screw | Exactech, Inc. | 2008 | 1 |
| −5 | K080642 | Comprehensive Reverse Shoulder | Biomet, Inc. | 2008 | Class I |
| −4 | K110599 | Aequalis Ascend Modular Reverse Shoulder System | Tornier, Inc. | 2011 | — |
| −3 | K112615 | Aequalis Ascend Modular Reverse Shoulder System | Tornier, Inc. | 2011 | — |
| −2 | K122698 | Aequalis Ascend Flex Shoulder System | Tornier S.A.S. | 2013 | 2 |
| −1 | K163669 | Humeris Shoulder | Fx Solutions | 2017 | — |
| 0 (this device) | K192206 | 32mm Glenosphere and Humeral Cup | Fx Shoulder USA, Inc. | 2019 | — |
| +1 | K193394 | Humeral Cup Stability & Humeral Cup 135/145o Stability | Fx Shoulder USA, Inc. | 2020 | — |
| +2 | K223833 | Exactech® Equinoxe® Reverse Humeral Liners and Humeral Adapter Trays | Exactech, Inc. | 2023 | 1 |
| +3 | K260583 | Equinoxe® Shoulder System | Exactech, Inc. | 2026 | — |
| +3 | K243448 | Equinoxe® Shoulder System | Exactech, Inc. | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1979 | 1 | 0 |
| 1980 | 2 | 0 |
| 1986 | 1 | 0 |
| 1987 | 5 | 0 |
| 1988 | 1 | 0 |
| 1989 | 1 | 0 |
| 1991 | 2 | 0 |
| 1992 | 2 | 0 |
| 1993 | 1 | 0 |
| 1994 | 2 | 0 |
| 1995 | 4 | 0 |
| 1996 | 7 | 0 |
| 1997 | 2 | 0 |
| 1998 | 3 | 0 |
| 1999 | 6 | 0 |
| 2000 | 8 | 0 |
| 2001 | 7 | 0 |
| 2002 | 1 | 0 |
| 2003 | 6 | 0 |
| 2004 | 5 | 0 |
| 2005 | 7 | 0 |
| 2006 | 10 | 0 |
| 2007 | 5 | 0 |
| 2008 | 4 | 0 |
| 2009 | 1 | 0 |
| 2010 | 1 | 0 |
| 2011 | 3 | 0 |
| 2012 | 3 | 0 |
| 2013 | 2 | 0 |
| 2014 | 1 | 0 |
| 2015 | 1 | 0 |
| 2017 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2020 | 1 | 0 |
| 2023 | 1 | 0 |
| 2025 | 1 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new PHX device
- #1 K212737 INHANCE™ Reverse Shoulder Systemscore 28.4 · 15 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K150488 | Humelock II Reversible Shoulder SystemSummary page 5…sis — Class |l 21 CFR 888.3650: shoulder joint metal/polymer non- constrained cemented prosthesis — Class |l Primary Predicate: Humelock Il Reversible Shoulder System (K150488) Humelock Reversed Shoulder System (K162455) Humeris Shoulder System (K163669) Reference Device: DJO Surgical Reverse® Shoulder… | 2015 |
| * | K162455 | Humelock Reversed ShoulderSummary page 5…nt metal/polymer non- constrained cemented prosthesis — Class |l Primary Predicate: Humelock Il Reversible Shoulder System (K150488) Humelock Reversed Shoulder System (K162455) Humeris Shoulder System (K163669) Reference Device: DJO Surgical Reverse® Shoulder Prosthesis (RSP) (K092873) K… | 2017 |
| * | K163669 | Humeris ShoulderSummary page 5…cemented prosthesis — Class |l Primary Predicate: Humelock Il Reversible Shoulder System (K150488) Humelock Reversed Shoulder System (K162455) Humeris Shoulder System (K163669) Reference Device: DJO Surgical Reverse® Shoulder Prosthesis (RSP) (K092873) K192206 Page 2 of 4 Device Descrip… | 2017 |
| † | K092873 | Reverse Shoulder Prosthesis | 2009 |
What descends from it? (4)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K193394 | Humeral Cup Stability & Humeral Cup 135/145o Stability | 2020 | 3 |
Has anything in its family been recalled? (1 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Feb 19, 2025 | Class II | Z-1402-2025 | Software design | When following a specific less typical workflow in which the user remeasures using the ultrasound device or manually edits primitive or derived measurement values directly in Clinical Reporting, derived measurements may be inconsistent… |
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K080642Comprehensive Reverse ShoulderBiomet, Inc. · 2008 · 5 generations back · ◆ on the line of descent in FIG. 11 Class I recall
What does this lineage say?
- The line of descent spans 28 years and passes through 10 companies; a new generation was cleared every 1.0 years on median.
- 33 of the 121 ancestors have a recall of any class; 1 has a Class I recall.
- Of its descendants, K193394 (Fx Shoulder USA, Inc., 2020) has gone furthest, with 3 descendants of its own.
- 6 other devices also cite its predicate K150488.
How does its category compare?
All PHX devicesPHX Shoulder Prosthesis, Reverse Configuration: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.
FDA decisions per year · PHX
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · PHX
72in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · PHX
3in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · PHX
2,848in 2025
MAUDE reports naming product code PHX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 97 | 0 | 0 |
| 2008 | 6 | 79 | 0 | 0 |
| 2009 | 1 | — | 0 | 0 |
| 2010 | 8 | 124 | 0 | 0 |
| 2011 | 12 | 94 | 0 | 0 |
| 2012 | 12 | 114 | 0 | 0 |
| 2013 | 8 | 143 | 0 | 0 |
| 2014 | 12 | 110 | 0 | 0 |
| 2015 | 4 | 206 | 2 | 14 |
| 2016 | 4 | 132 | 0 | 5 |
| 2017 | 11 | 141 | 0 | 25 |
| 2018 | 14 | 127 | 1 | 323 |
| 2019 | 9 | 144 | 3 | 504 |
| 2020 | 13 | 143 | 3 | 986 |
| 2021 | 21 | 143 | 8 | 1,404 |
| 2022 | 9 | 198 | 0 | 1,342 |
| 2023 | 9 | 154 | 7 | 1,401 |
| 2024 | 9 | 139 | 1 | 2,142 |
| 2025 | 9 | 72 | 3 | 2,848 |
| 2026 | 18 | 130 | 7 | — |
What is it indicated for?
The Humelock II Reversible Shoulder is indicated for primary, fracture or revision total shoulder arthroplasty for the relief of pain and to improve function in patients with a massive and non-repairable rotator cuff tear. The patient’s joint must be anatomically and structuraly suited to receive the selected implants and a functional deltoid muscle is necessary to use the device. The humeral stems are intended for cemented or cementless use. The…
Read the full statement (441 words)
The Humelock II Reversible Shoulder is indicated for primary, fracture or revision total shoulder arthroplasty for the relief of pain and to improve function in patients with a massive and non-repairable rotator cuff tear.
The patient’s joint must be anatomically and structuraly suited to receive the selected implants and a functional deltoid muscle is necessary to use the device.
The humeral stems are intended for cemented or cementless use. The metaglene baseplate is intended for cementless use with the addition of screws for fixation.
The Humelock Reversed Shoulder System is indicated for primary, fracture or revision total shoulder arthroplasty for the relief of pain and to improve function in patients with a massive and non-repairable cuff tear.
The patient’s joint must be anatomically and structurally suited to receive the selected implants and a functional deltoid muscle is necessary to use the device.
During primary or revision surgery, if the glenoid bone stock appears to be insufficient to bear the reversed glenoid components or the glenoid bone fractures during the procedure, a taper adapter can be used to convert the Humelock Reversed Shoulder to an anatomic hemi-shoulder prosthesis.
The humeral stem of the Humelock Reversed Cemented Shoulder Prothesis is intended for cemented use only. The humeral stem of the Humelock Reversed Cementless Shoulder Prothesis is lockable with two cortical bone screws and is intended for cementless use only. An optional anti-rotational spoiler can be used with either the cementless or the cemented stems.
The glenoid baseplate and post extension are intended for cementless use with the addition of screws for fixation.
In an anatomic shoulder configuration, the Humeris Shoulder System is indicated for use in total and hemi-shoulder replacement to treat:
- A severely painful and/or disabled joint resulting from osteoarthritis or rheumatoid arthritis;
- Other difficult clinical problems where shoulder arthrodesis or resection arthroplasty are not acceptable (e.g. revision of a previously implanted primary component, a humeral plate or a humeral nail).
In a reverse shoulder configuration, the Humeris Shoulder is indicated for primary or revision total shoulder arthroplasty for the relief of pain and to improve function in patients with a massive and non-repairable rotator cuff tear.
The patient’s joint must be anatomically and structurally suited to receive the selected implants and a functional deltoid muscle is necessary to use the device.
The humeral stem of the Humeris Cementless Shoulder is intended for cementless use only. The humeral stem of the Humeris Cemented Shoulder is intended for cemented use only. The glenoid components of the Humeris Shoulder System are intended for cemented use only. The glenoid baseplate component is intended for cementless use with the addition of screws for fixation.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K192206 · printed Nov 6, 2026
Cite this page
510(k) Report. “K192206: 32mm Glenosphere and Humeral Cup.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K192206
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026