Attest Brand Rapid Readout Biological Indicator

K900771510(k) TraditionalCleared Jul 3, 1990133-day reviewClass II21 CFR 880.2800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

3M Company · FRC Indicator, Biological Sterilization Process

Cleared on Jul 3, 1990 after a 133-day review. FDA has not posted a summary or statement for it, so its predicates are not known. 36 later devices descend from it.

Decided
Jul 3, 1990
Review
133 days
Class
Class II
Product code
FRC
Recalls
None
Predicates
0

36 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2011: 1 descendant cleared2016: 2 descendants cleared2012: 1 descendant cleared2021: 2 descendants cleared2014: 1 descendant cleared2018: 9 descendants cleared2013: 1 descendant cleared2015: 1 descendant cleared2017: 3 descendants cleared2024: 5 descendants cleared2020: 8 descendants cleared2022: 2 descendants cleared1990200020102020
  1. This deviceK900771 Attest Brand Rapid Readout Biological Indicator3M Company · 1990
  2. Descendant · cites it directly · 35 of its ownK103277 3M Attest 1491 Super Rapid Readout Biological Indicator; 3M Attest…3M Company-3M Health Care · 2011 · Recalled
  3. Descendant · 2 generations on · 31 of its ownK121484 3M Attest (TM) Super Rapid Readout Biological Indicator, 3M Attest…3M Company · 2012
  4. Descendant · 2 generations on · 12 of its ownK140392 3M Attest Rapid Readout Biological Indicator / 3M Attest Auto-Reader3M Company · 2014
  5. Descendant · 3 generations on · 11 of its ownK152060 3M Attest Rapid Readout Biological Indicator 12953M Company · 2015
  6. Descendant · 3 generations on · 11 of its ownK121593 3M Attest (TM) Super Radid Readout Steam Challenge Pack 3M Attest…3M Company · 2013

Showing 5 of 36 descendants. See all descendants

Descendants cleared per year

2011: 12012: 12013: 12014: 12015: 12016: 22017: 32018: 92020: 82021: 22022: 22024: 5
2011high 9 (2018) · low 0 (2019)2026

Most influential descendants

Showing 5 of 36 · See all
  • K1032773M Attest 1491 Super Rapid Readout Biological Indicator; 3M Attest 490 Auto-Reader3M Company-3M Health Care · 2011 · cites it directly35descendants
  • K1214843M Attest (TM) Super Rapid Readout Biological Indicator, 3M Attest (TM) Auto-Reader3M Company · 2012 · 2 generations on31descendants
  • K1403923M Attest Rapid Readout Biological Indicator / 3M Attest Auto-Reader3M Company · 2014 · 2 generations on12descendants
  • K1520603M Attest Rapid Readout Biological Indicator 12953M Company · 2015 · 3 generations on11descendants
  • K1215933M Attest (TM) Super Radid Readout Steam Challenge Pack 3M Attest (TM) Super Rapid 5…3M Company · 2013 · 3 generations on11descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K900771Attest Brand Rapid Readout Biological Indicator3M Company1990—
+1K1032773M Attest 1491 Super Rapid Readout Biological Indicator; 3M Attest 490…3M Company-3M Health Care20111
+2K1214843M Attest (TM) Super Rapid Readout Biological Indicator, 3M Attest (TM)…3M Company2012—
+2K1403923M Attest Rapid Readout Biological Indicator / 3M Attest Auto-Reader3M Company2014—
+3K1520603M Attest Rapid Readout Biological Indicator 12953M Company2015—
+3K1215933M Attest (TM) Super Radid Readout Steam Challenge Pack 3M Attest (TM) Super…3M Company2013—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201210
201310
201410
201510
201620
201730
201890
202080
202120
202220
202450
FIG. 1 — Lineage of K900771, 1990–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FRC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRC device

  1. #1 K250044 Celerity 5 HP Biological Indicator (LCB052)…score 14.5 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it? (36)

See all 36

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K1032773M Attest 1491 Super Rapid Readout Biological Indicator; 3M Attest 490 Auto-Reader3M Company-3M Health Care201135

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K103277 (3M Company-3M Health Care, 2011) has gone furthest, with 35 descendants of its own.

How does its category compare?

All FRC devices

FRC Indicator, Biological Sterilization Process: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FRC

6in 2025

2007: 32008: 12009: 62010: 42011: 62012: 92013: 42014: 132015: 32016: 22017: 102018: 182019: 52020: 102021: 52022: 52023: 62024: 82025: 62026 (partial year): 1
2007high 18 (2018) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRC

29in 2025

2007: 83 days median2009: 183 days median2010: 165 days median2011: 118 days median2012: 178 days median2013: 260 days median2014: 174 days median2015: 130 days median2017: 130 days median2018: 97 days median2019: 88 days median2020: 150 days median2021: 107 days median2022: 193 days median2023: 190 days median2024: 105 days median2025: 29 days median
2007high 260 (2013) · low 29 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRC

8so far in 2026, the most since 2007

2009: 12012: 22013: 22022: 42023: 12026 (partial year): 8
2007high 8 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FRC

9in 2025

2007: 1002008: 602009: 452010: 572011: 372012: 462013: 392014: 512015: 1822016: 4822017: 1822018: 222019: 302020: 162021: 102022: 92023: 202024: 222025: 9
2007high 482 (2016) · low 9 (2022)2025

MAUDE reports naming product code FRC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073830100
20081—060
20096183145
20104165057
20116118037
20129178246
20134260239
201413174051
201531300182
20162—0482
2017101300182
20181897022
2019588030
202010150016
20215107010
2022519349
20236190120
20248105022
202562909
20261—8—
Cite this page

510(k) Report. “K900771: Attest Brand Rapid Readout Biological Indicator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K900771

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026