510(k) Report

510(k) · Cleared

Cleared

3MTM AttestTM Rapid 5 Steam-Plus Test Pack

K200536510(k) TraditionalCleared Jun 1, 202090-day reviewClass II21 CFR 880.2800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

3M Complany · FRC Indicator, Biological Sterilization Process

Cleared on Jun 1, 2020 as substantially equivalent to K193154 (3M Company, 2020) after a 90-day review. Its family tree reaches back 6 generations to 1995.

Decided
Jun 1, 2020
Review
90 days
Class
Class II
Product code
FRC
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K926364 (1995). 10 ancestors in all, the oldest K900771 (1990). No later device cites it as a predicate yet.

  1. Root · 6 generations backK926364 Attest Brand Rapid Readout Biological Ind. #129X3M Health Care, Ltd. · 1995
  2. 5 generations backK090569 Modification to: Attest Rapid Readout Biological Indicator, Mode 12923M Company · 2009
  3. 4 generations backK121484 3M Attest (TM) Super Rapid Readout Biological Indicator, 3M Attest…3M Company · 2012
  4. 3 generations backK121593 3M Attest (TM) Super Radid Readout Steam Challenge Pack 3M Attest…3M Company · 2013
  5. 2 generations backK173519 3M Attest Super Rapid Readout Steam Challenge Pack, 3M Attest Super…3M Company · 2018 · Recalled
  6. 1 generation backK193154 3M Attest Super Rapid 5 Steam-Plus Challenge Pack3M Company · 2020 · Recalled
  7. This deviceK200536 3MTM AttestTM Rapid 5 Steam-Plus Test Pack3M Complany · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K926364Attest Brand Rapid Readout Biological Ind. #129X3M Health Care, Ltd.1995—
−5K090569Modification to: Attest Rapid Readout Biological Indicator, Mode 12923M Company2009—
−4K1214843M Attest (TM) Super Rapid Readout Biological Indicator, 3M Attest (TM)…3M Company2012—
−3K1215933M Attest (TM) Super Radid Readout Steam Challenge Pack 3M Attest (TM) Super…3M Company2013—
−2K1735193M Attest Super Rapid Readout Steam Challenge Pack, 3M Attest Super Rapid 5…3M Company20181
−1K1931543M Attest Super Rapid 5 Steam-Plus Challenge Pack3M Company20202
0 (this device)K2005363MTM AttestTM Rapid 5 Steam-Plus Test Pack3M Complany2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
199410
200210
201110
FIG. 1 — Lineage of K200536, 1995–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FRC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRC device

  1. #1 K250044 Celerity 5 HP Biological Indicator (LCB052)…score 14.5 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K1931543M Attest Super Rapid 5 Steam-Plus Challenge Pack
Summary page 5
…Sterilization Process [21 CFR § 880.2800(a), FRC] Predicate Device: 3M™ Attest™ Super Rapid 5 Steam-Plus Test Pack 41482V, K193154 Indications for Use: 3M™ Attest™ Rapid 5 Steam-Plus Test Pack 41382: Use the 3M™ Attest™ Rapid 5 Steam-Plus Test Pack 41382…
3M Company20202
†K771080Steam Sterilization IndicatorInfo-Chem1977—
†K090569Modification to: Attest Rapid Readout Biological Indicator, Mode 12923M Company2009—
†K1734373M Attest Super Rapid Readout Biological Indicator 1492V, 3M Attest Auto-reader 490, 3M…3M Company20181
†K1912363M™ Attest™ Steam Chemical Integrators3M Company2019—

Also cleared against K193154: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 3 companies; a new generation was cleared every 3.5 years on median.
  • 3 of the 10 ancestors have a recall of any class.
  • 2 other devices also cite its predicate K193154.

How does its category compare?

All FRC devices

FRC Indicator, Biological Sterilization Process: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · FRC

6in 2025

2007: 32008: 12009: 62010: 42011: 62012: 92013: 42014: 132015: 32016: 22017: 102018: 182019: 52020: 102021: 52022: 52023: 62024: 82025: 62026 (partial year): 1
2007high 18 (2018) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRC

29in 2025

2007: 83 days median2009: 183 days median2010: 165 days median2011: 118 days median2012: 178 days median2013: 260 days median2014: 174 days median2015: 130 days median2017: 130 days median2018: 97 days median2019: 88 days median2020: 150 days median2021: 107 days median2022: 193 days median2023: 190 days median2024: 105 days median2025: 29 days median
2007high 260 (2013) · low 29 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRC

8so far in 2026, the most since 2007

2009: 12012: 22013: 22022: 42023: 12026 (partial year): 8
2007high 8 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FRC

9in 2025

2007: 1002008: 602009: 452010: 572011: 372012: 462013: 392014: 512015: 1822016: 4822017: 1822018: 222019: 302020: 162021: 102022: 92023: 202024: 222025: 9
2007high 482 (2016) · low 9 (2022)2025

MAUDE reports naming product code FRC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073830100
20081—060
20096183145
20104165057
20116118037
20129178246
20134260239
201413174051
201531300182
20162—0482
2017101300182
20181897022
2019588030
202010150016
20215107010
2022519349
20236190120
20248105022
202562909
20261—8—

What is it indicated for?

3M™ Attest™ Rapid 5 Steam-Plus Test Pack 41382:

Use the 3M™ Attest™ Rapid 5 Steam-Plus Test Pack 41382 to qualify or monitor:

• 121°C (250°F) 30-minute gravity steam sterilization cycles;

• 132°C (270°F) 4-minute dynamic-air-removal steam sterilization cycles.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K200536: 3MTM AttestTM Rapid 5 Steam-Plus Test Pack.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K200536

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026