510(k) Report

510(k) · Cleared

Cleared

B. anthracis Real-time PCR Assay

K192871510(k) SpecialCleared Nov 7, 201930-day reviewClass II21 CFR 866.3045

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Centers for Disease Control and Prevention · NHT Assay, Nucleic Acid Amplification, Bacillus Anthracis

Cleared on Nov 7, 2019 as substantially equivalent to K140426 (Centers For Disease Control and Prevention (CDC), 2014) after a 30-day review. Its family tree reaches back 7 generations to 1993.

Decided
Nov 7, 2019
Review
30 days
Class
Class II
Product code
NHT
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K922906 (1993). 9 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 7 generations backK922906 Amplicor Chlamydia Trachomatis TestRoche Molecular Systems, Inc. · 1993
  2. 6 generations backK964506 Roche Cobas Amplicor AnalyzerRoche Molecular Systems, Inc. · 1997 · Recalled
  3. 5 generations backK012966 Roche Cobas Taqman AnalyzerRoche Molecular Systems, Inc. · 2002 · Recalled
  4. 4 generations backK033734 Lightcycler Instrument Version 1.2Roche Diagnostics Corp. · 2003 · Recalled
  5. 3 generations backK051713 Jbaids Anthrac Detection SystemIdaho Technology, Inc. · 2005
  6. 2 generations backK071188 Modification to Jbaids Anthrax Detection SystemIdaho Technology, Inc. · 2007
  7. 1 generation backK140426 Anthracis Real-Time PCR AssayCenters For Disease Control and Prevention (CDC) · 2014
  8. This deviceK192871 B. anthracis Real-time PCR AssayCenters for Disease Control and Prevention · 2019
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K922906Amplicor Chlamydia Trachomatis TestRoche Molecular Systems, Inc.1993—
−6K964506Roche Cobas Amplicor AnalyzerRoche Molecular Systems, Inc.19971
−5K012966Roche Cobas Taqman AnalyzerRoche Molecular Systems, Inc.20023
−4K033734Lightcycler Instrument Version 1.2Roche Diagnostics Corp.20031
−3K051713Jbaids Anthrac Detection SystemIdaho Technology, Inc.2005—
−2K071188Modification to Jbaids Anthrax Detection SystemIdaho Technology, Inc.2007—
−1K140426Anthracis Real-Time PCR AssayCenters For Disease Control and Prevention (CDC)2014—
0 (this device)K192871B. anthracis Real-time PCR AssayCenters for Disease Control and Prevention2019—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199510
FIG. 1 — Lineage of K192871, 1993–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NHT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K140426Anthracis Real-Time PCR Assay
Summary page 4
…on: (if applicable) detection; 21 CFR 866.3045 Predicate device(s): B. anthracis Real-time PCR Assay (K140426) Background Anthrax is a zoonotic disease caused by B. anthracis that is transmissible to humans through handli…
Centers For Disease Control and Prevention (CDC)2014—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 26 years and passes through 5 companies; a new generation was cleared every 3.9 years on median.
  • 4 of the 9 ancestors have a recall of any class.

How does its category compare?

All NHT devices

NHT Assay, Nucleic Acid Amplification, Bacillus Anthracis: FDA decisions, review times, recalls and adverse event reports over 20 years. 2019, this device’s year, is highlighted.

FDA decisions per year · NHT

1in 2019

2007: 22013: 12014: 12019: 12026 (partial year): 1
2007high 2 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NHT

Too few NHT 510(k)s in any year since 2007 to give a median.

Recalls per year · NHT

No recall names NHT since 2007.

Adverse event reports per year · NHT

1in 2021

2021: 1
2007high 1 (2021) · low 0 (2007)2025

MAUDE reports naming product code NHT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20080—00
20090—00
20100—00
20110—00
20120—00
20131—00
20141—00
20150—00
20160—00
20170—00
20180—00
20191—00
20200—00
20210—01
20220—00
20230—00
20240—00
20250—00
20261—0—

What is it indicated for?

The B. anthracis Real-Time PCR Assay is an in vitro diagnostic test for the qualitative detection of plasmid and chromosomal DNA sequences from B. anthracis. The assay can be used to test human respiratory samples, whole blood, serum, plasma, swabs from lesions, cerebrospinal fluid, pleural fluid, and bacterial culture isolates from individuals suspected of having anthrax. Results generated from direct specimen testing are presumptive for the…

Read the full statement (178 words)

The B. anthracis Real-Time PCR Assay is an in vitro diagnostic test for the qualitative detection of plasmid and chromosomal DNA sequences from B. anthracis. The assay can be used to test human respiratory samples, whole blood, serum, plasma, swabs from lesions, cerebrospinal fluid, pleural fluid, and bacterial culture isolates from individuals suspected of having anthrax.

Results generated from direct specimen testing are presumptive for the identification of B. anthracis. Results generated from culture isolate testing should be used in conjunction with other conventional methods for identification of Bacillus anthracis isolates as part of the LRN Bacillus anthracis Testing Algorithm. The diagnosis of anthrax infection must be made based on history, signs, symptoms, exposure likelihood, and other laboratory evidences, in addition to the identification of B. anthracis from cultures or detection directly in clinical specimens.

Use is limited to Laboratory Response Network (LRN) designated laboratories.

The B. anthracis Real-time PCR Assay is also intended for environmental specimen testing for biothreat detection and response. FDA has not evaluated claims related to the use of this assay on environmental specimens.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K192871: B. anthracis Real-time PCR Assay.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K192871

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026